Arid
DOI10.1016/j.jchromb.2009.10.017
Sensitive and selective method for the determination of bisphenol-A and triclosan in serum and urine as pentafluorobenzoate-derivatives using GC-ECNI/MS
Geens, Tinne1; Neels, Hugo1; Covaci, Adrian1,2
通讯作者Covaci, Adrian
来源期刊JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
ISSN1570-0232
EISSN1873-376X
出版年2009
卷号877期号:31页码:4042-4046
英文摘要

The development and validation of an analytical method is presented for the determination of bisphenol-A (BPA) and triclosan (TCS), two ubiquitous contaminants, in serum and urine. The glucuronidated metabolites were first turned into their free forms to determine total BPA and TCS. The determination consisted of a solid-phase extraction on Oasis HLB cartridges followed by an extractive derivatization with pentafluorobenzoylchloride. The extract was then purified on 10% (w/w) acidified silica and analyzed by gas chromatography-mass spectrometry in electron-capture negative ionization mode. Monitored ions were m/z 616 and 406 for BPA and m/z 482 and 287 for TCS, respectively. Limits of quantification were 0.5 ng/mL in serum and 0.2 ng/mL in urine for BPA and 0.1 ng/mL in serum and 0.05 ng/mL in urine for TCS. Method recoveries were between 76 and 110%, while repeatability was below 20%. The method was applied on 20 serum and 20 urine samples. The detection frequency in serum was 10% and 55% for BPA and TCS, respectively. BPA and TCS could be detected in all urine samples with median concentrations of 1.25 ng BPA/mL (range 0.58-5.20 ng/mL) and 1.71 ng TCS/mL (0.18-672 ng/mL). (C) 2009 Elsevier B.V. All rights reserved.


英文关键词Bisphenol-A Triclosan Serum Urine Pentafluorobenzoylchloride-derivatives GC-MS
类型Article
语种英语
国家Belgium
收录类别SCI-E
WOS记录号WOS:000272317600016
WOS关键词IONIZATION MASS-SPECTROMETRY ; SOLID-PHASE EXTRACTION ; HPLC-MS/MS METHOD ; LIQUID-CHROMATOGRAPHY ; ENVIRONMENTAL PHENOLS ; HUMAN EXPOSURE ; US POPULATION ; HUMANS ; MILK
WOS类目Biochemical Research Methods ; Chemistry, Analytical
WOS研究方向Biochemistry & Molecular Biology ; Chemistry
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/161432
作者单位1.Univ Antwerp, Toxicol Ctr, Dept Pharmaceut Sci, B-2610 Antwerp, Belgium;
2.Univ Antwerp, Dept Biol, Lab Ecophysiol Biochem & Toxicol, B-2610 Antwerp, Belgium
推荐引用方式
GB/T 7714
Geens, Tinne,Neels, Hugo,Covaci, Adrian. Sensitive and selective method for the determination of bisphenol-A and triclosan in serum and urine as pentafluorobenzoate-derivatives using GC-ECNI/MS[J],2009,877(31):4042-4046.
APA Geens, Tinne,Neels, Hugo,&Covaci, Adrian.(2009).Sensitive and selective method for the determination of bisphenol-A and triclosan in serum and urine as pentafluorobenzoate-derivatives using GC-ECNI/MS.JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES,877(31),4042-4046.
MLA Geens, Tinne,et al."Sensitive and selective method for the determination of bisphenol-A and triclosan in serum and urine as pentafluorobenzoate-derivatives using GC-ECNI/MS".JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES 877.31(2009):4042-4046.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Geens, Tinne]的文章
[Neels, Hugo]的文章
[Covaci, Adrian]的文章
百度学术
百度学术中相似的文章
[Geens, Tinne]的文章
[Neels, Hugo]的文章
[Covaci, Adrian]的文章
必应学术
必应学术中相似的文章
[Geens, Tinne]的文章
[Neels, Hugo]的文章
[Covaci, Adrian]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。