VALIDATED QUANTITATIVE SIMULTANEOUS DETERMINATION OF COCAINE, OPIATES AND AMPHETAMINES IN SERUM BY U-HPLC COUPLED TO TANDEM MASS SPECTROMETRY
Dubois, N.1; Debrus, B.2,3; Hubert, Ph.2,3; Charlier, C.1,3
通讯作者Dubois, N.
来源期刊ACTA CLINICA BELGICA
ISSN1784-3286
EISSN2295-3337
出版年2010
卷号65页码:75-84
英文摘要

Simultaneous determination of cocaine, opiates and amphetamines in serum by ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS) allowed to replace favourably gas chromatography coupled to mass spectrometry (GC-MS) used until now in our laboratory. It had to answer to accreditation demand according to Belgian Accreditation (Be lac).


Twenty-one deutereted internal standards were added to 500 mu L of serum. Sample pre-treatment consisted of solid-phase extraction using Oasis MCX cartridges 1mL, 30mg (Waters, Zellik, Belgium). Chromatographic separation was done on an Acquity HSS T3 column (2.1 x 100mm, 1.8 mu m, Waters). Mobile phase consisted of pH 3 ammonium formate buffer and of methanol adjusted to pH 3 with formic acid. Compounds were next analysed by tandem mass spectrometry operated in the multiple reaction monitoring (MRM) mode. The method was validated using total error approach.


Twenty-seven drugs were separated in 19 minutes. The linearity of the method was acceptable in the validated range of concentrations. The bias and the relative standard deviations for repeatability and intermediate precision were acceptable. Lower and upper beta-expectation tolerance limits did not exceed the acceptance limits of 20% for concentrations upper than 20 mu g/L and 50% for concentrations lower than 20 mu g/L. The limits of quantitation were tower than 7 mu g/L for all compounds.


英文关键词Cocaine opiates amphetamines UHPLC-MS/MS method validation total error
类型Article ; Proceedings Paper
语种英语
国家Belgium
收录类别SCI-E ; CPCI-S
WOS记录号WOS:000276999400014
WOS关键词SFSTP PROPOSAL ; WHOLE-BLOOD ; HARMONIZATION ; STRATEGIES ; METABOLITES ; HEROIN
WOS类目Medicine, General & Internal
WOS研究方向General & Internal Medicine
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/162904
作者单位1.CHU Sart Tilman, Serv Toxicol Clin Medicolegale Environm & Entrepr, B-4000 Liege, Belgium;
2.Univ Liege, Chim Analyt Serv, Dept Pharm, B-4000 Liege, Belgium;
3.Univ Liege, CIRM, B-4000 Liege, Belgium
推荐引用方式
GB/T 7714
Dubois, N.,Debrus, B.,Hubert, Ph.,et al. VALIDATED QUANTITATIVE SIMULTANEOUS DETERMINATION OF COCAINE, OPIATES AND AMPHETAMINES IN SERUM BY U-HPLC COUPLED TO TANDEM MASS SPECTROMETRY[J],2010,65:75-84.
APA Dubois, N.,Debrus, B.,Hubert, Ph.,&Charlier, C..(2010).VALIDATED QUANTITATIVE SIMULTANEOUS DETERMINATION OF COCAINE, OPIATES AND AMPHETAMINES IN SERUM BY U-HPLC COUPLED TO TANDEM MASS SPECTROMETRY.ACTA CLINICA BELGICA,65,75-84.
MLA Dubois, N.,et al."VALIDATED QUANTITATIVE SIMULTANEOUS DETERMINATION OF COCAINE, OPIATES AND AMPHETAMINES IN SERUM BY U-HPLC COUPLED TO TANDEM MASS SPECTROMETRY".ACTA CLINICA BELGICA 65(2010):75-84.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Dubois, N.]的文章
[Debrus, B.]的文章
[Hubert, Ph.]的文章
百度学术
百度学术中相似的文章
[Dubois, N.]的文章
[Debrus, B.]的文章
[Hubert, Ph.]的文章
必应学术
必应学术中相似的文章
[Dubois, N.]的文章
[Debrus, B.]的文章
[Hubert, Ph.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。