Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1093/chromsci/49.5.412 |
Quantitative Determination of Imatinib in Human Plasma with High-Performance Liquid Chromatography and Ultraviolet Detection | |
Miura, Masatomo1; Takahashi, Naoto2; Sawada, Ken-ichi2 | |
通讯作者 | Miura, Masatomo |
来源期刊 | JOURNAL OF CHROMATOGRAPHIC SCIENCE
![]() |
ISSN | 0021-9665 |
EISSN | 1945-239X |
出版年 | 2011 |
卷号 | 49期号:5页码:412-415 |
英文摘要 | A simple and sensitive high-performance liquid chromatography (HPLC) method was developed to quantitate imatinib in human plasma. Imatinib and the internal standard dasatinib were separated using a mobile phase of 0.5% KH2PO4 (pH3.5)-acetonitrile-methanol (55:25:20, v/v/v) on a CAPCELL PAK C18 MG II column (250 mm x 4.6 mm) at a flow rate of 0.5 ml/min and measurement at UV 265 nm. Analysis required 100 mu L of plasma and involved a solid phase extraction with an Oasis HLB cartridge, which gave recoveries of imatinib from 73% to 76%. The lower limit of quantification for imatinib was 10 ng/ml. The linear range of this assay was between 10 and 5000 ng/mL (regression line r(2) > 0.9992). Inter- and intra-day coefficients of variation were less than 11.9% and accuracies were within 8.3% over the linear range. The plasma concentrations of imatinib obtained by our present method were almost the same as those assayed by an LC-MS-MS method at the bray Research Center, Inc. This method can be applied effectively to measure imatinib concentrations in clinical samples. |
类型 | Article |
语种 | 英语 |
国家 | Japan |
收录类别 | SCI-E |
WOS记录号 | WOS:000289922200012 |
WOS关键词 | MAIN METABOLITE CGP-74588 ; DRUG ST1571 GLEEVEC(TM) ; QUANTIFICATION ; SAFETY ; PHARMACOKINETICS ; EFFICACY ; MESYLATE |
WOS类目 | Biochemical Research Methods ; Chemistry, Analytical |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/169014 |
作者单位 | 1.Akita Univ Hosp, Dept Pharm, Akita 0108543, Japan; 2.Akita Univ Hosp, Grad Sch Med, Dept Hematol Nephrol & Rheumatol, Akita 0108543, Japan |
推荐引用方式 GB/T 7714 | Miura, Masatomo,Takahashi, Naoto,Sawada, Ken-ichi. Quantitative Determination of Imatinib in Human Plasma with High-Performance Liquid Chromatography and Ultraviolet Detection[J],2011,49(5):412-415. |
APA | Miura, Masatomo,Takahashi, Naoto,&Sawada, Ken-ichi.(2011).Quantitative Determination of Imatinib in Human Plasma with High-Performance Liquid Chromatography and Ultraviolet Detection.JOURNAL OF CHROMATOGRAPHIC SCIENCE,49(5),412-415. |
MLA | Miura, Masatomo,et al."Quantitative Determination of Imatinib in Human Plasma with High-Performance Liquid Chromatography and Ultraviolet Detection".JOURNAL OF CHROMATOGRAPHIC SCIENCE 49.5(2011):412-415. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。