Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1002/elps.201400230 |
Use of high-conductivity sample solution with sweeping-micellar electrokinetic capillary chromatography for trace-level quantification of paliperidone in human plasma | |
Liu, Hsiang-Yin1; Hwang, Tzung-Jeng2,3,4; Tsai, I-Lin1; Kuo, Ching-Hua1,5 | |
通讯作者 | Kuo, Ching-Hua |
来源期刊 | ELECTROPHORESIS
![]() |
ISSN | 0173-0835 |
EISSN | 1522-2683 |
出版年 | 2015 |
卷号 | 36期号:4页码:534-542 |
英文摘要 | Paliperidone is a new antipsychotic drug with a relatively low therapeutic concentration of 20-60 ng/mL. We established an accurate and sensitive CE method for the determination of paliperidone concentrations in human plasma in this study. To minimize matrix effect caused by quantification errors, paliperidone was extracted from human plasma using Oasis HLB SPE cartridges with three-step washing procedure. To achieve sensitive quantification of paliperidone in human plasma, a high-conductivity sample solution with sweeping-MEKC method was applied for analysis. The separation is performed in a BGE composed of 75 mM phosphoric acid, 100 mM SDS, 12% acetonitrile, and 15% tetrahydrofuran. Sample solution consisted of 10% methanol in 250 mM phosphoric acid and the conductivity ratio between sample matrix and BGE was 2.0 (gamma, sample/BGE). The results showed it able to detect paliperidone in plasma samples at concentration as low as 10 ng/mL (S/N = 3) with a linear range between 20 and 200 ng/mL. Compared to the conventional MEKC method, the sensitivity enhancement factor of the developed sweeping-MEKC method was 100. Intra-and interday precision of peak area ratios were less than 6.03%; the method accuracy was between 93.4 and 97.9%. This method was successfully applied to the analysis of plasma samples of patients undergoing paliperidone treatment. |
英文关键词 | Capillary electrophoresis Paliperidone Sweeping-MEKC Therapeutic drug monitoring |
类型 | Article |
语种 | 英语 |
国家 | Taiwan |
收录类别 | SCI-E |
WOS记录号 | WOS:000349969700007 |
WOS关键词 | PERFORMANCE LIQUID-CHROMATOGRAPHY ; ACTIVE METABOLITE 9-HYDROXYRISPERIDONE ; TANDEM MASS-SPECTROMETRY ; ELECTROCHEMICAL DETECTION ; ULTRAVIOLET DETECTION ; NEUTRAL ANALYTES ; MAIN METABOLITE ; RISPERIDONE ; ELECTROPHORESIS ; STACKING |
WOS类目 | Biochemical Research Methods ; Chemistry, Analytical |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/186892 |
作者单位 | 1.Natl Taiwan Univ, Sch Pharm, Taipei 100, Taiwan; 2.Natl Taiwan Univ Hosp, Dept Psychiat, Taipei, Taiwan; 3.Coll Med, Taipei, Taiwan; 4.Natl Taiwan Univ, Neurobiol & Cognit Sci Ctr, Taipei 100, Taiwan; 5.Natl Taiwan Univ Hosp, Dept Pharm, Taipei, Taiwan |
推荐引用方式 GB/T 7714 | Liu, Hsiang-Yin,Hwang, Tzung-Jeng,Tsai, I-Lin,et al. Use of high-conductivity sample solution with sweeping-micellar electrokinetic capillary chromatography for trace-level quantification of paliperidone in human plasma[J],2015,36(4):534-542. |
APA | Liu, Hsiang-Yin,Hwang, Tzung-Jeng,Tsai, I-Lin,&Kuo, Ching-Hua.(2015).Use of high-conductivity sample solution with sweeping-micellar electrokinetic capillary chromatography for trace-level quantification of paliperidone in human plasma.ELECTROPHORESIS,36(4),534-542. |
MLA | Liu, Hsiang-Yin,et al."Use of high-conductivity sample solution with sweeping-micellar electrokinetic capillary chromatography for trace-level quantification of paliperidone in human plasma".ELECTROPHORESIS 36.4(2015):534-542. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。