Arid
DOI10.1016/j.jchromb.2010.03.0041
Quantification of corticosteroids in bovine urine using selective solid phase extraction and reversed-phase liquid chromatography/tandem mass spectrometry
Tolgyesi, Adam1,2; Sharma, Virender K.3; Kovacsics, Lorena1,2; Fekete, Jeno4
通讯作者Tolgyesi, Adam
来源期刊JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
ISSN1570-0232
出版年2010
卷号878期号:19页码:1471-1479
英文摘要

This paper presents the development of a simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to determine corticosteroids in bovine urine sample malt ices. This method uses a single phase extraction (SPE) for cleaning of the sample with an Oasis MAX cartridge at pH 9 0-9 5 and elution by a neutral organic solvent (acetonitrile/dichloromethane), followed by separation on a GEMINI C18 column in the gradient mode with acetate buffer (pH 4 1)/methanol A triple quadrupole mass spectrometer equipped with a multimode ion source, set to negative atmospheric pressure chemical ionization (APCI) in the multiple reaction monitoring mode was used for detection The main advantage of this method over other commonly used methods includes the use of SPE with a low volume cartridge for sample preparation and no ion suppression effects from matrix components of the urine samples in the LC-MS/MS analysis This allowed a reduction the quantification limits (decision limits, CC alpha) for the first time to (1 mu g/L and 02 mu g/L for tnamcmolone and flumethasone, respectively) The developed method was validated in accordance with the European Union Commission Decision 2002/657 EC. The recoveries and within-laboratory reproducibility varied from 77% to 115% and 87% to 107 5%, respectively, at 2, 3, and 4 mu g/L levels of corticosteroids The relative standard deviation (RSD) of the measurements was lower than 30% The decision limit was calculated by multiplying the signal-to-noise ratio by 3 and the obtained values were in the range of 0 1-1 0 mu g/L, confirmed by the analysis of twenty blank samples, which were spiked at the desired concentrations The detection capability was calculated by the addition of the decision limit and the standard deviation followed by multiplication by 1 64 of the within-laboratory reproducibility at 2 mu g/L of corticosteroids. The method was applied to four urine samples, giving concentrations of prednisolone (PRED) residues in the range from 03 to 09 mu g/L. (C) 2010 Elsevier B V All rights reserved


英文关键词Corticosteroid Liquid chromatography-tandem mass spectrometry Ion-suppression Urine Validation
类型Article
语种英语
国家Hungary ; USA
收录类别SCI-E
WOS记录号WOS:000278649400006
WOS关键词GAS-CHROMATOGRAPHY ; QUANTITATIVE-DETERMINATION ; SYNTHETIC CORTICOSTEROIDS ; HORSE URINE ; PLASMA ; VALIDATION ; STEROIDS ; DRUGS ; DERIVATIZATION ; DEXAMETHASONE
WOS类目Biochemical Research Methods ; Chemistry, Analytical
WOS研究方向Biochemistry & Molecular Biology ; Chemistry
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/165067
作者单位1.Food Toxicol Natl Reference Lab, Cent Agr Off Food, H-1095 Budapest, Hungary;
2.Food Toxicol Natl Reference Lab, Feed Safety Directorate, H-1095 Budapest, Hungary;
3.Florida Inst Technol, Dept Chem, Melbourne, FL 32901 USA;
4.Budapest Univ Technol & Econ, Dept Inorgan & Analyt Chem, H-1111 Budapest, Hungary
推荐引用方式
GB/T 7714
Tolgyesi, Adam,Sharma, Virender K.,Kovacsics, Lorena,et al. Quantification of corticosteroids in bovine urine using selective solid phase extraction and reversed-phase liquid chromatography/tandem mass spectrometry[J],2010,878(19):1471-1479.
APA Tolgyesi, Adam,Sharma, Virender K.,Kovacsics, Lorena,&Fekete, Jeno.(2010).Quantification of corticosteroids in bovine urine using selective solid phase extraction and reversed-phase liquid chromatography/tandem mass spectrometry.JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES,878(19),1471-1479.
MLA Tolgyesi, Adam,et al."Quantification of corticosteroids in bovine urine using selective solid phase extraction and reversed-phase liquid chromatography/tandem mass spectrometry".JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES 878.19(2010):1471-1479.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Tolgyesi, Adam]的文章
[Sharma, Virender K.]的文章
[Kovacsics, Lorena]的文章
百度学术
百度学术中相似的文章
[Tolgyesi, Adam]的文章
[Sharma, Virender K.]的文章
[Kovacsics, Lorena]的文章
必应学术
必应学术中相似的文章
[Tolgyesi, Adam]的文章
[Sharma, Virender K.]的文章
[Kovacsics, Lorena]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。