Arid
DOI10.1007/s00216-014-7753-4
Retention and selectivity of basic drugs on solid-phase extraction sorbents: Application to direct determination of beta-blockers in urine
Boonjob, Warunya1; Sklenarova, Hana1; Lara, Francisco J.2; Garcia-Campana, Ana M.2; Solich, Petr1
通讯作者Boonjob, Warunya
来源期刊ANALYTICAL AND BIOANALYTICAL CHEMISTRY
ISSN1618-2642
EISSN1618-2650
出版年2014
卷号406期号:17页码:4207-4215
英文摘要

Seven solid phase sorbent materials with reversed-phase, mixed-mode interactions (ion-exchange and reversed-phase), and molecularly imprinted polymers (MIP), namely Oasis HLB, Oasis MAX, Oasis MCX, Bond Elute Plexa, Bond Elute Plexa PAX, Bond Elute Plexa PCX, and SupelMIP sorbents, were investigated. The present study was focused on the retention and elution of pharmaceutically active substances based on several analyte-sorbent interaction properties. Basic drugs, such as beta-blockers (i.e., atenolol, pindolol, acebutolol, metoprolol, labetalol, and propranolol) were selected as the model compounds for this study. These compounds are frequently encountered in anti-doping tests. The extraction efficiencies of the individual sorbents were compared based on the recovery of known amounts of the targeted analytes in a metered elution volume (500 mu L) in three separate elution fractions. The elution efficiency of the total amount of the target analytes on various sorbents was not appreciably influenced by the volume of eluent required for complete elution. Based on the small matrix effects and clear baseline, SupelMIP was the most suitable sorbent for urine analysis. The relative analyte recoveries of the SPE-HPLC procedure proved satisfactory for the range from 94 % to 105 %, with an RSD ranging from 2 % to 4 %. The regression equations for all of the targeted compounds exhibited excellent linearity (r (2) > 0.9991) over the range of 10 to 1000 ng mL(-1). The limits of detection and quantification for the selected beta-blocker compounds in urine were in the ranges of 0.6 to 2.0 ng mL(-1) and 2.0 to 6.7 ng mL(-1), respectively.


英文关键词beta-Blockers SPE HPLC Biological samples MIP
类型Article
语种英语
国家Czech Republic ; Spain
收录类别SCI-E
WOS记录号WOS:000337787400017
WOS关键词MOLECULARLY IMPRINTED POLYMER ; RESTRICTED ACCESS MATERIALS ; TANDEM MASS-SPECTROMETRY ; LIQUID-CHROMATOGRAPHY ; SAMPLE PREPARATION ; BIOLOGICAL-FLUIDS ; TRACE LEVELS ; PLASMA ; PROPRANOLOL ; ISOFLAVONES
WOS类目Biochemical Research Methods ; Chemistry, Analytical
WOS研究方向Biochemistry & Molecular Biology ; Chemistry
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/180618
作者单位1.Charles Univ Prague, Fac Pharm, Dept Analyt Chem, Hradec Kralove 50005, Czech Republic;
2.Univ Granada, Dept Analyt Chem, Fac Sci, E-18071 Granada, Spain
推荐引用方式
GB/T 7714
Boonjob, Warunya,Sklenarova, Hana,Lara, Francisco J.,et al. Retention and selectivity of basic drugs on solid-phase extraction sorbents: Application to direct determination of beta-blockers in urine[J],2014,406(17):4207-4215.
APA Boonjob, Warunya,Sklenarova, Hana,Lara, Francisco J.,Garcia-Campana, Ana M.,&Solich, Petr.(2014).Retention and selectivity of basic drugs on solid-phase extraction sorbents: Application to direct determination of beta-blockers in urine.ANALYTICAL AND BIOANALYTICAL CHEMISTRY,406(17),4207-4215.
MLA Boonjob, Warunya,et al."Retention and selectivity of basic drugs on solid-phase extraction sorbents: Application to direct determination of beta-blockers in urine".ANALYTICAL AND BIOANALYTICAL CHEMISTRY 406.17(2014):4207-4215.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Boonjob, Warunya]的文章
[Sklenarova, Hana]的文章
[Lara, Francisco J.]的文章
百度学术
百度学术中相似的文章
[Boonjob, Warunya]的文章
[Sklenarova, Hana]的文章
[Lara, Francisco J.]的文章
必应学术
必应学术中相似的文章
[Boonjob, Warunya]的文章
[Sklenarova, Hana]的文章
[Lara, Francisco J.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。