Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1016/j.jchromb.2013.03.032 |
Simultaneous serum nicotine, cotinine, and trans-3 ’-hydroxycotinine quantitation with minimal sample volume for tobacco exposure status of solid organ transplant patients | |
Shu, Irene; Wang, Ping | |
通讯作者 | Wang, Ping |
来源期刊 | JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
![]() |
ISSN | 1570-0232 |
EISSN | 1873-376X |
出版年 | 2013 |
卷号 | 928页码:139-145 |
英文摘要 | Concentrations of nicotine and its metabolites in blood are indicative of patients’ current tobacco exposure, and their quantifications have been clinically applied to multiple assessments including demonstration of abstinence prior to heart-lung transplantation. For the purpose of transplant evaluation, the laboratory work up is extensive; thereby an assay with minimal sample volume is preferred. We developed and validated a rapid LC-MS/MS assay to simultaneously quantitate nicotine and its major metabolites, Cotinine and trans-3’-OH-cotinine (3-OH-Cot), in serum. 100 mu L of serum was spiked with deuterated internal standards and extracted by Oasis HLB solid phase extraction cartridge. Nicotine and metabolites in the reconstituted serum extract were separated by Agilent Eclipse XDB-C8 3.5 mu m 2.1 mm x 50 mm HPLC column within 4.7 min, and quantified by MS/MS with positive mode electro-spray ionization and multiple reaction monitoring. Ion suppression was insignificant, and extraction efficiency was 79-110% at 50 ng/mL for all compounds. Limit of detection was 1.0 ng/mL for nicotine and 3-OH-Cot, and <0.5 ng/mL for Cotinine. Linearity ranges for nicotine, cotinine and 3-OH-Cot were 2-100,2-1000, and 5-1000 ng/mL with recoveries of 86-115%. Within-day and twenty-day imprecision at nicotine/cotinine/3-OH-Cot levels of 22/150/90, 37/250/150, and 50/800/500 ng/mL were all 1.1-6.5%. The reconstituted serum extracts were stable for at least 7 days stored in the HPLC autosampler at 5 degrees C. Our method correlates well with alternative LC-MS/MS methods. We successfully developed and validated an LC-MS/MS assay to quantitate concentrations of nicotine and its metabolites in serum with minimal sample volume to assess tobacco exposure of heart-lung transplant patients. (C) 2013 Elsevier B.V. All rights reserved. |
英文关键词 | LC-MS/MS Nicotine Cotinine Trans-3 ’-Hydroxycotinine Transplant |
类型 | Article |
语种 | 英语 |
国家 | USA |
收录类别 | SCI-E |
WOS记录号 | WOS:000319236700019 |
WOS关键词 | TANDEM MASS-SPECTROMETRY ; LC-MS-MS ; LIVER-TRANSPLANTATION ; MONOAMINE-OXIDASE ; CIGARETTE-SMOKING ; ALKALOIDS ; METABOLITES ; SMOKERS ; PLASMA ; URINE |
WOS类目 | Biochemical Research Methods ; Chemistry, Analytical |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/178200 |
作者单位 | Methodist Hosp, Dept Pathol & Genom Med, Houston, TX 77030 USA |
推荐引用方式 GB/T 7714 | Shu, Irene,Wang, Ping. Simultaneous serum nicotine, cotinine, and trans-3 ’-hydroxycotinine quantitation with minimal sample volume for tobacco exposure status of solid organ transplant patients[J],2013,928:139-145. |
APA | Shu, Irene,&Wang, Ping.(2013).Simultaneous serum nicotine, cotinine, and trans-3 ’-hydroxycotinine quantitation with minimal sample volume for tobacco exposure status of solid organ transplant patients.JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES,928,139-145. |
MLA | Shu, Irene,et al."Simultaneous serum nicotine, cotinine, and trans-3 ’-hydroxycotinine quantitation with minimal sample volume for tobacco exposure status of solid organ transplant patients".JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES 928(2013):139-145. |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Shu, Irene]的文章 |
[Wang, Ping]的文章 |
百度学术 |
百度学术中相似的文章 |
[Shu, Irene]的文章 |
[Wang, Ping]的文章 |
必应学术 |
必应学术中相似的文章 |
[Shu, Irene]的文章 |
[Wang, Ping]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。