Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1016/j.jchromb.2017.12.008 |
Development of an LC-MS method to quantify coproporphyrin I and III as endogenous biomarkers for drug transporter-mediated drug-drug interactions | |
Ediage, Emmanuel Njumbe; Dillen, Lieve; Vroman, Ann; Diels, Luc; Kunze, Annett; Snoeys, Jan; Verhaeghe, Tom | |
通讯作者 | Ediage, Emmanuel Njumbe |
来源期刊 | JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
![]() |
ISSN | 1570-0232 |
EISSN | 1873-376X |
出版年 | 2018 |
卷号 | 1073页码:80-89 |
英文摘要 | Coproporphyrins are proposed as endogenous biomarkers of hepatic Organic Anion Transporting Polypeptide (OATP)1 B functional activity. In this study, a new sample extraction method based on a mixed-mode anion exchange sorbent (SPE clean-up using Oasis 30 mg Max 96 well plates) was developed for absolute quantification of coproporphyrin I and III (CP-I and CP-III) in human plasma. Chromatographic separation was performed with an Ace Excel 2 C18 PFP, 3 gm, 2.1 x 150 mm, maintained at 60 degrees C. A 10 mM ammonium formate containing 0.1% HCOOH and acetonitrile (100%) was used as mobile phase A and B, respectively. Mass transition, m/z 655.3 -> 596.3 was selected to monitor CP-I and CP-III, while m/z 659.3 -> 600.3 transition was used for the stable isotope labelled internal standard. Optimization of the liquid chromatography tandem mass spectrometry method ensured a lower limit of quantification (LLOQ) of 20 pg/mL. Both CP-I and CP-III had extraction recoveries of 70%. The calibration range was 0.02-100 ng/mL for both CP-I and CP-III, yielding calibration curves with correlation coefficients greater than 0.988. Inter day precision (CV < 9%) and accuracy (84.3-103.9%) complied with the recommendation of the European Bioanalytical Forum. The optimized method was used to analyse plasma samples originating from three independent clinical studies. Obtained CP-I and CP-III plasma baseline levels in healthy volunteers were in good agreement with previously published data. Moreover, CP-I and CP-III plasma levels in human subjects dosed with a clinically confirmed OATP inhibitor were significantly increased compared to their baseline levels. These data demonstrate the potential of CP-I and CP-III as endogenous biomarkers to predict the drug-drug interaction (DDI) related to hepatic OATP1 B inhibition. Stability of CP-I and CP-Ill in plasma and solvents under different processing and storage conditions was also evaluated. |
英文关键词 | Coproporphyrin Endogenous biomarker Light stability sensitive LC-MS/MS OATP1B Oasis MAX SPE |
类型 | Article |
语种 | 英语 |
国家 | Belgium |
收录类别 | SCI-E |
WOS记录号 | WOS:000423889300010 |
WOS关键词 | TANDEM MASS-SPECTROMETRY ; CAPILLARY-ELECTROPHORESIS ; LIQUID-CHROMATOGRAPHY ; URINARY PORPHYRINS ; ENHANCED DETECTION ; INHIBITION ; PLASMA ; QUANTIFICATION ; RECOMMENDATION ; SEPARATION |
WOS类目 | Biochemical Research Methods ; Chemistry, Analytical |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/210726 |
作者单位 | Janssen Res & Dev, Pharmacokinet Dynam & Metab, Turnhoutseweg 30, Beerse, Belgium |
推荐引用方式 GB/T 7714 | Ediage, Emmanuel Njumbe,Dillen, Lieve,Vroman, Ann,et al. Development of an LC-MS method to quantify coproporphyrin I and III as endogenous biomarkers for drug transporter-mediated drug-drug interactions[J],2018,1073:80-89. |
APA | Ediage, Emmanuel Njumbe.,Dillen, Lieve.,Vroman, Ann.,Diels, Luc.,Kunze, Annett.,...&Verhaeghe, Tom.(2018).Development of an LC-MS method to quantify coproporphyrin I and III as endogenous biomarkers for drug transporter-mediated drug-drug interactions.JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES,1073,80-89. |
MLA | Ediage, Emmanuel Njumbe,et al."Development of an LC-MS method to quantify coproporphyrin I and III as endogenous biomarkers for drug transporter-mediated drug-drug interactions".JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES 1073(2018):80-89. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。