DOI | 10.1016/j.applthermaleng.2018.11.076 |
Influence of dry ambient conditions on performance of underground medium-voltage DC cables | |
Hruska, Marina1; Clauser, Christoph1; De Doncker, Rik W.2 | |
通讯作者 | Hruska, Marina |
来源期刊 | APPLIED THERMAL ENGINEERING
![]() |
ISSN | 1359-4311 |
出版年 | 2019 |
卷号 | 149页码:1419-1426 |
英文摘要 | In its publication IEC 60287, the International Electrotechnical Commission recommends procedures for thermal analysis of power cables in the presence of a dry-out zone in the surrounding medium. It is well known, that the ampacity of cables depends strongly on the so-called critical temperature at which the surrounding medium dries out. However, research on how to estimate this critical temperature has been limited. In semi-arid Mediterranean climate regions, dry summers typically lead to a decrease of the critical temperature. In this paper, the critical temperature is calculated for a field in Riverside, California under various ambient conditions. This is done from the numerical solution of the differential equation for moisture content in the planar case of steady-state coupled heat and mass transfer in porous media. Finite-difference simulations of a system of two medium-voltage DC cables in this field are performed with SHEMAT-Suite (Simulator of HEat and MAss Transport) to compute the maximum temperature for daily cases of calculated critical temperature and compared to a prediction from IEC 60287. It is found that large day-to-day variations in field conditions in a semi-arid area may significantly affect the maximum allowable current. Our results emphasize the importance of ambient conditions for the cable performance. |
英文关键词 | Heat transfer Soil drying Underground power cables Numerical simulation |
类型 | Article |
语种 | 英语 |
国家 | Germany |
收录类别 | SCI-E |
WOS记录号 | WOS:000460492300124 |
WOS关键词 | POWER-CABLES ; HYDRAULIC CONDUCTIVITY ; NUMERICAL-SIMULATION ; HEAT DISSIPATION ; THERMAL BACKFILL ; TEMPERATURE ; SOILS ; VAPOR ; WATER |
WOS类目 | Thermodynamics ; Energy & Fuels ; Engineering, Mechanical ; Mechanics |
WOS研究方向 | Thermodynamics ; Energy & Fuels ; Engineering ; Mechanics |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/214281 |
作者单位 | 1.Rhein Westfal TH Aachen, Inst Appl Geophys & Geothermal Energy GGE, FEN Res Campus, D-52074 Aachen, Germany; 2.Rhein Westfal TH Aachen, Inst Power Generat & Storage Syst PGS, FEN Res Campus, D-52074 Aachen, Germany |
推荐引用方式 GB/T 7714 | Hruska, Marina,Clauser, Christoph,De Doncker, Rik W.. Influence of dry ambient conditions on performance of underground medium-voltage DC cables[J],2019,149:1419-1426. |
APA | Hruska, Marina,Clauser, Christoph,&De Doncker, Rik W..(2019).Influence of dry ambient conditions on performance of underground medium-voltage DC cables.APPLIED THERMAL ENGINEERING,149,1419-1426. |
MLA | Hruska, Marina,et al."Influence of dry ambient conditions on performance of underground medium-voltage DC cables".APPLIED THERMAL ENGINEERING 149(2019):1419-1426. |
条目包含的文件 | 条目无相关文件。 |