Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1016/j.chemosphere.2016.10.107 |
Liquid chromatography-tandem mass spectrometry determination of synthetic cathinones and phenethylamines in influent wastewater of eight European cities | |
Bade, Richard1; Bijlsma, Lubertus1; Sancho, Juan V.1; Baz-Lomba, Jose A.2,3; Castiglioni, Sara4; Castrignano, Erika5; Causanilles, Ana6; Gracia-Lor, Emma1,4; Kasprzyk-Hordern, Barbara5; Kinyua, Juliet8; McCall, Ann-Kathrin9; van Nuijs, Alexander L. N.8; Ort, Christoph9; Plosz, Benedek G.10; Ramin, Pedram10; Rousis, Nikolaos I.4; Ryu, Yeonsuk2,3; Thomas, Kevin V.2; de Voogt, Pim6,7; Zuccato, Ettore4; Hernandez, Felix1 | |
通讯作者 | Hernandez, Felix |
来源期刊 | CHEMOSPHERE
![]() |
ISSN | 0045-6535 |
EISSN | 1879-1298 |
出版年 | 2017 |
卷号 | 168页码:1032-1041 |
英文摘要 | The popularity of new psychoactive substances (NPS) has grown in recent years, with certain NPS commonly and preferentially consumed even following the introduction of preventative legislation. With the objective to improve the knowledge on the use of NPS, a rapid and very sensitive method was developed for the determination of ten priority NPS (N-ethylcathinone, methylenedioxypyrovalerone (MDPV), methylone, butylone, methedrone, mephedrone, naphyrone, 25-C-NBOMe, 25-I-NBOMe and 25-B-NBOMe) in influent wastewater. Sample clean-up and pre-concentration was made by off-line solid phase extraction (SPE) with Oasis MCX cartridges. Isotopically labelled internal standards were used to correct for matrix effects and potential SPE losses. Following chromatographic separation on a C-18 column within 6 min, the compounds were measured by tandem mass spectrometry in positive ionization mode. The method was optimised and validated for all compounds. Limits of quantification were evaluated by spiking influent wastewater samples at 1 or 5 ng/L. An investigation into the stability of these compounds in influent wastewater was also performed, showing that, following acidification at pH 2, all compounds were relatively stable for up to 7 days. The method was then applied to influent wastewater samples from eight European countries, in which mephedrone, methylone and MDPV were detected. This work reveals that although NPS use is not as extensive as for classic illicit drugs, the application of a highly sensitive analytical procedure makes their detection in wastewater possible. The developed analytical methodology forms the basis of a subsequent model-based back-calculation of abuse rate in urban areas (i.e. wastewater-based epidemiology). (C) 2016 Elsevier Ltd. All rights reserved. |
英文关键词 | New psychoactive substances Ultra high-performance liquid chromatography Triple quadrupole Wastewater Stability Matrix effects |
类型 | Article |
语种 | 英语 |
国家 | Spain ; Norway ; Italy ; England ; Netherlands ; Belgium ; Switzerland ; Denmark |
收录类别 | SCI-E |
WOS记录号 | WOS:000400879900019 |
WOS关键词 | PSYCHOACTIVE SUBSTANCES ; ILLICIT DRUGS ; SURFACE-WATER ; DESIGNER DRUG ; UHPLC-QTOF ; SAMPLES ; AMPHETAMINE ; METABOLITES ; URINE ; MS/MS |
WOS类目 | Environmental Sciences |
WOS研究方向 | Environmental Sciences & Ecology |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/198091 |
作者单位 | 1.Univ Jaume 1, Res Inst Pesticides & Water, Avda Sos Baynat S-N, E-12071 Castellon de La Plana, Spain; 2.Norwegian Inst Water Res NIVA, Gaustadalleen 21, N-0349 Oslo, Norway; 3.Univ Oslo, Fac Med, POB 1078, N-0316 Oslo, Norway; 4.IRCCS Ist Ric Farmacol Mario Negri, Dept Environm Hlth Sci, Via La Masa 19, I-20156 Milan, Italy; 5.Univ Bath, Dept Chem, Fac Sci, Bath BA2 7AY, Avon, England; 6.KWR Watercycle Res Inst, Chem Water Qual & Hlth, POB 1072, NL-3430 BB Nieuwegein, Netherlands; 7.Univ Amsterdam, Inst Biodivers & Ecosyst Dynam, POB 94248, NL-1090 GE Amsterdam, Netherlands; 8.Univ Antwerp, Toxicol Ctr, Dept Pharmaceut Sci, Campus Drie Eiken,Univ Pl 1, B-2610 Antwerp, Belgium; 9.Eawag, Swiss Fed Inst Aquat Sci & Technol, CH-8600 Dubendorf, Switzerland; 10.Tech Univ Denmark, Dept Environm Engn, Miljovej,Bldg 115, DK-2800 Lyngby, Denmark |
推荐引用方式 GB/T 7714 | Bade, Richard,Bijlsma, Lubertus,Sancho, Juan V.,et al. Liquid chromatography-tandem mass spectrometry determination of synthetic cathinones and phenethylamines in influent wastewater of eight European cities[J],2017,168:1032-1041. |
APA | Bade, Richard.,Bijlsma, Lubertus.,Sancho, Juan V..,Baz-Lomba, Jose A..,Castiglioni, Sara.,...&Hernandez, Felix.(2017).Liquid chromatography-tandem mass spectrometry determination of synthetic cathinones and phenethylamines in influent wastewater of eight European cities.CHEMOSPHERE,168,1032-1041. |
MLA | Bade, Richard,et al."Liquid chromatography-tandem mass spectrometry determination of synthetic cathinones and phenethylamines in influent wastewater of eight European cities".CHEMOSPHERE 168(2017):1032-1041. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。