Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1016/j.chroma.2013.06.028 |
Rapid screening of drugs of abuse in human urine by high-performance liquid chromatography coupled with high resolution and high mass accuracy hybrid linear ion trap-Orbitrap mass spectrometry | |
Li, Xiaowen1,2; Shen, Baohua1; Jiang, Zheng3; Huang, Yi1; Zhuo, Xianyi1 | |
通讯作者 | Zhuo, Xianyi |
来源期刊 | JOURNAL OF CHROMATOGRAPHY A
![]() |
ISSN | 0021-9673 |
出版年 | 2013 |
卷号 | 1302页码:95-104 |
英文摘要 | A novel analytical toxicology method has been developed for the analysis of drugs of abuse in human urine by using a high resolution and high mass accuracy hybrid linear ion trap-Orbitrap mass spectrometer (LTQ-Orbitrap-MS). This method allows for the detection of different drugs of abuse, including amphetamines, cocaine, opiate alkaloids, cannabinoids, hallucinogens and their metabolites. After solid-phase extraction with Oasis HLB cartridges, spiked urine samples were analysed by HPLC/LTQ-Orbitrap-MS using an electrospray interface in positive ionisation mode, with resolving power of 30,000 full width at half maximum (FWHM). Gradient elution off of a Hypersil Gold PFP column (50 mm x 2.1 mm) allowed to resolve 65 target compounds and 3 internal standards in a total chromatographic run time of 20 min. Validation of this method consisted of confirmation of identity, selectivity, linearity, limit of detection (LOD), lowest limits of quantification (LLOQ), accuracy, precision, extraction recovery and matrix effect. The regression coefficients (r(2)) for the calibration curves (LLOQ 100 ng/mL) in the study were >= 0.99. The LODs for 65 validated compounds were better than 5 ng/ml except for 4 compounds. The relative standard deviation (RSD), which was used to estimate repeatability at three concentrations, was always less than 15%. The recovery of extraction and matrix effects were above 50 and 70%, respectively. Mass accuracy was always better than 2 ppm, corresponding to a maximum mass error of 0.8 millimass units (mmu). The accurate masses of characteristic fragments were obtained by collisional experiments for a more reliable identification of the analytes. Automated data analysis and reporting were performed using ToxID software with an exact mass database. This procedure was then successfully applied to analyse drugs of abuse in a real urine sample from subject who was assumed to be drug addict. Crown Copyright (C) 2013 Published by Elsevier B.V. All rights reserved. |
英文关键词 | Drugs of abuse Liquid chromatography Hybrid linear ion trap-Orbitrap mass spectrometer Urine samples |
类型 | Article |
语种 | 英语 |
国家 | Peoples R China |
收录类别 | SCI-E |
WOS记录号 | WOS:000322349700013 |
WOS关键词 | SOLID-PHASE EXTRACTION ; DOPING CONTROL ; LC-MS/MS ; SIMULTANEOUS QUANTIFICATION ; ORAL FLUID ; METABOLITES ; COCAINE ; IDENTIFICATION ; MORPHINE ; HAIR |
WOS类目 | Biochemical Research Methods ; Chemistry, Analytical |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/178188 |
作者单位 | 1.Minist Justice, Inst Forens Sci, Dept Forens Toxicol, Shanghai Key Lab Forens Med, Shanghai, Peoples R China; 2.Fudan Univ, Shanghai Med Coll, Dept Forens Sci, Shanghai 200032, Peoples R China; 3.Thermo Fisher Sci, Shanghai 201206, Peoples R China |
推荐引用方式 GB/T 7714 | Li, Xiaowen,Shen, Baohua,Jiang, Zheng,et al. Rapid screening of drugs of abuse in human urine by high-performance liquid chromatography coupled with high resolution and high mass accuracy hybrid linear ion trap-Orbitrap mass spectrometry[J],2013,1302:95-104. |
APA | Li, Xiaowen,Shen, Baohua,Jiang, Zheng,Huang, Yi,&Zhuo, Xianyi.(2013).Rapid screening of drugs of abuse in human urine by high-performance liquid chromatography coupled with high resolution and high mass accuracy hybrid linear ion trap-Orbitrap mass spectrometry.JOURNAL OF CHROMATOGRAPHY A,1302,95-104. |
MLA | Li, Xiaowen,et al."Rapid screening of drugs of abuse in human urine by high-performance liquid chromatography coupled with high resolution and high mass accuracy hybrid linear ion trap-Orbitrap mass spectrometry".JOURNAL OF CHROMATOGRAPHY A 1302(2013):95-104. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。