Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1016/j.aca.2013.11.005 |
Quantitation of low concentrations of polysorbates in high protein concentration formulations by solid phase extraction and cobalt-thiocyanate derivatization | |
Kim, Justin; Qiu, Jinshu | |
通讯作者 | Qiu, Jinshu |
来源期刊 | ANALYTICA CHIMICA ACTA
![]() |
ISSN | 0003-2670 |
EISSN | 1873-4324 |
出版年 | 2014 |
卷号 | 806页码:144-151 |
英文摘要 | A spectrophotometric method was developed to quantify low polysorbate (PS) levels in biopharmaceutical formulations containing high protein concentrations. In the method, Oasis HLB solid phase extraction (SPE) cartridge was used to extract PS from high protein concentration formulations. After loading a sample, the cartridge was washed with 4M guanidine HCl and 10% (v/v) methanol, and the retained PS was eluted by acetonitrile. Following the evaporation of acetonitrile, aqueous cobalt-thiocyanate reagent was added to react with the polyoxyethylene oxide chain of polysorbates to form a blue colored PS-cobaltothiocyante complex. This colored complex was then extracted into methylene chloride and measured spectrophotometrically at 620 nm. The method performance was evaluated on three products containing 30-40 mg L-1 PS-20 and PS-80 in <= 70 g L-1 protein formulations. The method was specific (no matrix interference identified in three types of protein formulations), sensitive (quantitation limit of 10 mg L-1 PS) and robust with good precision (relative standard deviation <= 6.4%) and accuracy (spike recoveries from 95% to 101%). The linear range of the method for both PS-20 and PS-80 was 10 to 80 mg L-1 PS. By diluting samples with 6 M guanidine HCl and/or using different methylene chloride volumes to extract the colored complexes of standards and samples, the method could accurately and precisely quantify 40 mg L-1 PS in up to 300 g L-1 protein formulations. (C) 2013 Elsevier B.V. All rights reserved. |
英文关键词 | Polysorbate 20 Polysorbate 80 High protein concentration formulations Solid phase extraction Cobalt-thiocyanate Monoclonal antibody |
类型 | Article |
语种 | 英语 |
国家 | USA |
收录类别 | SCI-E |
WOS记录号 | WOS:000328568900014 |
WOS关键词 | PERFORMANCE LIQUID-CHROMATOGRAPHY ; AGITATION-INDUCED AGGREGATION ; LIGHT-SCATTERING DETECTION ; HUMAN GROWTH-HORMONE ; RECOMBINANT ; SURFACTANTS ; STABILIZATION ; STABILITY ; ANTIBODY ; BINDING |
WOS类目 | Chemistry, Analytical |
WOS研究方向 | Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/180611 |
作者单位 | Amgen Inc, Prod Attribute Sci, Thousand Oaks, CA 91320 USA |
推荐引用方式 GB/T 7714 | Kim, Justin,Qiu, Jinshu. Quantitation of low concentrations of polysorbates in high protein concentration formulations by solid phase extraction and cobalt-thiocyanate derivatization[J],2014,806:144-151. |
APA | Kim, Justin,&Qiu, Jinshu.(2014).Quantitation of low concentrations of polysorbates in high protein concentration formulations by solid phase extraction and cobalt-thiocyanate derivatization.ANALYTICA CHIMICA ACTA,806,144-151. |
MLA | Kim, Justin,et al."Quantitation of low concentrations of polysorbates in high protein concentration formulations by solid phase extraction and cobalt-thiocyanate derivatization".ANALYTICA CHIMICA ACTA 806(2014):144-151. |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Kim, Justin]的文章 |
[Qiu, Jinshu]的文章 |
百度学术 |
百度学术中相似的文章 |
[Kim, Justin]的文章 |
[Qiu, Jinshu]的文章 |
必应学术 |
必应学术中相似的文章 |
[Kim, Justin]的文章 |
[Qiu, Jinshu]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。