Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1016/j.enbuild.2014.03.031 |
Strategies for reducing heating and cooling loads of uninsulated rammed earth wall houses | |
Dong, Xiang1; Soebarto, Veronica2; Griffith, Michael1 | |
通讯作者 | Dong, Xiang |
来源期刊 | ENERGY AND BUILDINGS
![]() |
ISSN | 0378-7788 |
EISSN | 1872-6178 |
出版年 | 2014 |
卷号 | 77页码:323-331 |
英文摘要 | The research reported in this paper investigated the potential reduction of heating and cooling loads in a hypothetical uninsulated rammed earth wall house. The analysis was performed in three different climate zones in Australia, namely: climate zone 3, 5 and 7, representing hot arid, warm temperate and cool temperate climate, respectively. The investigation involved simulating the energy load for a rammed earth house with different building parameters using the home energy rating software AccuRate developed by the Australian Commonwealth Scientific and Industrial Research Organisation (CSIRO). In Australia, new building designs must comply with the energy efficient provision of the Building Code of Australia in the National Construction Code (NCC), and one method of compliance is through an assessment of the predicted energy loads. The simulation results show that it is possible for an uninsulated rammed earth wall house in Australian climate zones 3 and 5, to fulfil the minimum requirement of the NCC as long as the building is designed carefully by optimising a number of passive solar strategies. In climate zone 7, however, uninsulated rammed earth houses cannot meet the NCC requirement even after applying passive solar design strategies. (C) 2014 Elsevier B.V. All rights reserved. |
英文关键词 | Rammed earth Thermal performance Simulation Passive solar strategy Energy load Star rating |
类型 | Article |
语种 | 英语 |
国家 | Australia |
收录类别 | SCI-E |
WOS记录号 | WOS:000339133100032 |
WOS关键词 | CLASSIFICATION ; BUILDINGS ; ENERGY |
WOS类目 | Construction & Building Technology ; Energy & Fuels ; Engineering, Civil |
WOS研究方向 | Construction & Building Technology ; Energy & Fuels ; Engineering |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/181786 |
作者单位 | 1.Univ Adelaide, Sch Civil Environm & Min Engn, Adelaide, SA 5005, Australia; 2.Univ Adelaide, Sch Architecture & Built Environm, Adelaide, SA 5005, Australia |
推荐引用方式 GB/T 7714 | Dong, Xiang,Soebarto, Veronica,Griffith, Michael. Strategies for reducing heating and cooling loads of uninsulated rammed earth wall houses[J],2014,77:323-331. |
APA | Dong, Xiang,Soebarto, Veronica,&Griffith, Michael.(2014).Strategies for reducing heating and cooling loads of uninsulated rammed earth wall houses.ENERGY AND BUILDINGS,77,323-331. |
MLA | Dong, Xiang,et al."Strategies for reducing heating and cooling loads of uninsulated rammed earth wall houses".ENERGY AND BUILDINGS 77(2014):323-331. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。