Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1016/j.chroma.2009.06.076 |
Simultaneous determination of eleven quinolones in animal feed by liquid chromatography with fluorescence and ultraviolet absorbance detection | |
Galarini, Roberta; Fioroni, Laura; Angelucci, Federico; Tovo, Gloria R.; Cristofani, Elisa | |
通讯作者 | Galarini, Roberta |
来源期刊 | JOURNAL OF CHROMATOGRAPHY A
![]() |
ISSN | 0021-9673 |
出版年 | 2009 |
卷号 | 1216期号:46页码:8158-8164 |
英文摘要 | A rapid and simple multi-residue procedure is described for assaying eleven quinolones (cinoxacin, ciprofloxacin, danofloxacin, difloxacin, enrofloxacin, flumequine, marbofloxacin, nalidixic acid, norfloxacin, oxolinic acid and sarafloxacin) in feeds at sub-additive levels (1-5 mg kg(-1)). Five grams of sample were extracted by a metaphosphoric acid/acetonitrile mixture (70/30, v/v) and purified onto OASIS HLB cartridges. The determination was achieved by liquid chromatography (LC) using a GEMINI 08 analytical column both with fluorescence detection (FD) and photodiode-array (DAD). Limits of detection for each drug were in the range 0.04-0.8 mg kg(-1). Above the limit of quantification (LOQ), in poultry feed the recoveries were from 69 to 98% with relative standard deviations less than or equal 10%. Finally the measurement uncertainty was estimated using the bottom-up approach. (C) 2009 Elsevier B.V. All rights reserved. |
英文关键词 | Quinolones Feed Liquid chromatography Validation Uncertainty |
类型 | Article |
语种 | 英语 |
国家 | Italy |
收录类别 | SCI-E |
WOS记录号 | WOS:000271585800019 |
WOS关键词 | TANDEM MASS-SPECTROMETRY ; OXOLINIC ACID ; FISH FEED ; VALIDATION ; FLUOROQUINOLONES ; RESIDUES ; SAMPLES ; MUSCLE ; ELECTROPHORESIS ; ANTIBACTERIALS |
WOS类目 | Biochemical Research Methods ; Chemistry, Analytical |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/161419 |
作者单位 | Ist Zooprofilatt Sperimentale Umbria & Marche, I-06126 Perugia, Italy |
推荐引用方式 GB/T 7714 | Galarini, Roberta,Fioroni, Laura,Angelucci, Federico,et al. Simultaneous determination of eleven quinolones in animal feed by liquid chromatography with fluorescence and ultraviolet absorbance detection[J],2009,1216(46):8158-8164. |
APA | Galarini, Roberta,Fioroni, Laura,Angelucci, Federico,Tovo, Gloria R.,&Cristofani, Elisa.(2009).Simultaneous determination of eleven quinolones in animal feed by liquid chromatography with fluorescence and ultraviolet absorbance detection.JOURNAL OF CHROMATOGRAPHY A,1216(46),8158-8164. |
MLA | Galarini, Roberta,et al."Simultaneous determination of eleven quinolones in animal feed by liquid chromatography with fluorescence and ultraviolet absorbance detection".JOURNAL OF CHROMATOGRAPHY A 1216.46(2009):8158-8164. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。