Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1016/j.chroma.2013.06.042 |
Analysis of organophosphate flame retardant diester metabolites in human urine by liquid chromatography electrospray ionisation tandem mass spectrometry | |
Van den Eede, Nele1; Neels, Hugo1; Jorens, Philippe G.2; Covaci, Adrian1 | |
通讯作者 | Covaci, Adrian |
来源期刊 | JOURNAL OF CHROMATOGRAPHY A
![]() |
ISSN | 0021-9673 |
EISSN | 1873-3778 |
出版年 | 2013 |
卷号 | 1303页码:48-53 |
英文摘要 | A new analytical method was developed for the determination of dialkyl and diaryl phosphates (DAPs), which are metabolites of organophosphate triesters (PFRs), in human urine. Target DAPs included dibutyl phosphate (DBP), diphenyl phosphate (DPHP), bis(2-butoxyethyl) phosphate (BBOEP), bis(2-chloroethyl) phosphate (BCEP), bis(1-chloro-2-propyl) phosphate (BCPP), and bis(1,3-dichloro-2-propyl) phosphate (BDCIPP). Sample preparation was based on solid phase extraction using a weak anion exchange sorbent (Oasis WAX). Although several instrumental techniques have been tested, best results were obtained with reversed phase liquid chromatography-negative electrospray ionisation tandem mass spectrometry (LC-ESI-MS/MS) taking the total analysis time into account. Method accuracy at 3 ng/mL in pooled urine ranged between 69 and 119% (recovery), while inter-day imprecision (as relative standard deviation) was <31%. The performance of the LC-MS/MS method was compared to a method based on gas chromatography-electron impact tandem mass spectrometry (GC-MS/MS) and a good correlation (Pearson r=0.82,p < 0.01) between the results of these two methods was obtained for DPHP. LC-MS/MS analysis was more suitable for DPHP and BBOEP with respective method limits of quantification (mLOQ) of 0.3 and 0.15 ng/mL. In contrast, GC-MS/MS had a better sensitivity for BCEP, BCIPP, and BDCIPP, their respective mLOQs being 0.1, 0.06, 0.02 ng/mL, compared to 1.2, 3.7, and 0.5 ng/mL by LC-MS/MS. A set of urine samples from volunteers was analysed, in which DPHP was the major DAP metabolite. A significant increase of DPHP levels was observed in the group of smokers (geometric mean of 1.55 ng/mL) compared to the non-smokers (geometric mean of 0.88 ng/mL). Metabolic transformation of triphenyl phosphate to DPHP by metabolic enzymes induced in smokers could be an explanation for this observation. (c) 2013 Elsevier B.V. All rights reserved. |
英文关键词 | Dialkyl phosphates Diphenyl phosphate Phosphorus flame retardants PFR Metabolites Urine |
类型 | Article |
语种 | 英语 |
国家 | Belgium |
收录类别 | SCI-E |
WOS记录号 | WOS:000322562200006 |
WOS类目 | Biochemical Research Methods ; Chemistry, Analytical |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/178189 |
作者单位 | 1.Univ Antwerp, Toxicol Ctr, B-2610 Antwerp, Belgium; 2.Univ Antwerp, Univ Antwerp Hosp, B-2630 Edegem, Belgium |
推荐引用方式 GB/T 7714 | Van den Eede, Nele,Neels, Hugo,Jorens, Philippe G.,et al. Analysis of organophosphate flame retardant diester metabolites in human urine by liquid chromatography electrospray ionisation tandem mass spectrometry[J],2013,1303:48-53. |
APA | Van den Eede, Nele,Neels, Hugo,Jorens, Philippe G.,&Covaci, Adrian.(2013).Analysis of organophosphate flame retardant diester metabolites in human urine by liquid chromatography electrospray ionisation tandem mass spectrometry.JOURNAL OF CHROMATOGRAPHY A,1303,48-53. |
MLA | Van den Eede, Nele,et al."Analysis of organophosphate flame retardant diester metabolites in human urine by liquid chromatography electrospray ionisation tandem mass spectrometry".JOURNAL OF CHROMATOGRAPHY A 1303(2013):48-53. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。