Tracking radiometric responsivity of optical sensors without on-board calibration systems-case of the Chinese HJ-1A/1B CCD sensors | |
Li, Jian; Chen, Xiaoling; Tian, Liqiao; Feng, Lian | |
通讯作者 | Tian, Liqiao |
来源期刊 | OPTICS EXPRESS
![]() |
ISSN | 1094-4087 |
出版年 | 2015 |
卷号 | 23期号:2页码:1829-1847 |
英文摘要 | The radiometric stability of satellite sensors is crucial for generating highly consistent remote sensing measurements and products. We have presented a radiometric responsivity tracking method designed especially for optical sensors without on-board calibration systems. Using a temporally stable desert site with high reflectance, the sensor responsivity was simulated using the Second Simulation of the Satellite Signal in the Solar Spectrum (6S) radiative transfer model (RTM) with information from validated MODIS atmospheric data. Next, radiometric responsivity drifting was identified using a linear regression of the time series bidirectional reflectance distribution function (BRDF) normalized coefficients. The proposed method was applied to Chinese HJ-1A/1B charge-coupled device (CCD) sensors, which have been on-orbit operations for more than 5 years without continuous assessment of their radiometric performance. Results from the Dunhuang desert site between 2008 and 2013 indicated that the CCD sensors degraded at various rates, with the most significant degradation occurring in the blue bands, ranging from 2.8% to 4.2% yr(-1). The red bands were more stable, with a degradation rate of 0.7-3.1% yr(-1). A cross-sensor comparison revealed the least degradation for the HJ-1A CCD1 (blue: 2.8%; green: 2.8%; red: 0.7%; and NIR: 0.9% yr(-1)), whereas the degradation of HJ-1B CCD1 was most pronounced (blue: 3.5%; green: 4.1%; red: 2.3%; and NIR: 3.4% yr(-1)). The uncertainties of the method were evaluated theoretically based on the propagation of uncertainties from all possible sources of the RT simulations. In addition, a cross comparison with matchup ground-based absolute calibration results was conducted. The comparison demonstrated that the method was useful for continuously monitoring the radiometric performance of remote sensors, such as HJ1A/ 1B CCD and GaoFen (GF) series (China’s latest high-definition Earth observation satellite), and indicated the potential use of the method for high-precision absolute calibration. (C) 2015 Optical Society of America |
类型 | Article |
语种 | 英语 |
国家 | Peoples R China |
收录类别 | SCI-E |
WOS记录号 | WOS:000349166100118 |
WOS关键词 | NEAR-INFRARED CHANNELS ; RESOLUTION IMAGING SPECTRORADIOMETER ; VICARIOUS CALIBRATION ; CROSS-CALIBRATION ; AEROSOL PROPERTIES ; SATELLITE CCD ; MODIS ; VALIDATION ; RETRIEVALS ; BRDF |
WOS类目 | Optics |
WOS研究方向 | Optics |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/189423 |
作者单位 | Wuhan Univ, State Key Lab Informat Engn Surveying Mapping & R, Wuhan 430079, Peoples R China |
推荐引用方式 GB/T 7714 | Li, Jian,Chen, Xiaoling,Tian, Liqiao,et al. Tracking radiometric responsivity of optical sensors without on-board calibration systems-case of the Chinese HJ-1A/1B CCD sensors[J],2015,23(2):1829-1847. |
APA | Li, Jian,Chen, Xiaoling,Tian, Liqiao,&Feng, Lian.(2015).Tracking radiometric responsivity of optical sensors without on-board calibration systems-case of the Chinese HJ-1A/1B CCD sensors.OPTICS EXPRESS,23(2),1829-1847. |
MLA | Li, Jian,et al."Tracking radiometric responsivity of optical sensors without on-board calibration systems-case of the Chinese HJ-1A/1B CCD sensors".OPTICS EXPRESS 23.2(2015):1829-1847. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。