Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1016/j.jchromb.2012.12.032 |
Fast and sensitive UHPLC methods with fluorescence and tandem mass spectrometry detection for the determination of tetracycline antibiotics in surface waters | |
Skraskova, Karolina1; Santos, Lucia H. M. L. M.2; Satinsky, Dalibor1; Pena, Angelina3; Montenegro, Maria Conceicao B. S. M.2; Solich, Petr1; Novakova, Lucie1 | |
通讯作者 | Novakova, Lucie |
来源期刊 | JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
![]() |
ISSN | 1570-0232 |
EISSN | 1873-376X |
出版年 | 2013 |
卷号 | 927页码:201-208 |
英文摘要 | In this paper two fast and highly sensitive ultra-high performance liquid chromatography (UHPLC) methods for the determination of tetracycline antibiotics (oxytetracycline, tetracycline, doxycycline, demeclocycline, chlortetracycline, minocycline and degradation product epitetracycline) in surface waters have been developed using fluorescence (FL) and mass spectrometry (MS) detection. ACQUITY UPLC BEH C8 and ACQUITY CSH C18 columns were employed for FL and MS detection, respectively, both packed with 1.7 mu m particles. Mixed-mode separation mechanism of CSH (charged surface technology) sorbent was found particularly useful in analysis of TCs, which possess problematic amphoteric structures. The FL methodology was based on chelation of tetracyclines with calcium ions to perform on-column derivatisation. The developed methods were compared in the terms of validation parameters including linearity, sensitivity, precision and accuracy. The linearity range for FL detection was within 7 ng mL(-1) to 50 mu g mL(-1) with method limit of detection (MLOD) as low as 0.2 ng mL(-1) for most of the analytes. MS detection showed even higher sensitivity reaching MLOD of 0.003 ngmL(-1), which is the highest sensitivity reported so far in analysis of TCs. Matrix matched calibration curves in the range of 0.01-50 ng mL(-1) were used for quantification to compensate for matrix effects with the correlation coefficients demonstrating good linearity (0.9940-0.9999). The extraction of the antibiotics from surface waters was performed using solid phase extraction with Oasis HLB cartridges. Accuracy was expressed as recovery with values ranging from 96.52% to 127.30% and from 91.66% to 123.70% for FL and MS detection, respectively. (C) 2013 Elsevier B.V. All rights reserved. |
英文关键词 | UHPLC Mixed-mode stationary phases Tetracyclines MS/MS Surface waters Environmental contaminants |
类型 | Article |
语种 | 英语 |
国家 | Czech Republic ; Portugal |
收录类别 | SCI-E |
WOS记录号 | WOS:000318668000020 |
WOS关键词 | SOLID-PHASE EXTRACTION ; PERFORMANCE LIQUID-CHROMATOGRAPHY ; WASTE-WATER ; SULFONAMIDE ANTIBIOTICS ; ENVIRONMENTAL WATERS ; TRACE LEVELS ; SAMPLES ; GROUNDWATER ; SEPARATION ; CLEANUP |
WOS类目 | Biochemical Research Methods ; Chemistry, Analytical |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/178199 |
作者单位 | 1.Charles Univ Prague, Fac Pharm, Dept Analyt Chem, Hradec Kralove 50005, Czech Republic; 2.Univ Porto, Dept Chem, Fac Pharm, REQUIMTE, P-4050313 Oporto, Portugal; 3.Univ Coimbra, Fac Pharm, Ctr Pharmaceut Studies, Grp Hlth Surveillance, P-3000548 Coimbra, Portugal |
推荐引用方式 GB/T 7714 | Skraskova, Karolina,Santos, Lucia H. M. L. M.,Satinsky, Dalibor,et al. Fast and sensitive UHPLC methods with fluorescence and tandem mass spectrometry detection for the determination of tetracycline antibiotics in surface waters[J],2013,927:201-208. |
APA | Skraskova, Karolina.,Santos, Lucia H. M. L. M..,Satinsky, Dalibor.,Pena, Angelina.,Montenegro, Maria Conceicao B. S. M..,...&Novakova, Lucie.(2013).Fast and sensitive UHPLC methods with fluorescence and tandem mass spectrometry detection for the determination of tetracycline antibiotics in surface waters.JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES,927,201-208. |
MLA | Skraskova, Karolina,et al."Fast and sensitive UHPLC methods with fluorescence and tandem mass spectrometry detection for the determination of tetracycline antibiotics in surface waters".JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES 927(2013):201-208. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。