Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1097/FTD.0000000000000345 |
Determination of Colistin and Colistimethate Levels in Human Plasma and Urine by High-Performance Liquid Chromatography-Tandem Mass Spectrometry | |
Bihan, Kevin1,2; Lu, Qin3; Enjalbert, Manon1,2; Apparuit, Maxime1,2; Langeron, Olivier3; Rouby, Jean-Jacques3; Funck-Brentano, Christian1,2,4,5; Zahr, Noel1,2 | |
通讯作者 | Zahr, Noel |
来源期刊 | THERAPEUTIC DRUG MONITORING
![]() |
ISSN | 0163-4356 |
EISSN | 1536-3694 |
出版年 | 2016 |
卷号 | 38期号:6页码:796-803 |
英文摘要 | Background: Colistin is a polypeptide antibiotic from the polymyxin E group used for the treatment of infections caused by multidrug-resistant gram-negative bacteria. The main constituents, accounting for approximately 85% of this mixture, are colistin A (polymyxin E1) and colistin B (polymyxin E2). The aim of this study was to develop and validate new and fast methods of quantification of colistin A and B and its precursors [colistin methanesulfonate sodium (CMS) A and B] by ultraperformance liquid chromatography-tandem mass spectrometry in plasma and urine with short pretreatment and run times. Methods: Chromatography was performed on an Acquity UPLC-MS/MS system (WATERS) with a WATERS Acquity UPLC C18 column (4.6 x 150 mm, 3.5 mm particle size). The pretreatment of samples consists of precipitation and extraction into microcolumns plate and HLB 96-well plate 30 mm-30 mg (OASIS) with a Positive Pressure-96 (WATERS). Results: Quantification was performed using a multiple reaction monitoring of the following transitions: m/z 390.9/385.1 for colistin A, m/z 386.2/101.0 for colistin B, and m/z 602.4/241.1 for polymyxin B1 sulfate. In plasma and urine, calibration curves were linear from 30 to 6000 ng/mL for colistin A and from 15 to 3000 ng/mL for colistin B. With an acceptable accuracy and precision, the lower limit of quantification were set at 24.0 ng/mL and 12.0 ng/mL for colistin A and B in plasma, and at 18.0 ng/mL and 9.0 ng/mL for colistin A and B in urine. Conclusions: These LC-MS/MS methods of quantification for colistin A and B and its precursors (CMS A and B) in plasma and urine are fast, simple, specific, sensitive, accurate, precise, and reliable. Furthermore, they are linear and repeatable. These procedures were successfully applied to a pharmacokinetic study of a critically ill patient suffering from ventilator-associated pneumonia, who was treated with nebulized CMS. |
英文关键词 | colistin mass spectrometry pharmacokinetics colistimethate sodium |
类型 | Article |
语种 | 英语 |
国家 | France |
收录类别 | SCI-E |
WOS记录号 | WOS:000388894900022 |
WOS关键词 | CHEMICAL-STRUCTURE ; PSEUDOMONAS-AERUGINOSA ; POLYMYXIN-E ; METHANESULFONATE ; STABILITY |
WOS类目 | Medical Laboratory Technology ; Pharmacology & Pharmacy ; Toxicology |
WOS研究方向 | Medical Laboratory Technology ; Pharmacology & Pharmacy ; Toxicology |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/196676 |
作者单位 | 1.Hop La Pitie Salpetriere, AP HP, Dept Pharmacol, 47 Blvd Hop, F-75013 Paris, France; 2.Hop La Pitie Salpetriere, AP HP, CIC 1421, Paris, France; 3.UPMC Univ, Multidisciplinary Intens Care Unit, Pitie Salpetriere Hosp, Assistance Publ Hop Paris,Dept Anesthesiol & Crit, Paris, France; 4.UPMC Univ Paris 06, Sorbonne Univ, Dept Pharmacol, Fac Med, Paris, France; 5.UPMC Univ Paris 06, Sorbonne Univ, UMR ICAN 1166, Fac Med, Paris, France |
推荐引用方式 GB/T 7714 | Bihan, Kevin,Lu, Qin,Enjalbert, Manon,et al. Determination of Colistin and Colistimethate Levels in Human Plasma and Urine by High-Performance Liquid Chromatography-Tandem Mass Spectrometry[J],2016,38(6):796-803. |
APA | Bihan, Kevin.,Lu, Qin.,Enjalbert, Manon.,Apparuit, Maxime.,Langeron, Olivier.,...&Zahr, Noel.(2016).Determination of Colistin and Colistimethate Levels in Human Plasma and Urine by High-Performance Liquid Chromatography-Tandem Mass Spectrometry.THERAPEUTIC DRUG MONITORING,38(6),796-803. |
MLA | Bihan, Kevin,et al."Determination of Colistin and Colistimethate Levels in Human Plasma and Urine by High-Performance Liquid Chromatography-Tandem Mass Spectrometry".THERAPEUTIC DRUG MONITORING 38.6(2016):796-803. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。