Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1016/j.chroma.2018.02.057 |
A method for analysis of marker persistent organic pollutants in low-volume plasma and serum samples using 96-well plate solid phase extraction | |
Stubleski, Jordan1; Kukucka, Petr2; Salihovic, Samira1,3; Lind, P. Monica4; Lind, Lars5; Karrman, Anna1 | |
通讯作者 | Stubleski, Jordan |
来源期刊 | JOURNAL OF CHROMATOGRAPHY A
![]() |
ISSN | 0021-9673 |
EISSN | 1873-3778 |
出版年 | 2018 |
卷号 | 1546页码:18-27 |
英文摘要 | The objective of this study was to develop and validate a 96-well plate solid phase extraction method for analysis of 23 lipophilic persistent organic pollutants (POPs) in low-volume plasma and serum samples which is applicable for biomonitoring and epidemiological studies. The analysis of selected markers for internal exposure: 16 polychlorinated biphenyls (PCBs), 5 organochlorine pesticides (OCPs), octachlorinated dibenzo-p-dioxin (OCDD), and polybrominated diphenylether 47 (BDE 47) was evaluated by comparing two SPE sorbents and GC-HRMS or GC-MS/MS detection. The final method extracted 23 POPs from 150 mu L of serum and plasma using a 96-well extraction plate containing 60 mg Oasis HLB sorbent per well prior to GC-HRMS magnetic sector analysis. The extraction method was applied to 40 plasma samples collected for an epidemiological study. The recovery of selected POPs ranged from 31% to 63% (n = 48), and detection limits ranged from 2.2 to 45 pg/mL for PCBs, 4.2 to 167 pg/mL for OCPs, 7.8 pg/mL for OCDD and 6.1 pg/mL for BDE 47. This method showed good precision with relative standard deviations of selected POP concentrations in quality control samples (n = 48) ranging from 11% to 25%. The trueness was determined with standard reference material serum (n = 48) and the deviation from certified values ranged from 1 to 27%. Of the 23 POPs analyzed, 18 were detected in 43% to 100% of plasma samples collected for the epidemiological study. The method showed good robustness with low inter-well plate variation (11-31%) determined by twelve 96-well plate extractions, and can extract 96 samples, including quality controls and procedural blanks in 2-3 days. Comparison with GC-MS/MS analysis showed that similar concentrations (within 0.5% to 30%) of most POPs could be obtained with GC-APCI-MS/MS. Larger deviations were observed for PCB 194 (60%) and trans-nonachlor (43%). The developed method produces accurate concentrations of low-level marker POPs in plasma and serum, providing a suitable high-throughput sample preparation procedure for biomonitoring and epidemiological studies involving large sample size and limited sample volume. GC-HRMS was chosen over GC-MS/MS, however the latter showed promising results, and could be used as an alternative to GC-HRMS analysis for most POPs. (C) 2018 Elsevier B.V. All rights reserved. |
英文关键词 | High-throughput SPE Persistent organic pollutants GC-HRMS APCI-MS/MS |
类型 | Article |
语种 | 英语 |
国家 | Sweden ; Czech Republic |
收录类别 | SCI-E |
WOS记录号 | WOS:000430766800003 |
WOS关键词 | POLYBROMINATED DIPHENYL ETHERS ; POLYCHLORINATED-BIPHENYLS ; ORGANOCHLORINE PESTICIDES ; ADIPOSE-TISSUE ; HUMAN BLOOD ; POPS ; ASSOCIATION ; HRGC/HRMS ; DIOXINS ; TRENDS |
WOS类目 | Biochemical Research Methods ; Chemistry, Analytical |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/210719 |
作者单位 | 1.Orebro Univ, Sch Sci & Technol, MTM, S-70182 Orebro, Sweden; 2.Masaryk Univ, RECETOX, Kamenice 5, Brno 62500, Czech Republic; 3.Uppsala Univ, Dept Med Sci, Mol Epidemiol & Sci Life Lab, S-75141 Uppsala, Sweden; 4.Uppsala Univ, Dept Med Sci Occupat & Environm Med, Uppsala, Sweden; 5.Uppsala Univ, Dept Med Sci, Cardiovasc Epidemiol, Uppsala, Sweden |
推荐引用方式 GB/T 7714 | Stubleski, Jordan,Kukucka, Petr,Salihovic, Samira,et al. A method for analysis of marker persistent organic pollutants in low-volume plasma and serum samples using 96-well plate solid phase extraction[J],2018,1546:18-27. |
APA | Stubleski, Jordan,Kukucka, Petr,Salihovic, Samira,Lind, P. Monica,Lind, Lars,&Karrman, Anna.(2018).A method for analysis of marker persistent organic pollutants in low-volume plasma and serum samples using 96-well plate solid phase extraction.JOURNAL OF CHROMATOGRAPHY A,1546,18-27. |
MLA | Stubleski, Jordan,et al."A method for analysis of marker persistent organic pollutants in low-volume plasma and serum samples using 96-well plate solid phase extraction".JOURNAL OF CHROMATOGRAPHY A 1546(2018):18-27. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。