Arid
DOI10.1080/10826076.2017.1315722
Automated SPE and nanoLC-MS analysis of somatostatin
Maasz, Gabor1,2; Schmidt, Janos1; Avar, Peter1; Mark, Laszlo1,3,4,5
通讯作者Maasz, Gabor
来源期刊JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES
ISSN1082-6076
EISSN1520-572X
出版年2017
卷号40期号:8页码:400-406
英文摘要

Plasma peptides are widely used in clinical diagnosis and therapy monitoring. Our aim was an efficient system development for the enrichment of small, low abundant peptides from plasma by robotized sample preparation. The automation of SPE yields additional time saving and improves system robustness and repeatability. Automation is based on combining a Waters SPE kit with Oasis HLB sorbent and a multichannel liquid handling workstation with cheap commercially available electronic devices such as a programmable logic controller (PLC) and an AVR controller. Reversed phase nano liquid chromatography coupled with a sensitive quadrupole time of flight mass spectrometer (QTOF MS) was used for the quantitative determination of somatostatin (SST). We quantified SST from mouse plasma, where lower limit of detection (LLOD) and lower limit of quantification (LLOQ) were 2.5 and 8.3 fmol/ml, respectively. We investigated linearity of response, accuracy, precision, recovery, reproducibility and stability of SST during both short-term sample processing and long-term storage. This method allows reliable quantification of plasma peptides. The developed automated sample preparation solid phase extraction method can be easily and conveniently adopted for different volumes and amounts of sample in routine analysis using controlled vacuum. The highest advantage is enhanced reproducibility, which makes it suitable for the investigations of large sample cohorts in clinical studies.


[GRAPHICS]


英文关键词Automation controlled vacuum liquid handling robot nanoLC-MS somatostatin SPE LC
类型Article
语种英语
国家Hungary
收录类别SCI-E
WOS记录号WOS:000402977700003
WOS关键词SOLID-PHASE EXTRACTION ; MASS-SPECTROMETRY ; PEPTIDES ; RADIOIMMUNOASSAY ; QUANTIFICATION ; PLATFORM ; NEUROPEPTIDES ; HYPOTHALAMUS ; PROTEINS ; DISEASE
WOS类目Biochemical Research Methods ; Chemistry, Analytical
WOS研究方向Biochemistry & Molecular Biology ; Chemistry
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/200638
作者单位1.Univ Pecs, Inst Biochem & Med Chem, Dept Analyt Biochem, Szigeti Str 12, H-7624 Pecs, Hungary;
2.MTA Ctr Ecol, Balaton Limnol Inst, Dept Expt Zool, MTA OK BLI NAP B Adapt Neuroethol, Tihany, Hungary;
3.Univ Pecs, Janos Szentagothai Res Ctr, Pecs, Hungary;
4.Univ Pecs, Imaging Ctr Life & Mat Sci, Pecs, Hungary;
5.Univ Pecs, MTA PTE Human Reprod Sci Res Grp, Pecs, Hungary
推荐引用方式
GB/T 7714
Maasz, Gabor,Schmidt, Janos,Avar, Peter,et al. Automated SPE and nanoLC-MS analysis of somatostatin[J],2017,40(8):400-406.
APA Maasz, Gabor,Schmidt, Janos,Avar, Peter,&Mark, Laszlo.(2017).Automated SPE and nanoLC-MS analysis of somatostatin.JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES,40(8),400-406.
MLA Maasz, Gabor,et al."Automated SPE and nanoLC-MS analysis of somatostatin".JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES 40.8(2017):400-406.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Maasz, Gabor]的文章
[Schmidt, Janos]的文章
[Avar, Peter]的文章
百度学术
百度学术中相似的文章
[Maasz, Gabor]的文章
[Schmidt, Janos]的文章
[Avar, Peter]的文章
必应学术
必应学术中相似的文章
[Maasz, Gabor]的文章
[Schmidt, Janos]的文章
[Avar, Peter]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。