Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1007/s00216-016-9887-z |
Determination of novel brominated flame retardants and polybrominated diphenyl ethers in serum using gas chromatography-mass spectrometry with two simplified sample preparation procedures | |
Gao, Le1,2; Li, Jian1,2; Wu, Yandan3; Yu, Miaohao3; Chen, Tian1,2; Shi, Zhixiong1,2; Zhou, Xianqing1,2; Sun, Zhiwei1,2 | |
通讯作者 | Shi, Zhixiong |
来源期刊 | ANALYTICAL AND BIOANALYTICAL CHEMISTRY
![]() |
ISSN | 1618-2642 |
EISSN | 1618-2650 |
出版年 | 2016 |
卷号 | 408期号:27页码:7835-7844 |
英文摘要 | Two simple and efficient pretreatment procedures have been developed for the simultaneous extraction and cleanup of six novel brominated flame retardants (NBFRs) and eight common polybrominated diphenyl ethers (PBDEs) in human serum. The first sample pretreatment procedure was a quick, easy, cheap, effective, rugged, and safe (QuEChERS)-based approach. An acetone/hexane mixture was employed to isolate the lipid and analytes from the serum with a combination of MgSO4 and NaCl, followed by a dispersive solid-phase extraction (d-SPE) step using C18 particles as a sorbent. The second sample pretreatment procedure was based on solid-phase extraction. The sample extraction and cleanup were conducted directly on an Oasis HLB SPE column using 5 % aqueous isopropanol, concentrated sulfuric acid, and 10 % aqueous methanol, followed by elution with dichloromethane. The NBFRs and PBDEs were then detected using gas chromatography-negative chemical ionization mass spectrometry (GC-NCI MS). The methods were assessed for repeatability, accuracy, selectivity, limits of detection (LODs), and linearity. The results of spike recovery experiments in fetal bovine serum showed that average recoveries ranged from 77.9 % to 128.8 % with relative standard deviations (RSDs) from 0.73 % to 12.37 % for most of the analytes. The LODs for the analytes in fetal bovine serum ranged from 0.3 to 50.8 pg/mL except for decabromodiphenyl ethane. The proposed method was successfully applied to the determination of the 14 brominated flame retardants in human serum. The two pretreatment procedures described here are simple, accurate, and precise, and are suitable for the routine analysis of human serum. |
英文关键词 | Serum Polybrominated diphenyl ethers Novel brominated flame retardants Gas chromatography-mass spectrometry QuEChERS |
类型 | Article |
语种 | 英语 |
国家 | Peoples R China |
收录类别 | SCI-E |
WOS记录号 | WOS:000386061300032 |
WOS关键词 | SOLID-PHASE EXTRACTION ; LIQUID-CHROMATOGRAPHY ; GENERAL-POPULATION ; HUMAN EXPOSURE ; ASSOCIATIONS ; QUECHERS ; CHINA ; RESIDUES ; PBDES ; WOMEN |
WOS类目 | Biochemical Research Methods ; Chemistry, Analytical |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/191245 |
作者单位 | 1.Capital Med Univ, Sch Publ Hlth, Beijing 100069, Peoples R China; 2.Capital Med Univ, Beijing Key Lab Environm Toxicol, Beijing 100069, Peoples R China; 3.Hosp Shunyi Dist, Beijing 101300, Peoples R China |
推荐引用方式 GB/T 7714 | Gao, Le,Li, Jian,Wu, Yandan,et al. Determination of novel brominated flame retardants and polybrominated diphenyl ethers in serum using gas chromatography-mass spectrometry with two simplified sample preparation procedures[J],2016,408(27):7835-7844. |
APA | Gao, Le.,Li, Jian.,Wu, Yandan.,Yu, Miaohao.,Chen, Tian.,...&Sun, Zhiwei.(2016).Determination of novel brominated flame retardants and polybrominated diphenyl ethers in serum using gas chromatography-mass spectrometry with two simplified sample preparation procedures.ANALYTICAL AND BIOANALYTICAL CHEMISTRY,408(27),7835-7844. |
MLA | Gao, Le,et al."Determination of novel brominated flame retardants and polybrominated diphenyl ethers in serum using gas chromatography-mass spectrometry with two simplified sample preparation procedures".ANALYTICAL AND BIOANALYTICAL CHEMISTRY 408.27(2016):7835-7844. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。