Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1016/j.microc.2010.11.007 |
On-line sorptive preconcentration platform incorporating a readily exchangeable Oasis HLB extraction micro-cartridge for trace cadmium and lead determination by flow injection-flame atomic absorption spectrometry | |
Anthemidis, Aristidis N.1; Giakisikli, Georgia1; Xidia, Sofia1; Miro, Manuel2 | |
通讯作者 | Anthemidis, Aristidis N. |
来源期刊 | MICROCHEMICAL JOURNAL
![]() |
ISSN | 0026-265X |
出版年 | 2011 |
卷号 | 98期号:1页码:66-71 |
英文摘要 | A simple, sensitive and inexpensive flow injection solid phase extraction (SPE) system was developed for automatic determination of trace level concentrations of metals. The potentials of this novel scheme, coupled to flame atomic absorption spectrometry (FAAS), were demonstrated for trace cadmium and lead determination in environmental water samples. The method was based on on-line chelate complex formation of target species with ammonium diethyldithiophosphate (DDTP). retention onto the surface of reversed-phase poly(divinylbenzene-N-vinylpyrrolidone) co-polymeric beads (Oasis HLB) and elution with methanol prior to atomization. A special PVC adapter was designed for easy and rapid replacement of the commercially available SPE cartridge. All main chemical and hydrodynamic parameters affecting the complex formation, sorption and elution of the analyte were optimized thoroughly. Moreover, the effect of potential interfering species occurring in environmental samples was also explored. For 90 s preconcentration time, enhancement factors of 155 and 180, detection limits (3s) of 0.09 mu g L(-1) and 0.9 mu g L(-1) and relative standard deviations (R.S.D.) of 2.9% (at 4.0 mu g L(-1)) and 2.6% (at 20.0 mu g L(-1)) were obtained for cadmium and lead, respectively, with a sample throughput of 24 h(-1). The measurement trueness of the developed method was evaluated by analyzing a certified reference material and spiked environmental water samples. The proposed method is well suited to detect the target elements at concentration levels below the maximum allowed concentrations endorsed by the European Framework Directive (2008/105/EC) in inland and coastal waters. (C) 2010 Elsevier B.V. All rights reserved. |
英文关键词 | Oasis-HLB Flow injection Reversed-phase sorbent extraction Atomic absorption spectrometry Cadmium Lead |
类型 | Article |
语种 | 英语 |
国家 | Greece ; Spain |
收录类别 | SCI-E |
WOS记录号 | WOS:000288977200012 |
WOS关键词 | SOLID-PHASE EXTRACTION ; SEQUENTIAL INJECTION ; BIOLOGICAL SAMPLES ; SORBENT EXTRACTION ; MASS SPECTROMETRY ; CARBON NANOTUBES ; WATER SAMPLES ; COPPER ; ELEMENTS ; METALS |
WOS类目 | Chemistry, Analytical |
WOS研究方向 | Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/169673 |
作者单位 | 1.Aristotle Univ Thessaloniki, Fac Sci, Dept Chem, Analyt Chem Lab, GR-54006 Thessaloniki, Greece; 2.Univ Balearic Isl, Fac Sci, Dept Chem, E-07071 Palma de Mallorca, Spain |
推荐引用方式 GB/T 7714 | Anthemidis, Aristidis N.,Giakisikli, Georgia,Xidia, Sofia,et al. On-line sorptive preconcentration platform incorporating a readily exchangeable Oasis HLB extraction micro-cartridge for trace cadmium and lead determination by flow injection-flame atomic absorption spectrometry[J],2011,98(1):66-71. |
APA | Anthemidis, Aristidis N.,Giakisikli, Georgia,Xidia, Sofia,&Miro, Manuel.(2011).On-line sorptive preconcentration platform incorporating a readily exchangeable Oasis HLB extraction micro-cartridge for trace cadmium and lead determination by flow injection-flame atomic absorption spectrometry.MICROCHEMICAL JOURNAL,98(1),66-71. |
MLA | Anthemidis, Aristidis N.,et al."On-line sorptive preconcentration platform incorporating a readily exchangeable Oasis HLB extraction micro-cartridge for trace cadmium and lead determination by flow injection-flame atomic absorption spectrometry".MICROCHEMICAL JOURNAL 98.1(2011):66-71. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。