Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1016/j.jchromb.2017.12.006 |
An improved liquid chromatography tandem mass spectrometry (LC-MS/MS) method method for quantification of dexmedetomidine concentrations in samples of human plasma | |
Moosavi, Seyed Mojtaba1; Shekar, Kiran2,3; Fraser, John F.2,3; Smith, Maree T.1,4; Ghassabian, Sussan1 | |
通讯作者 | Ghassabian, Sussan |
来源期刊 | JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
![]() |
ISSN | 1570-0232 |
EISSN | 1873-376X |
出版年 | 2018 |
卷号 | 1073页码:118-122 |
英文摘要 | Dexmedetomidine (DMET) is a sedative, analgesic and anxiolytic with minimum adverse respiratory effects. An LC-MS/MS bioanalytical method has been developed and validated to accurately measure DMET concentrations in samples of human plasma. The method overcomes difficulties in the extraction and quantification of DMET due to the fact that it binds strongly to glass and plastic tubes, as well as solid phase extraction (SPE) cartridges. Human plasma (50 mu L) was mixed with the internal standard (IS) (DMET-d4) solution (100 mu L) and 0.1% formic acid (50 mu L) and extracted using Oasis HLB 1 CC (30 mg) solid phase extraction (SPE) cartridges (Waters (R)). The glass tubes were coated with bovine serum albumin (BSA) 0.5% (20 mu L) before eluting DMET and the IS. After evaporation under nitrogen at room temperature, the analytes were reconstituted in 20% acetonitrile in 0.1% formic acid in water and transferred to silanized glass vials. An electrospray ionisation (ESI) mass spectrometry method in positive mode was created and the precursor/product transitions (m/z) were 201.1 -> 95.0 (DMET) and 204.9 -> 99.0 (IS). The method was robust and fully validated based on the 2012 EMEA guideline for bioanalytical method validation in the concentration range of 0.5-20 ng/mL. Using this assay, we showed that DMET binds strongly to Extracorporeal Membrane Oxygenation (ECMO) circuits, consistent with expectations for small lipophilic compounds. |
英文关键词 | Dexmedetomidine LC MS/MS Bioanalysis Method development Validation Solid phase extraction (SPE) |
类型 | Article |
语种 | 英语 |
国家 | Australia |
收录类别 | SCI-E |
WOS记录号 | WOS:000423889300015 |
WOS关键词 | EXTRACORPOREAL MEMBRANE-OXYGENATION ; QUANTITATION |
WOS类目 | Biochemical Research Methods ; Chemistry, Analytical |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/210727 |
作者单位 | 1.Univ Queensland, Ctr Integrated Preclin Drug Dev, Brisbane, Qld, Australia; 2.Prince Charles Hosp, Adult Intens Care Serv, Crit Care Res Grp, Brisbane, Qld, Australia; 3.Univ Queensland, Brisbane, Qld, Australia; 4.Univ Queensland, Sch Pharm, Brisbane, Qld, Australia |
推荐引用方式 GB/T 7714 | Moosavi, Seyed Mojtaba,Shekar, Kiran,Fraser, John F.,et al. An improved liquid chromatography tandem mass spectrometry (LC-MS/MS) method method for quantification of dexmedetomidine concentrations in samples of human plasma[J],2018,1073:118-122. |
APA | Moosavi, Seyed Mojtaba,Shekar, Kiran,Fraser, John F.,Smith, Maree T.,&Ghassabian, Sussan.(2018).An improved liquid chromatography tandem mass spectrometry (LC-MS/MS) method method for quantification of dexmedetomidine concentrations in samples of human plasma.JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES,1073,118-122. |
MLA | Moosavi, Seyed Mojtaba,et al."An improved liquid chromatography tandem mass spectrometry (LC-MS/MS) method method for quantification of dexmedetomidine concentrations in samples of human plasma".JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES 1073(2018):118-122. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。