Arid
DOI10.1002/elps.201400230
Use of high-conductivity sample solution with sweeping-micellar electrokinetic capillary chromatography for trace-level quantification of paliperidone in human plasma
Liu, Hsiang-Yin1; Hwang, Tzung-Jeng2,3,4; Tsai, I-Lin1; Kuo, Ching-Hua1,5
通讯作者Kuo, Ching-Hua
来源期刊ELECTROPHORESIS
ISSN0173-0835
EISSN1522-2683
出版年2015
卷号36期号:4页码:534-542
英文摘要

Paliperidone is a new antipsychotic drug with a relatively low therapeutic concentration of 20-60 ng/mL. We established an accurate and sensitive CE method for the determination of paliperidone concentrations in human plasma in this study. To minimize matrix effect caused by quantification errors, paliperidone was extracted from human plasma using Oasis HLB SPE cartridges with three-step washing procedure. To achieve sensitive quantification of paliperidone in human plasma, a high-conductivity sample solution with sweeping-MEKC method was applied for analysis. The separation is performed in a BGE composed of 75 mM phosphoric acid, 100 mM SDS, 12% acetonitrile, and 15% tetrahydrofuran. Sample solution consisted of 10% methanol in 250 mM phosphoric acid and the conductivity ratio between sample matrix and BGE was 2.0 (gamma, sample/BGE). The results showed it able to detect paliperidone in plasma samples at concentration as low as 10 ng/mL (S/N = 3) with a linear range between 20 and 200 ng/mL. Compared to the conventional MEKC method, the sensitivity enhancement factor of the developed sweeping-MEKC method was 100. Intra-and interday precision of peak area ratios were less than 6.03%; the method accuracy was between 93.4 and 97.9%. This method was successfully applied to the analysis of plasma samples of patients undergoing paliperidone treatment.


英文关键词Capillary electrophoresis Paliperidone Sweeping-MEKC Therapeutic drug monitoring
类型Article
语种英语
国家Taiwan
收录类别SCI-E
WOS记录号WOS:000349969700007
WOS关键词PERFORMANCE LIQUID-CHROMATOGRAPHY ; ACTIVE METABOLITE 9-HYDROXYRISPERIDONE ; TANDEM MASS-SPECTROMETRY ; ELECTROCHEMICAL DETECTION ; ULTRAVIOLET DETECTION ; NEUTRAL ANALYTES ; MAIN METABOLITE ; RISPERIDONE ; ELECTROPHORESIS ; STACKING
WOS类目Biochemical Research Methods ; Chemistry, Analytical
WOS研究方向Biochemistry & Molecular Biology ; Chemistry
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/186892
作者单位1.Natl Taiwan Univ, Sch Pharm, Taipei 100, Taiwan;
2.Natl Taiwan Univ Hosp, Dept Psychiat, Taipei, Taiwan;
3.Coll Med, Taipei, Taiwan;
4.Natl Taiwan Univ, Neurobiol & Cognit Sci Ctr, Taipei 100, Taiwan;
5.Natl Taiwan Univ Hosp, Dept Pharm, Taipei, Taiwan
推荐引用方式
GB/T 7714
Liu, Hsiang-Yin,Hwang, Tzung-Jeng,Tsai, I-Lin,et al. Use of high-conductivity sample solution with sweeping-micellar electrokinetic capillary chromatography for trace-level quantification of paliperidone in human plasma[J],2015,36(4):534-542.
APA Liu, Hsiang-Yin,Hwang, Tzung-Jeng,Tsai, I-Lin,&Kuo, Ching-Hua.(2015).Use of high-conductivity sample solution with sweeping-micellar electrokinetic capillary chromatography for trace-level quantification of paliperidone in human plasma.ELECTROPHORESIS,36(4),534-542.
MLA Liu, Hsiang-Yin,et al."Use of high-conductivity sample solution with sweeping-micellar electrokinetic capillary chromatography for trace-level quantification of paliperidone in human plasma".ELECTROPHORESIS 36.4(2015):534-542.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Liu, Hsiang-Yin]的文章
[Hwang, Tzung-Jeng]的文章
[Tsai, I-Lin]的文章
百度学术
百度学术中相似的文章
[Liu, Hsiang-Yin]的文章
[Hwang, Tzung-Jeng]的文章
[Tsai, I-Lin]的文章
必应学术
必应学术中相似的文章
[Liu, Hsiang-Yin]的文章
[Hwang, Tzung-Jeng]的文章
[Tsai, I-Lin]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。