英文摘要

Bottom-up proteomics requires the digestion of proteins into peptides by processes that use salts for denaturing and buffering purposes. These salts need to be removed prior to mass spectrometry analysis to reduce ion suppression: solid-phase extraction (SPE) is a commonly used strategy. There are many commercially available SPE sorbent types and sizes, which are generally provided with manufacturer recommendations for use, including protein loading capacity. We found that these general suggestions were often not ideal, and our data suggest that context-specific evaluation of sorbent type and amount can improve reproducibility. Specifically, the universal Oasis HLB sorbent provided better retention of the more hydrophilic peptides than the traditional C-18 reversed-phase SPE, but it did so at the expense of an increased loss of the more hydrophobic peptides. We found that increasing the amount of the C-18 sorbent beyond the manufacturer’s guidelines decreased breakthrough (i.e., increased retention) of 12 hydrophilic, identifiable peptides without loss of hydrophobic peptides. This procedure was robust in a 96-well plate format. (C) 2012 Elsevier Inc. All rights reserved.


英文关键词SPE Proteomics Trypsin Plasma
类型Article
语种英语
国家USA
收录类别SCI-E
WOS记录号WOS:000305045000014
WOS关键词MASS-SPECTROMETRY ; LIQUID-CHROMATOGRAPHY ; BIOMARKER DISCOVERY ; QUANTIFICATION
WOS类目Biochemical Research Methods ; Biochemistry & Molecular Biology ; Chemistry, Analytical
WOS研究方向Biochemistry & Molecular Biology ; Chemistry
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/171176
作者单位1.Brigham & Womens Hosp, Dept Neurosurg, Boston, MA 02115 USA;
2.Harvard Univ, Sch Med, Dept Surg, Boston, MA 02115 USA
推荐引用方式
GB/T 7714
Guo, Xiaofeng,Kristal, Bruce S.. The use of underloaded C-18 solid-phase extraction plates increases reproducibility of analysis of tryptic peptides from unfractionated human plasma[J],2012,426(1):86-90.
APA Guo, Xiaofeng,&Kristal, Bruce S..(2012).The use of underloaded C-18 solid-phase extraction plates increases reproducibility of analysis of tryptic peptides from unfractionated human plasma.ANALYTICAL BIOCHEMISTRY,426(1),86-90.
MLA Guo, Xiaofeng,et al."The use of underloaded C-18 solid-phase extraction plates increases reproducibility of analysis of tryptic peptides from unfractionated human plasma".ANALYTICAL BIOCHEMISTRY 426.1(2012):86-90.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Guo, Xiaofeng]的文章
[Kristal, Bruce S.]的文章
百度学术
百度学术中相似的文章
[Guo, Xiaofeng]的文章
[Kristal, Bruce S.]的文章
必应学术
必应学术中相似的文章
[Guo, Xiaofeng]的文章
[Kristal, Bruce S.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。