Arid
DOI10.1007/s11419-012-0155-4
High-throughput determination of barbiturates in human plasma using on-line column-switching ultra-fast liquid chromatography-tandem mass spectrometry
Lee, Xiao-Pen1; Kumazawa, Takeshi1; Hasegawa, Chika2; Arinobu, Tetsuya3; Seno, Hiroshi4; Suzuki, Osamu5; Sato, Keizo1
通讯作者Kumazawa, Takeshi
来源期刊FORENSIC TOXICOLOGY
ISSN1860-8965
出版年2013
卷号31期号:1页码:9-20
英文摘要

A high-throughput method was developed for determinations of eight barbiturates (barbital, allobarbital, phenobarbital, cyclobarbital, amobarbital, secobarbital, thiopental, and thiamylal) in human plasma by on-line column-switching ultra-fast liquid chromatography-tandem mass spectrometry (MS-MS). Plasma samples (100 mu l) spiked with the eight barbiturates and 5-(4-methylphenyl)-5-phenylhydantoin (internal standard) were diluted with 300 mu l of 13.3 mM ammonium acetate/acetonitrile (33:67, v/v). After centrifugation and filtration, the clear supernatant was injected directly onto the extraction column (Oasis HLB cartridge column). The following procedure was fully automated. The analytes retained on the extraction column were eluted by backflushing of the extraction column and introduced onto the analytical column (Phenomenex Onyx monolithic C-18 column, 100 mm x 4.6 mm i.d.) by column switching. Quantification was performed by multiple reaction monitoring with negative-ion atmospheric pressure chemical ionization. Good peak separation and peak shapes of the eight drugs were achieved within an analysis time of 3 min, including the extraction time. All drugs spiked into plasma showed recoveries of 80-93 %. The regression equations for the eight drugs showed excellent linearities in the range of 10-5000 ng/ml of plasma, and the limits of detection ranged from 1.0 to 10 ng/ml. The lower and upper limits of quantitation were 10-50 ng/ml and 5000 ng/ml, respectively. Intraday and interday coefficients of variation for all the drugs were not > 9.1 %. The accuracies of quantitation were 92.0-108 %. The method was successfully applied to determination of the level of amobarbital in human plasma after its oral administration to a volunteer.


英文关键词Barbiturate drugs Monolithic column On-line column switching UFLC-MS-MS Human plasma Phenobarbital
类型Article
语种英语
国家Japan
收录类别SCI-E
WOS记录号WOS:000313801900003
WOS关键词SOLID-PHASE EXTRACTION ; GAS-CHROMATOGRAPHY ; DRUG ; METABOLITES ; XENOBIOTICS ; VALIDATION
WOS类目Toxicology
WOS研究方向Toxicology
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/177180
作者单位1.Showa Univ, Dept Legal Med, Sch Med, Shinagawa Ku, Tokyo 1428555, Japan;
2.Toho Univ, Dept Legal Med, Sch Med, Tokyo, Japan;
3.Aichi Med Univ, Dept Chem, Sch Med, Nagakute, Aichi, Japan;
4.Aichi Med Univ, Dept Legal Med, Sch Med, Nagakute, Aichi, Japan;
5.Hamamatsu Univ Sch Med, Dept Legal Med, Hamamatsu, Shizuoka 4313192, Japan
推荐引用方式
GB/T 7714
Lee, Xiao-Pen,Kumazawa, Takeshi,Hasegawa, Chika,et al. High-throughput determination of barbiturates in human plasma using on-line column-switching ultra-fast liquid chromatography-tandem mass spectrometry[J],2013,31(1):9-20.
APA Lee, Xiao-Pen.,Kumazawa, Takeshi.,Hasegawa, Chika.,Arinobu, Tetsuya.,Seno, Hiroshi.,...&Sato, Keizo.(2013).High-throughput determination of barbiturates in human plasma using on-line column-switching ultra-fast liquid chromatography-tandem mass spectrometry.FORENSIC TOXICOLOGY,31(1),9-20.
MLA Lee, Xiao-Pen,et al."High-throughput determination of barbiturates in human plasma using on-line column-switching ultra-fast liquid chromatography-tandem mass spectrometry".FORENSIC TOXICOLOGY 31.1(2013):9-20.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Lee, Xiao-Pen]的文章
[Kumazawa, Takeshi]的文章
[Hasegawa, Chika]的文章
百度学术
百度学术中相似的文章
[Lee, Xiao-Pen]的文章
[Kumazawa, Takeshi]的文章
[Hasegawa, Chika]的文章
必应学术
必应学术中相似的文章
[Lee, Xiao-Pen]的文章
[Kumazawa, Takeshi]的文章
[Hasegawa, Chika]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。