Arid
DOI10.1007/s10337-011-2123-2
Bleeding Evaluation of Different SPE Cartridges on Clean-Up of Atrazine From Aqueous Samples Containing Organic Matter
Lima, Diana L. D.1,2,3; Silva, Carla Patricia1,2; Esteves, Valdemar I.1,2
通讯作者Esteves, Valdemar I.
来源期刊CHROMATOGRAPHIA
ISSN0009-5893
出版年2011
卷号74期号:9-10页码:725-729
英文摘要

Bleeding of the SPE column, resulting in sample contamination, is not often a focus of attention. However, such problems can be relevant in sample purification procedures. In this work SPE method was optimized in order to clean up an atrazine soil aqueous solution, which is usually needed to quantify this pollutant to follow its sorption into soils. During this optimization a sorbent bleeding was witnessed, resulting in sample contamination. This unexpected event led us to the bleeding evaluation of different SPE cartridges commonly used in analytical chemistry laboratory experimental procedures. Using the same conditioning and elution protocol in five different commercial SPE cartridges, only the Oasis cartridge did not present any sorbent leaching and subsequent eluate contamination.


英文关键词Solid-phase extraction Bleeding Atrazine
类型Article
语种英语
国家Portugal
收录类别SCI-E
WOS记录号WOS:000297165100007
WOS关键词SOLID-PHASE EXTRACTION ; SORPTION BEHAVIOR ; SOILS ; PESTICIDES ; ADSORPTION ; WATER ; DESORPTION ; PHENOLS
WOS类目Biochemical Research Methods ; Chemistry, Analytical
WOS研究方向Biochemistry & Molecular Biology ; Chemistry
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/167603
作者单位1.Univ Aveiro, CESAM, P-3810193 Aveiro, Portugal;
2.Univ Aveiro, Dept Chem, P-3810193 Aveiro, Portugal;
3.Super Sch Hlth Technol Coimbra, Dept Complementary Sci, P-3040854 Coimbra, Portugal
推荐引用方式
GB/T 7714
Lima, Diana L. D.,Silva, Carla Patricia,Esteves, Valdemar I.. Bleeding Evaluation of Different SPE Cartridges on Clean-Up of Atrazine From Aqueous Samples Containing Organic Matter[J],2011,74(9-10):725-729.
APA Lima, Diana L. D.,Silva, Carla Patricia,&Esteves, Valdemar I..(2011).Bleeding Evaluation of Different SPE Cartridges on Clean-Up of Atrazine From Aqueous Samples Containing Organic Matter.CHROMATOGRAPHIA,74(9-10),725-729.
MLA Lima, Diana L. D.,et al."Bleeding Evaluation of Different SPE Cartridges on Clean-Up of Atrazine From Aqueous Samples Containing Organic Matter".CHROMATOGRAPHIA 74.9-10(2011):725-729.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Lima, Diana L. D.]的文章
[Silva, Carla Patricia]的文章
[Esteves, Valdemar I.]的文章
百度学术
百度学术中相似的文章
[Lima, Diana L. D.]的文章
[Silva, Carla Patricia]的文章
[Esteves, Valdemar I.]的文章
必应学术
必应学术中相似的文章
[Lima, Diana L. D.]的文章
[Silva, Carla Patricia]的文章
[Esteves, Valdemar I.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。