Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1109/JSTARS.2018.2862638 |
Radiometric Cross-Calibration of Landsat-8/OLI and GF-1/PMS Sensors Using an Instrumented Sand Site | |
Zhao, Yongguang; Ma, Lingling; Li, Chuanrong; Gao, Caixia; Wang, Ning; Tang, Lingli | |
通讯作者 | Ma, Lingling |
来源期刊 | IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING
![]() |
ISSN | 1939-1404 |
EISSN | 2151-1535 |
出版年 | 2018 |
卷号 | 11期号:10页码:3822-3829 |
英文摘要 | The panchromatic and multispectral (PMS1/PMS2) sensors designed with one panchromatic band and four multispectral bands are two optical cameras on-board the Gao Fen 1 (GF-1) satellite launched on April 26, 2013. The spatial resolution of PMS1/PMS2are 2 and 8 m of pan and multispectral, respectively. The vicarious calibration of GF-1/PMS was performed by China Centre for Resource Satellite Data and Application, and the calibration coefficients were released once a year. Due to the lack of on-board calibrator, the on-orbit radiometric performance evaluation of the PMS sensors is very important for the further quantitative application of the data. To evaluate the radiometric performance of PMS1 sensor on-board GF-1 satellite, this paper attempts to calibrate PMS1 sensor against the well-calibrated OLI sensor on-board Landsat-8. An instrumented sand site was used, which is located in the national high resolution remote sensing comprehensive calibration site, Baotou, China. The cross-calibration coefficients of PMS1 on October 5, 2015 and August 20, 2016 are calculated and compared with the official calibration coefficients published in 2015 and 2016. The results show that the cross-calibration of PMS sensor using other sensors is necessary, due to the low updating frequency of calibration coefficient for GF-1/PMS sensor. The uncertainty estimation results show that the total uncertainties associated with the cross-calibration of Landsat-8/OLI and GF-1/PMS sensors over a desert site are within 5.5%. |
英文关键词 | Cross-calibration GF-1/PMS Landsat-8/OLI reflective solar band |
类型 | Article |
语种 | 英语 |
国家 | Peoples R China |
收录类别 | SCI-E |
WOS记录号 | WOS:000447950200037 |
WOS类目 | Engineering, Electrical & Electronic ; Geography, Physical ; Remote Sensing ; Imaging Science & Photographic Technology |
WOS研究方向 | Engineering ; Physical Geography ; Remote Sensing ; Imaging Science & Photographic Technology |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/209978 |
作者单位 | Chinese Acad Sci, Acad Optoelect, Key Lab Quantitat Remote Sensing Informat Technol, Beijing 100094, Peoples R China |
推荐引用方式 GB/T 7714 | Zhao, Yongguang,Ma, Lingling,Li, Chuanrong,et al. Radiometric Cross-Calibration of Landsat-8/OLI and GF-1/PMS Sensors Using an Instrumented Sand Site[J],2018,11(10):3822-3829. |
APA | Zhao, Yongguang,Ma, Lingling,Li, Chuanrong,Gao, Caixia,Wang, Ning,&Tang, Lingli.(2018).Radiometric Cross-Calibration of Landsat-8/OLI and GF-1/PMS Sensors Using an Instrumented Sand Site.IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING,11(10),3822-3829. |
MLA | Zhao, Yongguang,et al."Radiometric Cross-Calibration of Landsat-8/OLI and GF-1/PMS Sensors Using an Instrumented Sand Site".IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING 11.10(2018):3822-3829. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。