Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1002/2013JD020260 |
Intercomparison of surface energy flux measurement systems used during the HiWATER-MUSOEXE | |
Xu, Ziwei1; Liu, Shaomin1; Li, Xin2![]() | |
通讯作者 | Liu, Shaomin |
来源期刊 | JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES
![]() |
EISSN | 2169-8996 |
出版年 | 2013 |
卷号 | 118期号:23页码:13140-13157 |
英文摘要 | Agreement among instruments is very important for the Multi-Scale Observation Experiment on Evapotranspiration over heterogeneous land surfaces of The Heihe Watershed Allied Telemetry Experimental Research (HiWATER-MUSOEXE), particularly in regard to radiation and turbulent flux measurements. Before HiWATER-MUSOEXE was conducted, 20 eddy covariance (EC) system sets, 18 radiometer sets, and seven large aperture scintillometers (LASs) sets were intercompared over the Gobi desert between 14 and 24 May 2012. For radiometers, the four-component radiation measurements exhibited good agreementthe average root-mean-square error (RMSE) and mean relative error (MRE) for the net radiation were 10.38Wm(-2) and 1.24%, respectively. With regard to the EC systems, the best consistency for sensible heat fluxes was found among CSAT3 sonic anemometers and Li7500A/Li7500/EC150 combinations (average RMSE, 12.30Wm(-2) and MRE, -1.36%), followed by Gill sonic anemometers and Li7500A/Li7500 combinations when a proper angle of attack correction method was applied (average RMSE, 16.75W m(-2) and MRE, -5.52%). The sensible heat flux measured using different LASs agreed well with high correlation coefficientsthe average RMSE and MRE values were 10.26Wm(-2) and 5.48% for boundary layer scintillometer (BLS) 900, 16.32Wm(-2) and 10.47% for BLS450, and 14.38Wm(-2) and -3.72% for ZZLAS, respectively. The EC and LAS measurements were compared and agreed well over homogeneous underlying surfaces, which also indicated that the EC and LAS measurements would be comparable in the follow-up experiment. The intercomparison results can be used to determine instrument placement and are very helpful for subsequent data analysis. |
英文关键词 | radiometer eddy covariance system large aperture scintillometer |
类型 | Article |
语种 | 英语 |
国家 | Peoples R China |
收录类别 | SCI-E |
WOS记录号 | WOS:000330266500034 |
WOS关键词 | LARGE-APERTURE SCINTILLOMETER ; BALANCE EXPERIMENT EBEX-2000 ; EDDY-COVARIANCE ; QUALITY |
WOS类目 | Meteorology & Atmospheric Sciences |
WOS研究方向 | Meteorology & Atmospheric Sciences |
来源机构 | 中国科学院西北生态环境资源研究院 ; 北京师范大学 ; 中国农业大学 |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/178424 |
作者单位 | 1.Beijing Normal Univ, Sch Geog, State Key Lab Remote Sensing Sci, Beijing 100875, Peoples R China; 2.Chinese Acad Sci, Cold & Arid Reg Environm & Engn Res Inst, Lanzhou, Peoples R China; 3.China Agr Univ, Coll Resources & Environm Sci, Beijing 100094, Peoples R China |
推荐引用方式 GB/T 7714 | Xu, Ziwei,Liu, Shaomin,Li, Xin,et al. Intercomparison of surface energy flux measurement systems used during the HiWATER-MUSOEXE[J]. 中国科学院西北生态环境资源研究院, 北京师范大学, 中国农业大学,2013,118(23):13140-13157. |
APA | Xu, Ziwei.,Liu, Shaomin.,Li, Xin.,Shi, Shengjin.,Wang, Jiemin.,...&Ma, Mingguo.(2013).Intercomparison of surface energy flux measurement systems used during the HiWATER-MUSOEXE.JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES,118(23),13140-13157. |
MLA | Xu, Ziwei,et al."Intercomparison of surface energy flux measurement systems used during the HiWATER-MUSOEXE".JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES 118.23(2013):13140-13157. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。