Screening approach by ultra-high performance liquid chromatography-tandem mass spectrometry for the blood quantification of thirty-four toxic principles of plant origin. Application to forensic toxicology
Carlier, Jeremy1,2; Guitton, Jerome3,4; Romeuf, Ludovic1; Bevalot, Fabien5; Boyer, Baptiste6; Fanton, Laurent7; Gaillard, Yvan1
通讯作者Carlier, Jeremy
来源期刊JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
ISSN1570-0232
EISSN1873-376X
出版年2015
卷号975页码:65-76
英文摘要

Plant poisonings have left their mark on history and still cause many deaths, whether intentional or accidental. The means to show toxicological evidence of such poisonings should be implemented with great care. This article presents a technique for measuring thirty-nine toxic principles of plant origin in the blood, covering a large amount of toxins from local or exotic plants: alpha-lobeline, alpha-solanine, aconitine, ajmaline, atropine, brucine, cephalomannine, colchicine, convallatoxin, cymarine, cytisine, digitoxin, digoxin, emetine, gelsemine, ibogaine, jervine, kavain, lanatoside C, lupanine, mitragynine, neriifolin, oleandrin, ouabain, paclitaxel, physostigmine, pilocarpine, podophyllotoxin, proscillaridin A, reserpine, retrorsine, ricinine, scopolamine, senecionine, sparteine, strophanthidin, strychnine, veratridine and yohimbine. Analysis was carried out using an original ultra-high performance liquid chromatography separation coupled with tandem mass spectrometry detection. Extraction was a standard solid phase extraction performed on Oasis (R) HLB cartridge. Thirty-four of the thirty-nine compounds were put through a validation procedure. The assay was linear in the calibration curve range from 0.5 or 5 mu g/L to 1000 mu g/L according to the compounds. The method is sensitive (LOD from 0.1 to 1.6 mu g/L). The within-day precision of the assay was less than 22.5% at the LLOQ, and the between-day precision was less than 21.5% for 10 mu g/L for all the compounds included. The assay accuracy was in the range of 87.4 to 119.8% for the LLOQ, The extraction recovery and matrix effect ranged from 30 to 106% and from 30 to 14%, respectively. It has proven useful and effective in several difficult forensic cases. (C) 2014 Elsevier B.V. All rights reserved.


英文关键词Toxic plants Multiresidue screening Forensic toxicology Ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS)
类型Article
语种英语
国家France
收录类别SCI-E
WOS记录号WOS:000347591300010
WOS关键词POISON CONTROL CENTERS ; LC-ESI-MS/MS ; BODY-FLUIDS ; ALKALOIDS ; DIGOXIN ; IBOGAINE ; SAMPLES ; IDENTIFICATION ; URINE ; DRUGS
WOS类目Biochemical Research Methods ; Chemistry, Analytical
WOS研究方向Biochemistry & Molecular Biology ; Chemistry
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/188474
作者单位1.Lab LAT LUMTOX, F-07800 La Voulte Sur Rhone, France;
2.Univ Lyon 1, Hop Louis Pradel, Ecole Doctorale Interdisciplinaire Sci Sante, F-69677 Bron, France;
3.Fac Pharm Lyon, Toxicol Lab, F-69373 Lyon, France;
4.Ctr Hosp Lyon Sud, Hosp Civils Lyon, Lab Pharmacol Toxicol, F-69495 Pierre Benite, France;
5.Lab LAT LUMTOX, F-69003 Lyon, France;
6.Ctr Hosp Univ Clermont Ferrand, Inst Med Legal, F-63003 Clermont Ferrand, France;
7.Fac Med, Inst Med Legal, F-69008 Lyon, France
推荐引用方式
GB/T 7714
Carlier, Jeremy,Guitton, Jerome,Romeuf, Ludovic,et al. Screening approach by ultra-high performance liquid chromatography-tandem mass spectrometry for the blood quantification of thirty-four toxic principles of plant origin. Application to forensic toxicology[J],2015,975:65-76.
APA Carlier, Jeremy.,Guitton, Jerome.,Romeuf, Ludovic.,Bevalot, Fabien.,Boyer, Baptiste.,...&Gaillard, Yvan.(2015).Screening approach by ultra-high performance liquid chromatography-tandem mass spectrometry for the blood quantification of thirty-four toxic principles of plant origin. Application to forensic toxicology.JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES,975,65-76.
MLA Carlier, Jeremy,et al."Screening approach by ultra-high performance liquid chromatography-tandem mass spectrometry for the blood quantification of thirty-four toxic principles of plant origin. Application to forensic toxicology".JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES 975(2015):65-76.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Carlier, Jeremy]的文章
[Guitton, Jerome]的文章
[Romeuf, Ludovic]的文章
百度学术
百度学术中相似的文章
[Carlier, Jeremy]的文章
[Guitton, Jerome]的文章
[Romeuf, Ludovic]的文章
必应学术
必应学术中相似的文章
[Carlier, Jeremy]的文章
[Guitton, Jerome]的文章
[Romeuf, Ludovic]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。