Aqua and Terra MODIS RSB Calibration Comparison Using BRDF Modeled Reflectance
Chang, Tiejun1; Xiong, Xiaoxiong2; Angal, Amit1; Wu, Aisheng1; Geng, Xu1
通讯作者Chang, Tiejun
来源期刊IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING
ISSN0196-2892
EISSN1558-0644
出版年2017
卷号55期号:4页码:2288-2298
英文摘要

The intercomparison of Moderate Resolution Imaging Spectroradiometer (MODIS) reflective solar bands onboard Aqua and Terra is very important for the assessment of each instrument’s calibration. One of the limitations is the lack of simultaneous nadir overpasses. Their measurements over a selected Earth view target have significant differences in solar and view angles, which magnify the effects of atmospheric scattering and bidirectional reflectance distribution function (BRDF). In this paper, an intercomparison technique is formulated after correction for site’s BRDF and atmospheric effects. The reflectance measurements over Libya desert sites 1, 2, and 4 from both the Aqua and Terra MODIS are regressed to a BRDF model with an adjustable coefficient accounting for calibration difference. The ratio between Aqua and Terra reflectance measurements is derived for bands 1-9 and the results from different sites show good agreement. For year 2003, the ratios are in the range of 0.985-1.010 for bands 1-9. Band 3 shows the lowest ratio 0.985 and band 1 shows the highest ratio 1.010. For the year 2014, the ratio ranges from approximately 0.983 for bands 2 and 1.012 for band 8. The BRDF corrected reflectance for the two instruments is also derived for every year from 2003 to 2014 for stability assessment. Bands 1 and 2 show greater than 1% differences between the two instruments. Aqua bands 1 and 2 show downward trends while Terra bands 1 and 2 show upward trends. Bands 8 and 9 of both Aqua and Terra show large variations of reflectance measurement over time.


英文关键词Atmospheric correction bidirectional reflectance distribution function (BRDF) intercomparison Moderate Resolution Imaging Spectroradiometer (MODIS) Radiometric calibration
类型Article
语种英语
国家USA
收录类别SCI-E
WOS记录号WOS:000396394900035
WOS关键词RESOLUTION IMAGING SPECTRORADIOMETER ; RADIATIVE-TRANSFER CODE ; SOLAR BANDS ; CROSS-CALIBRATION ; ATMOSPHERIC CORRECTION ; VECTOR VERSION ; SATELLITE DATA ; PERFORMANCE ; RETRIEVAL ; SENSORS
WOS类目Geochemistry & Geophysics ; Engineering, Electrical & Electronic ; Remote Sensing ; Imaging Science & Photographic Technology
WOS研究方向Geochemistry & Geophysics ; Engineering ; Remote Sensing ; Imaging Science & Photographic Technology
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/199577
作者单位1.Sci Syst & Applicat Inc, Lanham, MD 20706 USA;
2.NASA, Goddard Space Flight Ctr, Sci & Explorat Directorate, Greenbelt, MD 20771 USA
推荐引用方式
GB/T 7714
Chang, Tiejun,Xiong, Xiaoxiong,Angal, Amit,et al. Aqua and Terra MODIS RSB Calibration Comparison Using BRDF Modeled Reflectance[J],2017,55(4):2288-2298.
APA Chang, Tiejun,Xiong, Xiaoxiong,Angal, Amit,Wu, Aisheng,&Geng, Xu.(2017).Aqua and Terra MODIS RSB Calibration Comparison Using BRDF Modeled Reflectance.IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING,55(4),2288-2298.
MLA Chang, Tiejun,et al."Aqua and Terra MODIS RSB Calibration Comparison Using BRDF Modeled Reflectance".IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING 55.4(2017):2288-2298.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Chang, Tiejun]的文章
[Xiong, Xiaoxiong]的文章
[Angal, Amit]的文章
百度学术
百度学术中相似的文章
[Chang, Tiejun]的文章
[Xiong, Xiaoxiong]的文章
[Angal, Amit]的文章
必应学术
必应学术中相似的文章
[Chang, Tiejun]的文章
[Xiong, Xiaoxiong]的文章
[Angal, Amit]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。