Arid
DOI10.1002/elps.201500440
Trace determination of tetracyclines in water samples by capillary zone electrophoresis combining off-line and on-line sample preconcentration
Moreno-Gonzalez, David; Lupion-Enriquez, Isabel; Garcia-Campana, Ana M.
通讯作者Garcia-Campana, Ana M.
来源期刊ELECTROPHORESIS
ISSN0173-0835
EISSN1522-2683
出版年2016
卷号37期号:9页码:1212-1219
英文摘要

In this work, a sensitive and reliable method using capillary zone electrophoresis with UV detection has been developed for trace determination of tetracycline antibiotics in river, spring, and ground waters. A solid-phase extraction method using Oasis HLB was applied for off-line preconcentration and cleanup of water samples, in combination with an online preconcentration methodology named large volume sample stacking with polarity switching. Different parameters were optimized in order to obtain an adequate separation combined with the highest sensitivity, using 75 mM sodium carbonate (pH 10) and 1 mM EDTA as separation buffer, applying a voltage of 25 kV at 25 degrees C. The samples were injected in water at 1 bar for 1 min, applying then-25 kV and starting the sample stacking. Sample matrix removal from the capillary was controlled bymonitoring the electric current (when the 95% of the separation current is reached the stacking process is completed). The applied voltage was then switched from negative to a positive value of 25 kV in order to separate the compounds. Under optimum conditions, sensitivity enhancement factors ranged from 303 to 428 for the studied compounds. The combination of both off-line and on-line preconcentration procedures provided a total sensitivity enhancement factor about 20 000, obtaining detection limits from 67 to 167 ng/L. The precision (intra-and interday), expressed as% RSD was below 12%. Recoveries obtained from river, spring, and ground waters ranged from 87 to 96%. Thus, this procedure is suitable for monitoring these compounds in water samples.


英文关键词Capillary zone electrophoresis Environmental waters Large volume sample stacking with polarity switching Solid phase extraction Tetracyclines
类型Article
语种英语
国家Spain
收录类别SCI-E
WOS记录号WOS:000375724700014
WOS关键词ANTIBIOTIC-RESIDUES ; ENVIRONMENTAL WATERS ; WASTE-WATER ; PHARMACEUTICALS ; EXTRACTION ; STACKING ; MILK ; CZE
WOS类目Biochemical Research Methods ; Chemistry, Analytical
WOS研究方向Biochemistry & Molecular Biology ; Chemistry
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/192533
作者单位Univ Granada, Fac Sci, Dept Analyt Chem, Av Fuentenueva S-N, E-18071 Granada, Spain
推荐引用方式
GB/T 7714
Moreno-Gonzalez, David,Lupion-Enriquez, Isabel,Garcia-Campana, Ana M.. Trace determination of tetracyclines in water samples by capillary zone electrophoresis combining off-line and on-line sample preconcentration[J],2016,37(9):1212-1219.
APA Moreno-Gonzalez, David,Lupion-Enriquez, Isabel,&Garcia-Campana, Ana M..(2016).Trace determination of tetracyclines in water samples by capillary zone electrophoresis combining off-line and on-line sample preconcentration.ELECTROPHORESIS,37(9),1212-1219.
MLA Moreno-Gonzalez, David,et al."Trace determination of tetracyclines in water samples by capillary zone electrophoresis combining off-line and on-line sample preconcentration".ELECTROPHORESIS 37.9(2016):1212-1219.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Moreno-Gonzalez, David]的文章
[Lupion-Enriquez, Isabel]的文章
[Garcia-Campana, Ana M.]的文章
百度学术
百度学术中相似的文章
[Moreno-Gonzalez, David]的文章
[Lupion-Enriquez, Isabel]的文章
[Garcia-Campana, Ana M.]的文章
必应学术
必应学术中相似的文章
[Moreno-Gonzalez, David]的文章
[Lupion-Enriquez, Isabel]的文章
[Garcia-Campana, Ana M.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。