Arid
DOI10.1021/es902256m
Evaluation of the Use of Performance Reference Compounds in an Oasis-HLB Adsorbent Based Passive Sampler for Improving Water Concentration Estimates of Polar Herbicides in Freshwater
Mazzella, Nicolas1; Lissalde, Sophie1; Moreira, Sylvia1; Delmas, Francois1; Mazellier, Patrick2; Huckins, James N.3
通讯作者Mazzella, Nicolas
来源期刊ENVIRONMENTAL SCIENCE & TECHNOLOGY
ISSN0013-936X
出版年2010
卷号44期号:5页码:1713-1719
英文摘要

Passive samplers such as the Polar Organic Chemical Integrative Sampler (POCIS) are useful tools for monitoring trace levels of polar organic chemicals in aquatic environments. The use of performance reference compounds (PRC) spiked into the POCIS adsorbent for in situ calibration may improve the semiquantitative nature of water concentration estimates based on this type of sampler. In this work, deuterium labeled atrazine-desisopropyl (DIA-d5) was chosen as PRC because of its relatively high fugacity from Oasis HLB (the POCIS adsorbent used) and our earlier evidence of its isotropic exchange. In situ calibration of POCIS spiked with DIA-d5 was performed, and the resulting time-weighted average concentration estimates were compared with similar values from an automatic sampler equipped with Oasis HLB cartridges. Before PRC correction, water concentration estimates based on POCIS data sampling rates from a laboratory calibration exposure were systematically lower than the reference concentrations obtained with the automatic sampler. Use of the DIA-d5 PRC data to correct POCIS sampling rates narrowed differences between corresponding values derived from the two methods. Application of PRCs for in situ calibration seems promising for improving POCIS-derived concentration estimates of polar pesticides. However, careful attention must be paid to the minimization of matrix effects when the quantification is performed by HPLC-ESI-MS/MS.


类型Article
语种英语
国家France ; USA
收录类别SCI-E
WOS记录号WOS:000274842000032
WOS关键词SEMIPERMEABLE-MEMBRANE DEVICES ; CHEMICAL INTEGRATIVE SAMPLER ; TANDEM MASS-SPECTROMETRY ; ORGANIC CONTAMINANTS ; AQUATIC ENVIRONMENTS ; SURFACE-WATER ; IN-SITU ; CALIBRATION ; POLLUTANTS ; MATRIX
WOS类目Engineering, Environmental ; Environmental Sciences
WOS研究方向Engineering ; Environmental Sciences & Ecology
来源机构United States Geological Survey
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/164068
作者单位1.Cemagref, UR REBX, F-33612 Gazinet, Cestas, France;
2.Univ Bordeaux, IUT Perigueux, CNRS UMR 5255, LPTC ISM, F-24019 Perigueux, France;
3.US Geol Survey, Columbia Environm Res Ctr, Columbia, MO 65201 USA
推荐引用方式
GB/T 7714
Mazzella, Nicolas,Lissalde, Sophie,Moreira, Sylvia,et al. Evaluation of the Use of Performance Reference Compounds in an Oasis-HLB Adsorbent Based Passive Sampler for Improving Water Concentration Estimates of Polar Herbicides in Freshwater[J]. United States Geological Survey,2010,44(5):1713-1719.
APA Mazzella, Nicolas,Lissalde, Sophie,Moreira, Sylvia,Delmas, Francois,Mazellier, Patrick,&Huckins, James N..(2010).Evaluation of the Use of Performance Reference Compounds in an Oasis-HLB Adsorbent Based Passive Sampler for Improving Water Concentration Estimates of Polar Herbicides in Freshwater.ENVIRONMENTAL SCIENCE & TECHNOLOGY,44(5),1713-1719.
MLA Mazzella, Nicolas,et al."Evaluation of the Use of Performance Reference Compounds in an Oasis-HLB Adsorbent Based Passive Sampler for Improving Water Concentration Estimates of Polar Herbicides in Freshwater".ENVIRONMENTAL SCIENCE & TECHNOLOGY 44.5(2010):1713-1719.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Mazzella, Nicolas]的文章
[Lissalde, Sophie]的文章
[Moreira, Sylvia]的文章
百度学术
百度学术中相似的文章
[Mazzella, Nicolas]的文章
[Lissalde, Sophie]的文章
[Moreira, Sylvia]的文章
必应学术
必应学术中相似的文章
[Mazzella, Nicolas]的文章
[Lissalde, Sophie]的文章
[Moreira, Sylvia]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。