DOI | 10.1016/j.chroma.2010.09.057 |
Mixed-mode and reversed-phase liquid chromatography-tandem mass spectrometry methodologies to study composition and base hydrolysis of polysorbate 20 and 80 | |
Hewitt, Daniel1; Alvarez, Melissa1; Robinson, Kathryn1; Ji, Junyan2; Wang, Y. John2; Kao, Yung-Hsiang1; Zhang, Taylor1 | |
通讯作者 | Hewitt, Daniel |
来源期刊 | JOURNAL OF CHROMATOGRAPHY A
![]() |
ISSN | 0021-9673 |
出版年 | 2011 |
卷号 | 1218期号:15页码:2138-2145 |
英文摘要 | Polysorbate 20 (polyoxyethylenesorbitan monolaurate) and polysorbate 80 (polyoxyethylenesorbitan monooleate) used in protein drug formulations are complex mixtures that have been difficult to characterize. Here, two HPLC methods are used with evaporative light scattering detection (ELSD) and mass spectrometry (MS) to characterize polysorbate from commercial vendors. The first HPLC method used a mixed-mode stationary phase (Waters Oasis MAX, mixed-mode anion exchange and reversed-phase sorbent) with a step gradient to quantify both the total polyoxyethylene sorbitan ester and polyoxyethylene sorbitan (POE sorbitan, a non-surfactant) in polysorbate. The results indicated POE sorbitan was present from 16.0 to 27.6 and 11.1 to 14.5% (w/w) in polysorbate 20 and 80, respectively. The second HPLC method used a reversed-phase stationary phase (Zorbax SB-300 C-8) with a shallow gradient to separate, identify, and quantify the multiple ester species present in polysorbate. For all lots of polysorbate 20 analyzed, only 18-23% of the material was the expected structure, polyoxyethylenesorbitan monolaurate. Up to 40% and 70% (w/w) di- and triesters were found in polysorbate 20 and polysorbate 80 respectively. Likewise, polyoxyethylenesorbitan monooleate accounted for only 20% of polysorbate 80. A variability of 3-5% was observed for each ester species between multiple lots of polysorbate 20. The reversed-phase method was then used to determine the rate of hydrolysis for each polyoxyethylene sorbitan ester of polysorbate 20 in basic solution at room temperature. Increasing rates of hydrolysis were observed with decreasing aliphatic chain lengths in polysorbate 20. (C) 2010 Elsevier B.V. All rights reserved. |
英文关键词 | Polysorbate Evaporative light scattering Mass spectrometry Hydrolysis |
类型 | Article |
语种 | 英语 |
国家 | USA |
收录类别 | SCI-E |
WOS记录号 | WOS:000289331200027 |
WOS关键词 | LIGHT-SCATTERING DETECTION ; HUMAN GROWTH-HORMONE ; SURFACTANTS ; FORMULATIONS ; QUANTITATION ; DOCETAXEL ; KINETICS ; VEHICLE ; MS |
WOS类目 | Biochemical Research Methods ; Chemistry, Analytical |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/169017 |
作者单位 | 1.Genentech Inc, Dept Prot Analyt Chem, San Francisco, CA 94080 USA; 2.Genentech Inc, Dept Late Stage Pharmaceut & Proc Dev, San Francisco, CA 94080 USA |
推荐引用方式 GB/T 7714 | Hewitt, Daniel,Alvarez, Melissa,Robinson, Kathryn,et al. Mixed-mode and reversed-phase liquid chromatography-tandem mass spectrometry methodologies to study composition and base hydrolysis of polysorbate 20 and 80[J],2011,1218(15):2138-2145. |
APA | Hewitt, Daniel.,Alvarez, Melissa.,Robinson, Kathryn.,Ji, Junyan.,Wang, Y. John.,...&Zhang, Taylor.(2011).Mixed-mode and reversed-phase liquid chromatography-tandem mass spectrometry methodologies to study composition and base hydrolysis of polysorbate 20 and 80.JOURNAL OF CHROMATOGRAPHY A,1218(15),2138-2145. |
MLA | Hewitt, Daniel,et al."Mixed-mode and reversed-phase liquid chromatography-tandem mass spectrometry methodologies to study composition and base hydrolysis of polysorbate 20 and 80".JOURNAL OF CHROMATOGRAPHY A 1218.15(2011):2138-2145. |