Comparative method validation for closantel determination in cattle and sheep milk according to European Union Volume 8 and Veterinary International Conference on Harmonization guidelines | |
Devreese, Mathias; Maes, An; De Baere, Siegrid; De Backer, Patrick; Croubels, Siska | |
通讯作者 | Devreese, Mathias |
来源期刊 | JOURNAL OF CHROMATOGRAPHY A
![]() |
ISSN | 0021-9673 |
EISSN | 1873-3778 |
出版年 | 2014 |
卷号 | 1353页码:106-113 |
英文摘要 | A specific and sensitive LC-MS/MS method was developed for quantitative determination of closantel in bovine and ovine colostrum and tank milk. Sample preparation consisted of extracting milk samples with acetonitrile/acetone (80/20, v/v) followed by SPE clean-up with Oasis (R) mixed anion exchange columns. After elution with 5% formic acid in acetonitrile and evaporation to dryness, the residue was reconstituted in acetonitrile and water. HPLC separation was achieved on a Zorbax (R) Eclipse Plus C18 column and a gradient elution program with 1 mM ammonium acetate in water and acetonitrile. For closantel determination in bovine milk, the method was validated according to EU Volume 8 guidelines whereas for ovine milk both EU Volume 8 and VICH GL49 criteria were applied. The linear range of the method is between 10 and 2000 mu g/kg, the limit of quantification 10 mu g/kg and limit of detection is 0.63 and 0.32 mu g/kg for sheep colostrum and tank milk and 1.27 and 1.24 mu g/kg for cattle colostrum and tank milk, respectively. Both guidelines cover a similar set of parameters (linearity, accuracy, precision, limit of detection and limit of quantification), although the acceptance criteria might differ (accuracy and precision) or no specific acceptability ranges are specified in neither guidelines (LOD and LOQ). For some parameters, only one of the guidelines indicates acceptance criteria: EU Volume 8 for applicability, practicability and susceptibility and VICH GL 49 for linearity, specificity and analyte stability. (C) 2014 Elsevier B.V. All rights reserved. |
英文关键词 | Closantel Milk MRL Method validation VICH GL 49 EU Volume 8 |
类型 | Article |
语种 | 英语 |
国家 | Belgium |
收录类别 | SCI-E |
WOS记录号 | WOS:000339036400013 |
WOS关键词 | TANDEM MASS-SPECTROMETRY ; PERFORMANCE LIQUID-CHROMATOGRAPHY ; SOLID-PHASE EXTRACTION ; FLUORESCENCE DETECTION ; ANIMAL-TISSUES ; RESIDUES ; HPLC ; BIOANALYSIS ; RAFOXANIDE ; STANDARDS |
WOS类目 | Biochemical Research Methods ; Chemistry, Analytical |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/183162 |
作者单位 | Univ Ghent, Fac Vet Med, Dept Pharmacol Toxicol & Biochem, B-9820 Merelbeke, Belgium |
推荐引用方式 GB/T 7714 | Devreese, Mathias,Maes, An,De Baere, Siegrid,et al. Comparative method validation for closantel determination in cattle and sheep milk according to European Union Volume 8 and Veterinary International Conference on Harmonization guidelines[J],2014,1353:106-113. |
APA | Devreese, Mathias,Maes, An,De Baere, Siegrid,De Backer, Patrick,&Croubels, Siska.(2014).Comparative method validation for closantel determination in cattle and sheep milk according to European Union Volume 8 and Veterinary International Conference on Harmonization guidelines.JOURNAL OF CHROMATOGRAPHY A,1353,106-113. |
MLA | Devreese, Mathias,et al."Comparative method validation for closantel determination in cattle and sheep milk according to European Union Volume 8 and Veterinary International Conference on Harmonization guidelines".JOURNAL OF CHROMATOGRAPHY A 1353(2014):106-113. |