Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1007/s00216-014-8377-4 |
Comparison of sample preparation methods for the quantitative analysis of eicosanoids and other oxylipins in plasma by means of LC-MS/MS | |
Ostermann, Annika I.1; Willenberg, Ina1; Schebb, Nils Helge1,2 | |
通讯作者 | Schebb, Nils Helge |
来源期刊 | ANALYTICAL AND BIOANALYTICAL CHEMISTRY
![]() |
ISSN | 1618-2642 |
EISSN | 1618-2650 |
出版年 | 2015 |
卷号 | 407期号:5页码:1403-1414 |
英文摘要 | Oxylipins are potent lipid mediators. For the evaluation of their biological roles, several LC-MS based methods have been developed. While these methods are similar, the described sample preparation procedures for the extraction of oxylipins differ considerably. In order to deduce the most appropriate method for the analysis of non-esterified oxylipins in human plasma, we evaluated the performance of seven established sample preparation procedures. Six commonly used solid phase extraction (SPE) and one liquid-liquid extraction (LLE) protocol were compared based on the recovery of 13 added internal standards, extraction efficacy of oxylipins from plasma and reduction of ion-suppressing matrix. Dramatic differences in the performance in all three parameters were found. LLE with ethyl acetate was overall not a sufficient sample preparation strategy. The protocols using Oasis-and StrataX-material insufficiently removed interfering matrix compounds. Extraction efficacy of oxylipins on anion-exchanging BondElut cartridges was low, while removal of matrix was nearly perfect. None of the protocols led to a high extraction efficacy of analytes while removing all interfering matrix components. However, SPE on a C18-material with removal of matrix by water and n-hexane prior elution with methyl formate showed the best performance for the analysis of a broad spectrum of oxylipins in plasma. |
英文关键词 | Eicosanoids Lipidomics Liquid-liquid extraction Solid phase extraction Oxylipins LC-MS |
类型 | Article |
语种 | 英语 |
国家 | Germany |
收录类别 | SCI-E |
WOS记录号 | WOS:000349336400013 |
WOS关键词 | LIPIDOMIC ANALYSIS ; ACID ; RESOLVINS ; MEDIATORS ; MODULATE |
WOS类目 | Biochemical Research Methods ; Chemistry, Analytical |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/185719 |
作者单位 | 1.Univ Vet Med Hannover, Inst Food Toxicol & Analyt Chem, D-30173 Hannover, Germany; 2.Univ Wuppertal, Inst Food Chem, D-42119 Wuppertal, Germany |
推荐引用方式 GB/T 7714 | Ostermann, Annika I.,Willenberg, Ina,Schebb, Nils Helge. Comparison of sample preparation methods for the quantitative analysis of eicosanoids and other oxylipins in plasma by means of LC-MS/MS[J],2015,407(5):1403-1414. |
APA | Ostermann, Annika I.,Willenberg, Ina,&Schebb, Nils Helge.(2015).Comparison of sample preparation methods for the quantitative analysis of eicosanoids and other oxylipins in plasma by means of LC-MS/MS.ANALYTICAL AND BIOANALYTICAL CHEMISTRY,407(5),1403-1414. |
MLA | Ostermann, Annika I.,et al."Comparison of sample preparation methods for the quantitative analysis of eicosanoids and other oxylipins in plasma by means of LC-MS/MS".ANALYTICAL AND BIOANALYTICAL CHEMISTRY 407.5(2015):1403-1414. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。