Arid
DOI10.1515/pjvs-2015-0037
Screening method for the determination of tetracyclines and fluoroquinolones in animal drinking water by liquid chromatography with diode array detector
Patyra, E.; Kowalczyk, E.; Grelik, A.; Przenioslo-Siwczynska, M.; Kwiatek, K.
通讯作者Patyra, E.
来源期刊POLISH JOURNAL OF VETERINARY SCIENCES
ISSN1505-1773
EISSN2300-2557
出版年2015
卷号18期号:2页码:283-289
英文摘要

A liquid chromatography diode array detector (HPLC-DAD) procedure has been developed for the determination of oxytetracycline (OTC), tetracycline (TC), chlorotetracycline (CTC), doxycycline (DC), enrofloxacin (ENR), ciprofloxacin (CIP), sarafloxacin (SAR) and flumequine (FLU) residues in animal drinking water. This method was applied to animal drinking water. Solid-phase extraction (SPE) clean-up on an Oasis HLB cartridge allowed an extract suitable for liquid chromatographic analysis to be obtained. Chromatographic separation was carried out on a C18 analytical column, using gradient elution with 0.1% trifluoroacetic acid acetonitrile methanol at 30 degrees C. The flow-rate was 0.7 mL/min and the eluate was analysed at 330 nm. The whole procedure was evaluated according to the requirements of the Commission Decision 2002/657/EC, determining specificity, decision limit (CC alpha), detection capacity (CC beta), limit of detection (LOD), limit of quantification (LOQ), precision and accuracy during validation of the method. The recoveries of TCs and FQs from spiked samples at the levels of 10, 100 and 1000 mu g/L were higher than 82%. The developed method based on HPLC-DAD has been applied for the determination of four tetracyclines and four fluoroquinolones in animal drinking water samples.


英文关键词tetracyclines fluoroquinolones water solid-phase extraction HPLC-DAD
类型Article
语种英语
国家Poland
收录类别SCI-E
WOS记录号WOS:000356567000007
WOS关键词TANDEM MASS-SPECTROMETRY ; SOLID-PHASE EXTRACTION ; FLUORESCENCE DETECTION ; MACROLIDE ANTIBIOTICS ; PLASMA SAMPLES ; ELECTROPHORESIS ; MICROEXTRACTION ; QUINOLONES
WOS类目Veterinary Sciences
WOS研究方向Veterinary Sciences
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/189899
作者单位Natl Inst Vet Res, Dept Hyg Anim Feedingstuffs, PL-24100 Pulawy, Poland
推荐引用方式
GB/T 7714
Patyra, E.,Kowalczyk, E.,Grelik, A.,et al. Screening method for the determination of tetracyclines and fluoroquinolones in animal drinking water by liquid chromatography with diode array detector[J],2015,18(2):283-289.
APA Patyra, E.,Kowalczyk, E.,Grelik, A.,Przenioslo-Siwczynska, M.,&Kwiatek, K..(2015).Screening method for the determination of tetracyclines and fluoroquinolones in animal drinking water by liquid chromatography with diode array detector.POLISH JOURNAL OF VETERINARY SCIENCES,18(2),283-289.
MLA Patyra, E.,et al."Screening method for the determination of tetracyclines and fluoroquinolones in animal drinking water by liquid chromatography with diode array detector".POLISH JOURNAL OF VETERINARY SCIENCES 18.2(2015):283-289.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Patyra, E.]的文章
[Kowalczyk, E.]的文章
[Grelik, A.]的文章
百度学术
百度学术中相似的文章
[Patyra, E.]的文章
[Kowalczyk, E.]的文章
[Grelik, A.]的文章
必应学术
必应学术中相似的文章
[Patyra, E.]的文章
[Kowalczyk, E.]的文章
[Grelik, A.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。