Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1515/pjvs-2015-0037 |
Screening method for the determination of tetracyclines and fluoroquinolones in animal drinking water by liquid chromatography with diode array detector | |
Patyra, E.; Kowalczyk, E.; Grelik, A.; Przenioslo-Siwczynska, M.; Kwiatek, K. | |
通讯作者 | Patyra, E. |
来源期刊 | POLISH JOURNAL OF VETERINARY SCIENCES
![]() |
ISSN | 1505-1773 |
EISSN | 2300-2557 |
出版年 | 2015 |
卷号 | 18期号:2页码:283-289 |
英文摘要 | A liquid chromatography diode array detector (HPLC-DAD) procedure has been developed for the determination of oxytetracycline (OTC), tetracycline (TC), chlorotetracycline (CTC), doxycycline (DC), enrofloxacin (ENR), ciprofloxacin (CIP), sarafloxacin (SAR) and flumequine (FLU) residues in animal drinking water. This method was applied to animal drinking water. Solid-phase extraction (SPE) clean-up on an Oasis HLB cartridge allowed an extract suitable for liquid chromatographic analysis to be obtained. Chromatographic separation was carried out on a C18 analytical column, using gradient elution with 0.1% trifluoroacetic acid acetonitrile methanol at 30 degrees C. The flow-rate was 0.7 mL/min and the eluate was analysed at 330 nm. The whole procedure was evaluated according to the requirements of the Commission Decision 2002/657/EC, determining specificity, decision limit (CC alpha), detection capacity (CC beta), limit of detection (LOD), limit of quantification (LOQ), precision and accuracy during validation of the method. The recoveries of TCs and FQs from spiked samples at the levels of 10, 100 and 1000 mu g/L were higher than 82%. The developed method based on HPLC-DAD has been applied for the determination of four tetracyclines and four fluoroquinolones in animal drinking water samples. |
英文关键词 | tetracyclines fluoroquinolones water solid-phase extraction HPLC-DAD |
类型 | Article |
语种 | 英语 |
国家 | Poland |
收录类别 | SCI-E |
WOS记录号 | WOS:000356567000007 |
WOS关键词 | TANDEM MASS-SPECTROMETRY ; SOLID-PHASE EXTRACTION ; FLUORESCENCE DETECTION ; MACROLIDE ANTIBIOTICS ; PLASMA SAMPLES ; ELECTROPHORESIS ; MICROEXTRACTION ; QUINOLONES |
WOS类目 | Veterinary Sciences |
WOS研究方向 | Veterinary Sciences |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/189899 |
作者单位 | Natl Inst Vet Res, Dept Hyg Anim Feedingstuffs, PL-24100 Pulawy, Poland |
推荐引用方式 GB/T 7714 | Patyra, E.,Kowalczyk, E.,Grelik, A.,et al. Screening method for the determination of tetracyclines and fluoroquinolones in animal drinking water by liquid chromatography with diode array detector[J],2015,18(2):283-289. |
APA | Patyra, E.,Kowalczyk, E.,Grelik, A.,Przenioslo-Siwczynska, M.,&Kwiatek, K..(2015).Screening method for the determination of tetracyclines and fluoroquinolones in animal drinking water by liquid chromatography with diode array detector.POLISH JOURNAL OF VETERINARY SCIENCES,18(2),283-289. |
MLA | Patyra, E.,et al."Screening method for the determination of tetracyclines and fluoroquinolones in animal drinking water by liquid chromatography with diode array detector".POLISH JOURNAL OF VETERINARY SCIENCES 18.2(2015):283-289. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。