Arid
DOI10.1016/j.jchromb.2017.05.007
Simultaneous determination of bisphenol A and estrogens in hair samples by liquid chromatography-electrospray tandem mass spectrometry
Lee, Chaelin1,2; Kim, Chong Hyeak1; Kim, Sunghwan2; Cho, Sung-Hee1
通讯作者Cho, Sung-Hee
来源期刊JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
ISSN1570-0232
EISSN1873-376X
出版年2017
卷号1058页码:8-13
英文摘要

Bisphenol A (BPA), an endocrine disrupter, is widely used to make chemicals for polycarbonate, plastics, beverage containers, epoxy resins, and cash register receipts. BPA is one of the known xenoestrogens, which have weak estrogenic activity and cause obesity, diabetes, breast cancer, and reproductive disorders. Even though the concentration level of metabolomes in hair is usually lower than that in urine and blood, there are several reasons why we chose to use hair samples. First, the sampling procedure of hairs is simple. Second, it is also easy to preserve the sample for long term and track the drug-exposure record of a given sample. Third, deformation and contamination of samples rarely occur. In this study, an improved analytical method to determine the levels of BPA and estrogens in hair samples was developed by liquid chromatography-electrospray tandem mass spectrometry (LC-ESI/MS/MS). Hair samples were extracted by an Oasis HLB extraction cartridge after incubation with 1 N HCl and derivatized with dansyl chloride to increase sensitivity. BPA and estrogens (estrone, 17 beta-estradiol, and estriol) were separated using Shiseido CAPCELL PAK C-18 column (2.0 x 100 mm, 3 mu m) and a mobile phase consisting of 10 mM ammonium acetate in water and acetonitrile with a gradient program at a flow rate of 0.3 mL/min and were monitored with electrospray tandem mass spectrometry (ESI MS/MS). The linearity of this method was over 0.995. The limits of detection (LOD) at a signal-to-noise (S/N) ratio of 3 were 0.25-6.0 ng/g. The alteration of estrogens levels induced by BPA may play important role to understanding probable endocrine disruptive exposure, and the described methods could be used to evaluate and monitor exposure of endocrine disruptor.


英文关键词Bisphenol A Estrogens Hair Liquid chromatography Mass spectrometry
类型Article
语种英语
国家South Korea
收录类别SCI-E
WOS记录号WOS:000403626600002
WOS关键词HUMAN URINE ; ENVIRONMENTAL ESTROGENS ; ENDOCRINE ; EXPOSURE ; QUANTIFICATION ; VALIDATION ; PLASMA ; DERIVATIZATION ; ASSOCIATION ; DANSYLATION
WOS类目Biochemical Research Methods ; Chemistry, Analytical
WOS研究方向Biochemistry & Molecular Biology ; Chemistry
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/200260
作者单位1.KRICT, Ctr Chem Anal, Daejeon 305600, South Korea;
2.Kyungpook Natl Univ, Dept Chem, Daegu 41566, South Korea
推荐引用方式
GB/T 7714
Lee, Chaelin,Kim, Chong Hyeak,Kim, Sunghwan,et al. Simultaneous determination of bisphenol A and estrogens in hair samples by liquid chromatography-electrospray tandem mass spectrometry[J],2017,1058:8-13.
APA Lee, Chaelin,Kim, Chong Hyeak,Kim, Sunghwan,&Cho, Sung-Hee.(2017).Simultaneous determination of bisphenol A and estrogens in hair samples by liquid chromatography-electrospray tandem mass spectrometry.JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES,1058,8-13.
MLA Lee, Chaelin,et al."Simultaneous determination of bisphenol A and estrogens in hair samples by liquid chromatography-electrospray tandem mass spectrometry".JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES 1058(2017):8-13.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Lee, Chaelin]的文章
[Kim, Chong Hyeak]的文章
[Kim, Sunghwan]的文章
百度学术
百度学术中相似的文章
[Lee, Chaelin]的文章
[Kim, Chong Hyeak]的文章
[Kim, Sunghwan]的文章
必应学术
必应学术中相似的文章
[Lee, Chaelin]的文章
[Kim, Chong Hyeak]的文章
[Kim, Sunghwan]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。