Arid
DOI10.1016/j.jflm.2015.03.006
Analysis of organophosphorus pesticides in whole blood by GC-MS-mu ECD with forensic purposes
Valente, Nuno I. P.1,2; Tarelho, Sonia1; Castro, Andre L.1; Silvestre, Armando2,6; Teixeira, Helena M.3,4,5
通讯作者Tarelho, Sonia
来源期刊JOURNAL OF FORENSIC AND LEGAL MEDICINE
ISSN1752-928X
EISSN1532-2009
出版年2015
卷号33页码:28-34
英文摘要

In the present work, two multi-residue methods for the determination of ten organophosphorus pesticides (OPs), namely chlorfenvinphos, chlorpyrifos, diazinon, dimethoate, fenthion, malathion, parathion, phosalone, pirimiphos-methyl and quinalphos, in post-mortem whole blood samples are presented.


The adopted procedure uses GC-MS for screening and quantitation, and GC-mu ECD (electron capture detector) for compound confirmation. Three different Solid Phase Extraction (SPE) procedures for OPs with Oasis (R) hydrophilic lipophilic balanced (HLB) and Sep-Pak (R) C18 cartridges were tested, and followed by GC-mu ECD and GC-MS analysis. The Sep-Pak (R) C18 cartridges extraction procedure was selected since it generated analytical signals 5 times higher than those obtained with the two different Oasis (R) HLB cartridges extraction procedures. The method has shown to be selective for the isolation of selected OPs as well as to the chosen internal standard (ethion) in postmortem blood samples. Calibration curves between 50 and 5000 ng/mL were prepared using weighted linear regression models (1/x(2)). It was not possible to establish a working range for fenthion by GC-mu ECD due to the lower sensitivity of the detector to this compound, whereas for pirimiphos-methyl it was set between 500 and 5000 ng/mL. The limit of quantitation was established at 50 ng/mL for all analytes, except for pirimiphos-methyl by GC-mu ECD analysis (500 ng/mL). The average extraction efficiency ranged from 72 to 102%.


The developed methods were considered robust and fit for the purpose, and had already been adopted in the laboratory routine analysis. (C) 2015 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.


英文关键词GC-MS-ECD Analytical method validation Organophosphorus pesticides Post-mortem blood samples SPE Sep-Pak C18 cartridges
类型Article
语种英语
国家Portugal
收录类别SCI-E
WOS记录号WOS:000355681900007
WOS关键词CAPILLARY GAS-CHROMATOGRAPHY ; SOLID-PHASE MICROEXTRACTION ; HUMAN-BODY FLUIDS ; TANDEM MASS-SPECTROMETRY ; HUMAN SERUM ; MULTIRESIDUE DETERMINATION ; POSTMORTEM TOXICOLOGY ; SAMPLES ; CHLORPYRIFOS ; EXTRACTION
WOS类目Medicine, Legal
WOS研究方向Legal Medicine
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/188624
作者单位1.Natl Inst Legal Med & Forens Sci, North Branch, Chem & Forens Sci Serv, P-4050067 Oporto, Portugal;
2.Univ Aveiro, Dept Chem, P-3810193 Aveiro, Portugal;
3.CICECO Ctr Res Ceram & Composite Mat, Complexo Lab Tecnol, P-3810193 Aveiro, Portugal;
4.Natl Inst Legal Med & Forens Sci, Res Format & Documentat Serv, P-3000213 Coimbra, Portugal;
5.Univ Coimbra, Fac Med, P-3004504 Coimbra, Portugal;
6.Univ Porto, Fac Med, P-4200319 Oporto, Portugal
推荐引用方式
GB/T 7714
Valente, Nuno I. P.,Tarelho, Sonia,Castro, Andre L.,et al. Analysis of organophosphorus pesticides in whole blood by GC-MS-mu ECD with forensic purposes[J],2015,33:28-34.
APA Valente, Nuno I. P.,Tarelho, Sonia,Castro, Andre L.,Silvestre, Armando,&Teixeira, Helena M..(2015).Analysis of organophosphorus pesticides in whole blood by GC-MS-mu ECD with forensic purposes.JOURNAL OF FORENSIC AND LEGAL MEDICINE,33,28-34.
MLA Valente, Nuno I. P.,et al."Analysis of organophosphorus pesticides in whole blood by GC-MS-mu ECD with forensic purposes".JOURNAL OF FORENSIC AND LEGAL MEDICINE 33(2015):28-34.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Valente, Nuno I. P.]的文章
[Tarelho, Sonia]的文章
[Castro, Andre L.]的文章
百度学术
百度学术中相似的文章
[Valente, Nuno I. P.]的文章
[Tarelho, Sonia]的文章
[Castro, Andre L.]的文章
必应学术
必应学术中相似的文章
[Valente, Nuno I. P.]的文章
[Tarelho, Sonia]的文章
[Castro, Andre L.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。