英文摘要

We report airborne measurements of CO2 column abundance conducted during two 2009 campaigns using a 2.05 mu m laser absorption spectrometer. The two flight campaigns took place in the California Mojave desert and in Oklahoma. The integrated path differential absorption (IPDA) method is used for the CO2 column mixing ratio retrievals. This instrument and the data analysis methodology provide insight into the capabilities of the IPDA method for both airborne measurements and future global-scale CO2 measurements from low Earth orbit pertinent to the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons mission. The use of a favorable absorption line in the CO2 2 mu m band allows the on-line frequency to be displaced two (surface pressure) half-widths from line center, providing high sensitivity to the lower tropospheric CO2. The measurement repeatability and measurement precision are in good agreement with predicted estimates. We also report comparisons with airborne in situ measurements conducted during the Oklahoma campaign. (C) 2011 Optical Society of America


类型Article
语种英语
国家USA
收录类别SCI-E
WOS记录号WOS:000290431000017
WOS关键词LIDAR MEASUREMENTS ; HETERODYNE-DETECTION ; MU-M ; OPTIMIZATION ; BANDS ; (CO2)-C-12-O-16 ; PARAMETERS ; SPECTRA ; REGIONS ; CM(-1)
WOS类目Optics
WOS研究方向Optics
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/167097
作者单位1.CALTECH, Jet Prop Lab, Pasadena, CA 91109 USA;
2.Lockheed Martin Coherent Technol, Louisville, CO 80027 USA;
3.Natl Inst Aerosp, Hampton, VA 23666 USA;
4.NASA, Langley Res Ctr, Hampton, VA 23681 USA
推荐引用方式
GB/T 7714
Spiers, Gary D.,Menzies, Robert T.,Jacob, Joseph,et al. Atmospheric CO2 measurements with a 2 mu m airborne laser absorption spectrometer employing coherent detection[J],2011,50(14):2098-2111.
APA Spiers, Gary D..,Menzies, Robert T..,Jacob, Joseph.,Christensen, Lance E..,Phillips, Mark W..,...&Browell, Edward V..(2011).Atmospheric CO2 measurements with a 2 mu m airborne laser absorption spectrometer employing coherent detection.APPLIED OPTICS,50(14),2098-2111.
MLA Spiers, Gary D.,et al."Atmospheric CO2 measurements with a 2 mu m airborne laser absorption spectrometer employing coherent detection".APPLIED OPTICS 50.14(2011):2098-2111.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Spiers, Gary D.]的文章
[Menzies, Robert T.]的文章
[Jacob, Joseph]的文章
百度学术
百度学术中相似的文章
[Spiers, Gary D.]的文章
[Menzies, Robert T.]的文章
[Jacob, Joseph]的文章
必应学术
必应学术中相似的文章
[Spiers, Gary D.]的文章
[Menzies, Robert T.]的文章
[Jacob, Joseph]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。