Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1097/FTD.0b013e31820176d6 |
Simultaneous Determination of Warfarin and 7-Hydroxywarfarin Enantiomers by High-Performance Liquid Chromatography With Ultraviolet Detection | |
Miura, Masatomo1; Okuyama, Shin2; Kato, Shoutaro1; Kagaya, Hideaki1; Murata, Atsunobu1; Komatsuda, Atsushi2; Wakui, Hideki2; Sawada, Kenichi2 | |
通讯作者 | Miura, Masatomo |
来源期刊 | THERAPEUTIC DRUG MONITORING
![]() |
ISSN | 0163-4356 |
出版年 | 2011 |
卷号 | 33期号:1页码:108-114 |
英文摘要 | Warfarin is administered clinically as a racemic mixture of two enantiomers, (R)-warfarin and (S)-warfarin. (S)-Warfarin has more potent anticoagulant activity than (R)-warfarin and is metabolized mainly to (S)-7-hydroxywarfarin by CYP2C9. A simple, rapid, and sensitive high-performance liquid chromatography method with ultraviolet detection was developed for the simultaneous quantitative determination of the (R)- and (S)-enantiomers of warfarin and 7-hydroxywarfarin in human plasma. Analytes and the internal standard (p-chlorowarfarin) were separated using a mobile phase of 0.5% KH(2)PO(4) (pH 3.5)-methanol (41: 59, v/v) on a Chiral CD-Ph column at a flow rate of 0.5 mL/min and were detected at a ultraviolet absorbance of 305 nm. Analysis required 200 mu L of plasma and involved a simple and rapid solid-phase extraction with an Oasis HLB cartridge, which gave high recovery (greater than 91.8%) and good selectivity for all analytes. The lower limit of quantification for the (R)- and (S)-enantiomers of warfarin and 7-hydroxywarfarin was 2.5 ng/mL for each analyte. Inter-and intraday coefficients of variation for all analytes were less than 14.2% and accuracies were within 6.6% over the linear range. Our results indicate that this method is applicable to the simultaneous monitoring of the enantiomers of warfarin and 7-hydroxywarfarin in human plasma. The S/R-enantiomer ratio of warfarin and the (S)-warfarin/(S)-7-hydroxywarfarin ratio 3 hours after administration in 67 CYP2C9* 1/*1 patients ranged from 0.24 to 0.75 and from 1.83 to 19.02, respectively, whereas these ratios in a CYP2C9* 3/*3 patient were 1.12 and 17.02, respectively. |
英文关键词 | warfarin 7-hydroxywarfarin enantiomer HPLC CYP2C9 |
类型 | Article |
语种 | 英语 |
国家 | Japan |
收录类别 | SCI-E |
WOS记录号 | WOS:000286180600017 |
WOS关键词 | DRUG-INTERACTIONS ; HUMAN PLASMA ; S-WARFARIN ; R-WARFARIN ; POLYMORPHISMS ; CYP2C9 ; METABOLISM ; SULFAMETHOXAZOLE ; TRIMETHOPRIM ; PATIENT |
WOS类目 | Medical Laboratory Technology ; Pharmacology & Pharmacy ; Toxicology |
WOS研究方向 | Medical Laboratory Technology ; Pharmacology & Pharmacy ; Toxicology |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/170711 |
作者单位 | 1.Akita Univ Hosp, Dept Pharm, Akita 0108543, Japan; 2.Akita Univ, Grad Sch Med, Dept Hematol Nephrol & Rheumatol, Akita 010, Japan |
推荐引用方式 GB/T 7714 | Miura, Masatomo,Okuyama, Shin,Kato, Shoutaro,et al. Simultaneous Determination of Warfarin and 7-Hydroxywarfarin Enantiomers by High-Performance Liquid Chromatography With Ultraviolet Detection[J],2011,33(1):108-114. |
APA | Miura, Masatomo.,Okuyama, Shin.,Kato, Shoutaro.,Kagaya, Hideaki.,Murata, Atsunobu.,...&Sawada, Kenichi.(2011).Simultaneous Determination of Warfarin and 7-Hydroxywarfarin Enantiomers by High-Performance Liquid Chromatography With Ultraviolet Detection.THERAPEUTIC DRUG MONITORING,33(1),108-114. |
MLA | Miura, Masatomo,et al."Simultaneous Determination of Warfarin and 7-Hydroxywarfarin Enantiomers by High-Performance Liquid Chromatography With Ultraviolet Detection".THERAPEUTIC DRUG MONITORING 33.1(2011):108-114. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。