Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1016/j.jflm.2015.03.006 |
Analysis of organophosphorus pesticides in whole blood by GC-MS-mu ECD with forensic purposes | |
Valente, Nuno I. P.1,2; Tarelho, Sonia1; Castro, Andre L.1; Silvestre, Armando2,6; Teixeira, Helena M.3,4,5 | |
通讯作者 | Tarelho, Sonia |
来源期刊 | JOURNAL OF FORENSIC AND LEGAL MEDICINE
![]() |
ISSN | 1752-928X |
EISSN | 1532-2009 |
出版年 | 2015 |
卷号 | 33页码:28-34 |
英文摘要 | In the present work, two multi-residue methods for the determination of ten organophosphorus pesticides (OPs), namely chlorfenvinphos, chlorpyrifos, diazinon, dimethoate, fenthion, malathion, parathion, phosalone, pirimiphos-methyl and quinalphos, in post-mortem whole blood samples are presented. The adopted procedure uses GC-MS for screening and quantitation, and GC-mu ECD (electron capture detector) for compound confirmation. Three different Solid Phase Extraction (SPE) procedures for OPs with Oasis (R) hydrophilic lipophilic balanced (HLB) and Sep-Pak (R) C18 cartridges were tested, and followed by GC-mu ECD and GC-MS analysis. The Sep-Pak (R) C18 cartridges extraction procedure was selected since it generated analytical signals 5 times higher than those obtained with the two different Oasis (R) HLB cartridges extraction procedures. The method has shown to be selective for the isolation of selected OPs as well as to the chosen internal standard (ethion) in postmortem blood samples. Calibration curves between 50 and 5000 ng/mL were prepared using weighted linear regression models (1/x(2)). It was not possible to establish a working range for fenthion by GC-mu ECD due to the lower sensitivity of the detector to this compound, whereas for pirimiphos-methyl it was set between 500 and 5000 ng/mL. The limit of quantitation was established at 50 ng/mL for all analytes, except for pirimiphos-methyl by GC-mu ECD analysis (500 ng/mL). The average extraction efficiency ranged from 72 to 102%. The developed methods were considered robust and fit for the purpose, and had already been adopted in the laboratory routine analysis. (C) 2015 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved. |
英文关键词 | GC-MS-ECD Analytical method validation Organophosphorus pesticides Post-mortem blood samples SPE Sep-Pak C18 cartridges |
类型 | Article |
语种 | 英语 |
国家 | Portugal |
收录类别 | SCI-E |
WOS记录号 | WOS:000355681900007 |
WOS关键词 | CAPILLARY GAS-CHROMATOGRAPHY ; SOLID-PHASE MICROEXTRACTION ; HUMAN-BODY FLUIDS ; TANDEM MASS-SPECTROMETRY ; HUMAN SERUM ; MULTIRESIDUE DETERMINATION ; POSTMORTEM TOXICOLOGY ; SAMPLES ; CHLORPYRIFOS ; EXTRACTION |
WOS类目 | Medicine, Legal |
WOS研究方向 | Legal Medicine |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/188624 |
作者单位 | 1.Natl Inst Legal Med & Forens Sci, North Branch, Chem & Forens Sci Serv, P-4050067 Oporto, Portugal; 2.Univ Aveiro, Dept Chem, P-3810193 Aveiro, Portugal; 3.CICECO Ctr Res Ceram & Composite Mat, Complexo Lab Tecnol, P-3810193 Aveiro, Portugal; 4.Natl Inst Legal Med & Forens Sci, Res Format & Documentat Serv, P-3000213 Coimbra, Portugal; 5.Univ Coimbra, Fac Med, P-3004504 Coimbra, Portugal; 6.Univ Porto, Fac Med, P-4200319 Oporto, Portugal |
推荐引用方式 GB/T 7714 | Valente, Nuno I. P.,Tarelho, Sonia,Castro, Andre L.,et al. Analysis of organophosphorus pesticides in whole blood by GC-MS-mu ECD with forensic purposes[J],2015,33:28-34. |
APA | Valente, Nuno I. P.,Tarelho, Sonia,Castro, Andre L.,Silvestre, Armando,&Teixeira, Helena M..(2015).Analysis of organophosphorus pesticides in whole blood by GC-MS-mu ECD with forensic purposes.JOURNAL OF FORENSIC AND LEGAL MEDICINE,33,28-34. |
MLA | Valente, Nuno I. P.,et al."Analysis of organophosphorus pesticides in whole blood by GC-MS-mu ECD with forensic purposes".JOURNAL OF FORENSIC AND LEGAL MEDICINE 33(2015):28-34. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。