Arid
DOI10.25165/j.ijabe.20181101.2479
New control strategy against temperature sudden-drop in the initial stage of pad cooling process in poultry houses
Hui, Xue1,2,3; Li, Baoming1,2; Xin, Hongwei4; Zheng, Weichao1,2; Shi, Zhengxiang1,2; Yang, Xiao1,2; Zhao, Shumei1,2
通讯作者Zhao, Shumei
来源期刊INTERNATIONAL JOURNAL OF AGRICULTURAL AND BIOLOGICAL ENGINEERING
ISSN1934-6344
EISSN1934-6352
出版年2018
卷号11期号:1页码:66-73
英文摘要

Preliminary field measurements have shown substantial temperature sudden-drop (Delta T-sd) at bird level in the initial stage of pad cooling process in arid regions of China. Such sudden temperature fluctuation can cause thermal stress to laying hens and this problem is attracting increasing concerns. The purpose of this study was to develop a new control strategy (NCS) to avoid or minimize Delta T-sd while simplifying the operational process. Theoretical calculation and field test were conducted in this study. The key ambient thermal factor affecting Delta T-sd was analysed by calculating temperature drop of cooled air existing the cooling pad (Delta T-sd). A countermeasure was applied by controlling the wetted pad area at each startup of the water supply pump. Field test was carried out to demonstrate the application of the NCS in a poultry house. The theoretical arithmetic results showed that ambient relative humidity (RHo) was the main factor affecting Delta T-d, and Delta T-sd occurred when RHo <= 60%. Temperature fluctuation at the bird level (T-db,(b)) could be controlled within 4 degrees C when the wetted pad area increased by 25%. The NCS operated based on RHo that was divided into three regions. For RHo <= 80%, the pump would not be turned on because of poor cooling effect. For 60% < RHo < 80%, no Delta T-sd would occur and the pump would be controlled by "on-off" regulation. For RHo <= 60%, Delta T-sd occurred and the pump was turned on intermittently. Then, 4-stage cooling would be applied. Results of the field test were generally consistent with the theoretical simulation with regards to alleviation of Delta T-sd that was controlled within 3.5 degrees C. Further field verification of the NCS on the flock health and production performance is warranted.


英文关键词evaporative cooling poultry housing new control strategy temperature fluctuation thermal stress
类型Article
语种英语
国家Peoples R China ; USA
收录类别SCI-E
WOS记录号WOS:000425030800007
WOS关键词AMBIENT-TEMPERATURE ; EGG-PRODUCTION ; SYSTEM ; SUITABILITY ; CHINA
WOS类目Agricultural Engineering
WOS研究方向Agriculture
来源机构中国农业大学
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/210108
作者单位1.China Agr Univ, Coll Water Resources & Civil Engn, Key Lab Agr Engn Struct & Environm, Minist Agr, Beijing 100083, Peoples R China;
2.Beijing Engn Res Ctr Anim Hlth Environm, Beijing 100083, Peoples R China;
3.Henan Univ Anim Husb & Econ, Coll Automat, Zhengzhou 450011, Henan, Peoples R China;
4.Iowa State Univ, Dept Agr & Biosyst Engn, Ames, IA 50011 USA
推荐引用方式
GB/T 7714
Hui, Xue,Li, Baoming,Xin, Hongwei,et al. New control strategy against temperature sudden-drop in the initial stage of pad cooling process in poultry houses[J]. 中国农业大学,2018,11(1):66-73.
APA Hui, Xue.,Li, Baoming.,Xin, Hongwei.,Zheng, Weichao.,Shi, Zhengxiang.,...&Zhao, Shumei.(2018).New control strategy against temperature sudden-drop in the initial stage of pad cooling process in poultry houses.INTERNATIONAL JOURNAL OF AGRICULTURAL AND BIOLOGICAL ENGINEERING,11(1),66-73.
MLA Hui, Xue,et al."New control strategy against temperature sudden-drop in the initial stage of pad cooling process in poultry houses".INTERNATIONAL JOURNAL OF AGRICULTURAL AND BIOLOGICAL ENGINEERING 11.1(2018):66-73.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Hui, Xue]的文章
[Li, Baoming]的文章
[Xin, Hongwei]的文章
百度学术
百度学术中相似的文章
[Hui, Xue]的文章
[Li, Baoming]的文章
[Xin, Hongwei]的文章
必应学术
必应学术中相似的文章
[Hui, Xue]的文章
[Li, Baoming]的文章
[Xin, Hongwei]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。