Arid
DOI10.1016/j.legalmed.2016.11.005
Rapid and highly sensitive analysis of benzodiazepines and tandospirone in human plasma by automated on-line column-switching UFLC-MS/MS
Lee, Xiao-Pen1; Shouji, Yukiko1; Kumazawa, Takeshi1,2; Hasegawa, Chika3; Fujishiro, Masaya1; Sato, Junichi1; Hasegawa, Iwao4; Sato, Keizo1
通讯作者Lee, Xiao-Pen
来源期刊LEGAL MEDICINE
ISSN1344-6223
出版年2017
卷号24页码:36-55
英文摘要

A high-throughput method was developed for the detection of 31 benzodiazepine drugs and tandospirone in human plasma by on-line column-switching ultra-fast liquid chromatography-tandem mass spectrometry. Plasma samples (100 mu 1) spiked with the 32 drugs and oxazepam-d(5) (internal standard) were diluted with 300 mu 1 of 13.3 mM ammonium acetate/acetonitrile (33:67, v/v). After centrifugation and filtration, the clear supernatant was injected directly onto the extraction column (Oasis HLB cartridge column). The following procedure was fully automated. The analytes retained on the extraction column were eluted by backflushing of the extraction column and introduced into an analytical column (SUMIPAX ODS D-Swifter column, 30 mm x 3.0 mm i.d.; particle size 21.1m) by column switching. Quantification was performed by multiple reaction monitoring with positive-ion electrospray ionization. Distinct peaks appeared for each drug and the internal standard on each channel within 7 min, including the extraction time. All drugs spiked into plasma showed recoveries of 83-95%. The regression equations for the 32 drugs showed excellent linearities in the range of 50-2000 pg/ml of plasma and the limits of detection ranged from 20 to 50 pgiml. The lower and upper limits of quantitation were 50-100 ng/m1 and 2000 peril, respectively. Intra- and interday coefficients of variation for none of the drugs were greater than 13.6%. The accuracies of quantitation were 87-112%. The multiple reaction monitoring information dependent acquisition of enhanced product ions method enabled the quantification and confirmation of diazepam, triazolam, and lorazepam obtained from actual plasma. (C) 2016 Elsevier Ireland Ltd. All rights reserved.


英文关键词Benzodiazepine drugs Tandospirone SUMIPAX ODS D-Swifter column On-line column switching UFLC-MS/MS Human plasma
类型Article
语种英语
国家Japan
收录类别SCI-E
WOS记录号WOS:000393010700007
WOS关键词PERFORMANCE LIQUID-CHROMATOGRAPHY ; TANDEM MASS-SPECTROMETRY ; GAS-CHROMATOGRAPHY ; WHOLE-BLOOD ; URINE ; METABOLITES ; DRUGS ; IMMUNOASSAY ; COMBINATION ; VALIDATION
WOS类目Medicine, Legal ; Social Sciences, Biomedical
WOS研究方向Legal Medicine ; Biomedical Social Sciences
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/201004
作者单位1.Showa Univ, Dept Legal Med, Sch Med, Tokyo 1428555, Japan;
2.Seirei Christopher Univ, Sch Nursing, Shizuoka 4338558, Japan;
3.Toho Univ, Dept Legal Med, Sch Med, Tokyo 1438540, Japan;
4.Kanagawa Dent Univ, Univ Ctr Legal Med, Kanagawa 2388580, Japan
推荐引用方式
GB/T 7714
Lee, Xiao-Pen,Shouji, Yukiko,Kumazawa, Takeshi,et al. Rapid and highly sensitive analysis of benzodiazepines and tandospirone in human plasma by automated on-line column-switching UFLC-MS/MS[J],2017,24:36-55.
APA Lee, Xiao-Pen.,Shouji, Yukiko.,Kumazawa, Takeshi.,Hasegawa, Chika.,Fujishiro, Masaya.,...&Sato, Keizo.(2017).Rapid and highly sensitive analysis of benzodiazepines and tandospirone in human plasma by automated on-line column-switching UFLC-MS/MS.LEGAL MEDICINE,24,36-55.
MLA Lee, Xiao-Pen,et al."Rapid and highly sensitive analysis of benzodiazepines and tandospirone in human plasma by automated on-line column-switching UFLC-MS/MS".LEGAL MEDICINE 24(2017):36-55.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Lee, Xiao-Pen]的文章
[Shouji, Yukiko]的文章
[Kumazawa, Takeshi]的文章
百度学术
百度学术中相似的文章
[Lee, Xiao-Pen]的文章
[Shouji, Yukiko]的文章
[Kumazawa, Takeshi]的文章
必应学术
必应学术中相似的文章
[Lee, Xiao-Pen]的文章
[Shouji, Yukiko]的文章
[Kumazawa, Takeshi]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。