Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1177/0004563214524558 |
A widely applicable plasma renin activity assay by LC-MS/MS with offline solid phase extraction | |
Owen, Laura J.1,2; Adaway, Joanne1,2; Morris, Karen1; Lockhart, Stephen1; Keevil, Brian G.1,2 | |
通讯作者 | Owen, Laura J. |
来源期刊 | ANNALS OF CLINICAL BIOCHEMISTRY
![]() |
ISSN | 0004-5632 |
EISSN | 1758-1001 |
出版年 | 2014 |
卷号 | 51期号:3页码:409-411 |
英文摘要 | Background The measurement of plasma renin activity using LC-MS/MS is an attractive alternative to radioimmunoassay techniques. A published method for renin activity by LC-MS/MS uses equipment that is not available in all LC-MS/MS laboratories. Here, we present an offline modification to allow users of LC-MS/MS to perform this analysis without specialist equipment. Methods Samples were prepared in duplicate and incubated for 6.5 h and 24 h. Solid phase extraction was performed offline using Waters Oasis MAX ion-exchange 96-well plate. A method comparison was performed between this assay and a previously published assay using on-line solid phase extraction. Results The offline method for plasma rennin activity gave similar results to the on-line method across the concentration range. Analytical performance was also found to be comparable and the use of a 24 h incubation for low samples was also deemed unnecessary. Discussion The method described is an acceptable alternative to a previously published assay which does not require the use of highly specialist equipment and will be applicable to the majority of LC-MS/MS users. |
英文关键词 | LC-MS/MS solid phase extraction Renin activity |
类型 | Article |
语种 | 英语 |
国家 | England |
收录类别 | SCI-E |
WOS记录号 | WOS:000334175600013 |
WOS类目 | Medical Laboratory Technology |
WOS研究方向 | Medical Laboratory Technology |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/180664 |
作者单位 | 1.Univ S Manchester Hosp, Dept Biochem, Manchester M23 9LT, Lancs, England; 2.Univ Manchester, Manchester Acad Hlth Sci Ctr, Manchester, Lancs, England |
推荐引用方式 GB/T 7714 | Owen, Laura J.,Adaway, Joanne,Morris, Karen,et al. A widely applicable plasma renin activity assay by LC-MS/MS with offline solid phase extraction[J],2014,51(3):409-411. |
APA | Owen, Laura J.,Adaway, Joanne,Morris, Karen,Lockhart, Stephen,&Keevil, Brian G..(2014).A widely applicable plasma renin activity assay by LC-MS/MS with offline solid phase extraction.ANNALS OF CLINICAL BIOCHEMISTRY,51(3),409-411. |
MLA | Owen, Laura J.,et al."A widely applicable plasma renin activity assay by LC-MS/MS with offline solid phase extraction".ANNALS OF CLINICAL BIOCHEMISTRY 51.3(2014):409-411. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。