Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1016/j.talanta.2010.10.036 |
Three optimized and validated (using accuracy profiles) LC methods for the determination of pentamidine and new analogs in rat plasma | |
Hambye, S.1; Stanicki, D.2; Colet, J. -M.3; Aliouat, E. M.4; Vanden Eynde, J. J.2; Blankert, B.1,5 | |
通讯作者 | Blankert, B. |
来源期刊 | TALANTA
![]() |
ISSN | 0039-9140 |
EISSN | 1873-3573 |
出版年 | 2011 |
卷号 | 83期号:3页码:832-839 |
英文摘要 | Three novel LC-UV methods for the determination of pentamidine (PTMD) and two of its new analogs in rat plasma are described. The chromatographic conditions (wavelength, acetonitrile percentage in the mobile phase, internal standard) were optimized to have an efficient selectivity. A pre-step of extraction was simultaneously developed for each compound. For PTMD, a solid phase extraction (SPE) with Oasis HLB cartridges was selected, while for the analogs we used protein precipitation with acetonitrile. SPE for PTMD gave excellent results in terms of extraction yield (99.7 +/- 2.8) whereas the recoveries for the analogs were not so high but were reproducible as well (64.6 +/- 2.6 and 36.8 +/- 1.6 for analog 1 and 2, respectively). By means of a recent strategy based on accuracy profiles (beta-expectation tolerance interval), the methods were successfully validated. beta was fixed at 95% and the acceptability limits at +/- 15% as recommended by the FDA. The method was successfully validated for PTMD (29.6-586.54 ng/mL), analog 1(74.23-742.3 ng/mL) and analog 2 (178.12-890.6 ng/mL). The first concentration level tested was considered as the LLOQ(lower limit of quantification) for PTMD and analog 1 whereas for analog 2, the LLOQ was not the first level tested and was raised to 178.12 ng/ml. (C) 2010 Elsevier BM. All rights reserved. |
英文关键词 | Pentamidine Validation Accuracy profiles SPE LC Benzamidines |
类型 | Article |
语种 | 英语 |
国家 | Belgium ; France |
收录类别 | SCI-E |
WOS记录号 | WOS:000286549900019 |
WOS关键词 | QUANTITATIVE ANALYTICAL PROCEDURES ; LIQUID-CHROMATOGRAPHIC DETERMINATION ; SFSTP PROPOSAL ; HARMONIZATION ; STRATEGIES ; SERUM ; BISBENZAMIDINES ; ASSAY ; HPLC ; AIDS |
WOS类目 | Chemistry, Analytical |
WOS研究方向 | Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/170667 |
作者单位 | 1.Univ Mons, Fac Med & Pharm, Lab Pharmaceut Anal, B-7000 Mons, Belgium; 2.Univ Mons, Fac Sci, Organ Chem Lab, B-7000 Mons, Belgium; 3.Univ Mons, Fac Med & Pharm, Lab Human Biol & Toxicol, B-7000 Mons, Belgium; 4.Univ Lille Nord France, CNRS, INSERM,U1019,UMR 8402,CIIL, Lab Biol & Divers Eukaryot Emerging Pathogens BDE, F-59019 Lille, France; 5.Univ Libre Bruxelles, Inst Pharm, Lab Instrumental Anal & Bioelectrochem, B-1050 Brussels, Belgium |
推荐引用方式 GB/T 7714 | Hambye, S.,Stanicki, D.,Colet, J. -M.,et al. Three optimized and validated (using accuracy profiles) LC methods for the determination of pentamidine and new analogs in rat plasma[J],2011,83(3):832-839. |
APA | Hambye, S.,Stanicki, D.,Colet, J. -M.,Aliouat, E. M.,Vanden Eynde, J. J.,&Blankert, B..(2011).Three optimized and validated (using accuracy profiles) LC methods for the determination of pentamidine and new analogs in rat plasma.TALANTA,83(3),832-839. |
MLA | Hambye, S.,et al."Three optimized and validated (using accuracy profiles) LC methods for the determination of pentamidine and new analogs in rat plasma".TALANTA 83.3(2011):832-839. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。