Calibration of PRISM and AVNIR-2 Onboard ALOS "Daichi" | |
Tadono, Takeo1; Shimada, Masanobu1; Murakami, Hiroshi1; Takaku, Junichi2 | |
通讯作者 | Tadono, Takeo |
来源期刊 | IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING
![]() |
ISSN | 0196-2892 |
出版年 | 2009 |
卷号 | 47期号:12页码:4042-4050 |
英文摘要 | The Advanced Land Observing Satellite [(ALOS); nicknamed "Daichi"] was successfully launched on January 24, 2006, and it continues to work very well. This paper describes the calibrations of two optical instruments onboard ALOS, which are the Panchromatic Remote-sensing Instrument for Stereo Mapping (PRISM) and Advanced Visible and Near-Infrared Radiometer type 2 (AVNIR-2). PRISM consists of three panchromatic radiometers and is used to derive a digital surface model (DSM) with high spatial resolution, which is an objective of the ALOS mission. AVNIR-2 has four radiometric bands from blue to near infrared, which are used for investigating regional environment issues such as land-use and land-cover classifications, and disaster monitoring. In this paper, we introduce the calibration and validation plan, methodologies, accuracy assessments of the standard products, image quality evaluations for PRISM and AVNIR-2, and their results. Geometric calibration is important in generating a precise DSM by a stereo pair image of PRISM. The relative geometric calibrations of both PRISM and AVNIR-2 are conducted by evaluating accuracies within one scene and evaluating sensor alignments as absolute calibration. For absolute geometric accuracies, we achieved 8.1 m for nadir-looking images and 9.3 m for forward-and backward-looking images of PRISM; we also achieved 114.2 m for AVNIR-2. PRISM is also radiometrically calibrated both relatively and absolutely. PRISM relative radiometric calibration is accomplished by using acquired images over homogeneous targets, such as oceans, deserts, ice, and snow areas, as well as nighttime observation. Simultaneously observed images with calibrated AVNIR-2 are used for absolute radiometric calibration by cross-calibration. The absolute radiometric accuracy of the PRISM nadir-looking radiometer is similar to that of AVNIR-2. |
英文关键词 | Advanced Land Observing Satellite (ALOS) calibration geometry radiometry |
类型 | Article |
语种 | 英语 |
国家 | Japan |
收录类别 | SCI-E |
WOS记录号 | WOS:000271952700014 |
WOS关键词 | VICARIOUS CALIBRATION ; ABSOLUTE CALIBRATION ; BANDS ; LANDSAT-7-ETM+ ; SALAR |
WOS类目 | Geochemistry & Geophysics ; Engineering, Electrical & Electronic ; Remote Sensing ; Imaging Science & Photographic Technology |
WOS研究方向 | Geochemistry & Geophysics ; Engineering ; Remote Sensing ; Imaging Science & Photographic Technology |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/160988 |
作者单位 | 1.Japan Aerosp Explorat Agcy, Earth Observat Res Ctr, Tsukuba, Ibaraki 3058505, Japan; 2.Remote Sensing Technol Ctr, Tsukuba, Ibaraki 3050032, Japan |
推荐引用方式 GB/T 7714 | Tadono, Takeo,Shimada, Masanobu,Murakami, Hiroshi,et al. Calibration of PRISM and AVNIR-2 Onboard ALOS "Daichi"[J],2009,47(12):4042-4050. |
APA | Tadono, Takeo,Shimada, Masanobu,Murakami, Hiroshi,&Takaku, Junichi.(2009).Calibration of PRISM and AVNIR-2 Onboard ALOS "Daichi".IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING,47(12),4042-4050. |
MLA | Tadono, Takeo,et al."Calibration of PRISM and AVNIR-2 Onboard ALOS "Daichi"".IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING 47.12(2009):4042-4050. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。