Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1016/j.jchromb.2010.06.031 |
Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of goserelin in rabbit plasma | |
Kim, Min Kyung1; Lee, Tae Ho1; Suh, Joon Hyuk1; Eom, Han Young1; Min, Jung Won1; Yeom, Hyesun1; Kim, Unyong1; Jung, Hyung Joon2; Cha, Kyung Hoi2; Choi, Yong Seok3,4; Youm, Jeong-Rok1; Han, Sang Beom1 | |
通讯作者 | Han, Sang Beom |
来源期刊 | JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
![]() |
ISSN | 1570-0232 |
EISSN | 1873-376X |
出版年 | 2010 |
卷号 | 878期号:24页码:2235-2242 |
英文摘要 | A rapid and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESI-MS/MS) was developed and validated for the determination of goserelin in rabbit plasma. Various parameters affecting plasma sample preparation, LC separation, and MS/MS detection were investigated, and optimized conditions were identified. Acidified plasma samples were applied to Oasis (R) HLB solid-phase extraction (SPE) cartridges. Extracted samples were evaporated under a stream of nitrogen and then reconstituted with 100 mu L mobile phase A. The separation was achieved on a Capcell-Pak C18 (2.0 mm x 150 mm, 5 mu m, AQ type) column with a gradient elution of solvent A(0.05% acetic acid in deionized water/acetonitrile = 85/15; v/v) and solvent B (acetonitrile) at a flow rate of 250 mu L/min. The LC-MS/MS system was equipped with an electrospray ion source operating in positive ion mode. Multiple-reaction monitoring (MRM) of the precursor-product ion transitions consisted of m/z 635.7 -> m/z 607.5 for goserelin and m/z 424.0 -> m/z 292.1 for cephapirin (internal standard). The proposed method was validated by assessing specificity, linearity, limit of quantification (LOQ), intra-and inter-day precision and accuracy, recovery, and stability. Linear calibration curves were obtained in the concentration range of 0.1-20 ng/mL (the correlation coefficients were above 0.99). The LOQ of the method was 0.1 ng/mL Results obtained from the validation study of goserelin showed good accuracy and precision at concentrations of 0.1, 1, 5, 10, and 20 ng/mL. The validated method was successfully applied to a pharmacokinetic study of goserelin after a single subcutaneous injection of 3.6 mg of goserelin in healthy white rabbits. (C) 2010 Elsevier B.V. All rights reserved. |
英文关键词 | Goserelin Peptide Liquid chromatography-tandem mass spectrometry Rabbit plasma Pharmacokinetic study |
类型 | Article |
语种 | 英语 |
国家 | South Korea ; USA |
收录类别 | SCI-E |
WOS记录号 | WOS:000281290400008 |
WOS关键词 | HORMONE-RELEASING HORMONE ; PROSTATE-CANCER ; PHARMACOKINETIC PROPERTIES ; DECAPEPTIDE CETRORELIX ; PEPTIDE-HORMONES ; ANALOG ; QUANTIFICATION ; PROTEINS ; DEGRADATION ; SENSITIVITY |
WOS类目 | Biochemical Research Methods ; Chemistry, Analytical |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/165068 |
作者单位 | 1.Chung Ang Univ, Dept Pharmaceut Anal, Coll Pharm, Seoul 156756, South Korea; 2.Dongkook Pharm Co Ltd, Suwon 443270, Gyeonggi Do, South Korea; 3.Univ Delaware, Dept Chem Engn, Newark, DE 19711 USA; 4.Univ Delaware, Delaware Biotechnol Inst, Newark, DE 19711 USA |
推荐引用方式 GB/T 7714 | Kim, Min Kyung,Lee, Tae Ho,Suh, Joon Hyuk,et al. Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of goserelin in rabbit plasma[J],2010,878(24):2235-2242. |
APA | Kim, Min Kyung.,Lee, Tae Ho.,Suh, Joon Hyuk.,Eom, Han Young.,Min, Jung Won.,...&Han, Sang Beom.(2010).Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of goserelin in rabbit plasma.JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES,878(24),2235-2242. |
MLA | Kim, Min Kyung,et al."Development and validation of a liquid chromatography-tandem mass spectrometry method for the determination of goserelin in rabbit plasma".JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES 878.24(2010):2235-2242. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。