Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1016/j.chroma.2012.03.078 |
Highly sensitive fast determination of entecavir in rat urine by means of hydrophilic interaction chromatography-ultra-high-performance liquid chromatography-tandem mass spectrometry | |
Novakova, Lucie1; Gottvald, Tomas1; Vickova, Hana1; Trejtnar, Frantisek2; Mandikova, Jana2; Solich, Petr1 | |
通讯作者 | Novakova, Lucie |
来源期刊 | JOURNAL OF CHROMATOGRAPHY A
![]() |
ISSN | 0021-9673 |
出版年 | 2012 |
卷号 | 1259页码:237-243 |
英文摘要 | Entecavir is a deoxyguanosine nucleotide antiviral agent with the activity against hepatitis B virus (HBV). The agent possesses a polar structure, which is predetermined for hydrophilic interaction chromatography (HILIC). Novel, fast and sensitive HILIC-UHPLC method developed in this study included separation from matrix component on BEH Amide stationary phase by isocratic elution using binary mobile phase composed of acetonitrile/5 mM ammonium acetate pH 4.0 (75:25) at flow-rate 0.3 ml/min. Analysis under RP-UHPLC conditions was also possible on BEN C18 stationary phase with mostly aqueous binary mobile phase composed of (4:96) acetonitrile/0.01% formic acid. The comparison of sensitivity of the two UHPLC-MS/MS methods both using selected reaction monitoring (SRM) for quantitation revealed only slightly higher sensitivity for HILIC determination, however much better method linearity, repeatability and accuracy. HILIC separation mode provided also more convenient conditions for straightforward coupling with solid phase extraction (SPE). Entecavir was extracted on Oasis HLB cartridge (1 ml, 30 mg) and eluted by 75% acetonitrile in water, which is actually the HILIC mobile phase used in this study. Therefore the evaporation/reconstitution step was omitted, which substantially accelerated the sample preparation step. The method was validated using stable isotopically labeled internal standard entecavir-C-2(13) N-15, Which is the most appropriate internal standard. Validation results demonstrated good method accuracy (with < 5% error, and 26% at LOQ), recovery (87-114%), precision (<4% RSD), selectivity and sensitivity (LOQ = 100 pg/ml). The matrix effects determined by both post-column infusion method as well as post-extraction addition method were negligible (<15%). (C) 2012 Elsevier B.V. All rights reserved. |
英文关键词 | Entecavir Hydrophilic interaction chromatography (HILIC) UHPLC MS/MS Solid phase extraction Rat urine |
类型 | Article |
语种 | 英语 |
国家 | Czech Republic |
收录类别 | SCI-E |
WOS记录号 | WOS:000309566500022 |
WOS关键词 | LABELED INTERNAL STANDARD ; HUMAN PLASMA ; VALIDATION ; EXTRACTION ; ANALYTE ; MS/MS |
WOS类目 | Biochemical Research Methods ; Chemistry, Analytical |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/173397 |
作者单位 | 1.Charles Univ Prague, Fac Pharm, Dept Analyt Chem, Hradec Kralove 50005, Czech Republic; 2.Charles Univ Prague, Fac Pharm, Dept Pharmacol & Toxicol, Hradec Kralove 50005, Czech Republic |
推荐引用方式 GB/T 7714 | Novakova, Lucie,Gottvald, Tomas,Vickova, Hana,et al. Highly sensitive fast determination of entecavir in rat urine by means of hydrophilic interaction chromatography-ultra-high-performance liquid chromatography-tandem mass spectrometry[J],2012,1259:237-243. |
APA | Novakova, Lucie,Gottvald, Tomas,Vickova, Hana,Trejtnar, Frantisek,Mandikova, Jana,&Solich, Petr.(2012).Highly sensitive fast determination of entecavir in rat urine by means of hydrophilic interaction chromatography-ultra-high-performance liquid chromatography-tandem mass spectrometry.JOURNAL OF CHROMATOGRAPHY A,1259,237-243. |
MLA | Novakova, Lucie,et al."Highly sensitive fast determination of entecavir in rat urine by means of hydrophilic interaction chromatography-ultra-high-performance liquid chromatography-tandem mass spectrometry".JOURNAL OF CHROMATOGRAPHY A 1259(2012):237-243. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。