Direct determination of glyphosate, glufosinate, and AMPA in soybean and corn by liquid chromatography/tandem mass spectrometry | |
Chamkasem, Narong; Harmon, Tiffany | |
通讯作者 | Chamkasem, Narong |
来源期刊 | ANALYTICAL AND BIOANALYTICAL CHEMISTRY
![]() |
ISSN | 1618-2642 |
EISSN | 1618-2650 |
出版年 | 2016 |
卷号 | 408期号:18页码:4995-5004 |
英文摘要 | Glyphosate, glufosinate, and aminomethylphosphonic acid (AMPA) are amphoteric, low mass, high water soluble, and do not have chromophore. They are very difficult to be retained on a reversed phase HPLC and detected by UV or fluorescence detectors. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed to determine these analytes in soybean and corn using a reversed phase with weak anion-exchange and cation-exchange mixed-mode Acclaim (TM) Trinity (TM) Q1 column. The sample was shaken with water containing ethylenediaminetetraacetic acid disodium salt (Na(2)EDTA) and acetic acid for 10 min to precipitate protein and extract the analytes into the solution. The supernatant was passed thru an Oasis HLB SPE to retain suspended particulates and non-polar interferences. The sample was directly injected and analyzed in 6 min by LC-MS/MS with no sample concentration or derivatization steps. Three isotopically labeled internal standards corresponding to each analyte were used to counter matrix suppression effect. Linearity of the detector response with a minimum coefficient of determination (R (2)) of more than 0.995 was demonstrated in the range of 10 to 1000 ng/mL for each analyte. Accuracy (recovery %) and precision (relative standard deviation or RSD %) were evaluated at the fortification levels of 0.1, 0.5, and 2 mu g/g in seven replicates in both soybean and corn samples. |
英文关键词 | Glyphosate Soybean Corn LC-MS/MS Direct determination |
类型 | Article |
语种 | 英语 |
国家 | USA |
收录类别 | SCI-E |
WOS记录号 | WOS:000378999500018 |
WOS关键词 | SOLID-PHASE EXTRACTION ; AMINOMETHYLPHOSPHONIC ACID ; RESIDUE DETERMINATION ; WATER ; SOIL |
WOS类目 | Biochemical Research Methods ; Chemistry, Analytical |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/191243 |
作者单位 | US FDA, Southeast Reg Lab, 60 Eighth St NE, Atlanta, GA 30309 USA |
推荐引用方式 GB/T 7714 | Chamkasem, Narong,Harmon, Tiffany. Direct determination of glyphosate, glufosinate, and AMPA in soybean and corn by liquid chromatography/tandem mass spectrometry[J],2016,408(18):4995-5004. |
APA | Chamkasem, Narong,&Harmon, Tiffany.(2016).Direct determination of glyphosate, glufosinate, and AMPA in soybean and corn by liquid chromatography/tandem mass spectrometry.ANALYTICAL AND BIOANALYTICAL CHEMISTRY,408(18),4995-5004. |
MLA | Chamkasem, Narong,et al."Direct determination of glyphosate, glufosinate, and AMPA in soybean and corn by liquid chromatography/tandem mass spectrometry".ANALYTICAL AND BIOANALYTICAL CHEMISTRY 408.18(2016):4995-5004. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。