Reversed-phase chiral liquid chromatography on polysaccharide-based stationary phase coupled with tandem mass spectrometry for simultaneous determination of four stereoisomers of MK-0974 in human plasma
Xu, Yang; Musson, Donald G.
通讯作者Xu, Yang
来源期刊JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
ISSN1570-0232
出版年2008
卷号873期号:2页码:195-202
英文摘要

MK-0974 (1a), N-[(3R,6S)-6-(2,3-difluorophenyl)-2-oxo-1-(2,2,2-trifuoroethyl)azepan-3-yl]-4-(2-oxo-2,3-dihydro-1H-imidazo-[4,5-B] pyridine-1-yl)piperidine-1-carboxamide, is a novel calcitonin gene-related peptide (CGRP) receptor antagonist with two chiral centers. Direct separation of its four stereoisomers (1a-d) was achieved using a cellulose chiral stationary phase, a Chiralcel OJ-RH column (150mm x 4.6mm), under reversed-phase condition, following the extraction of 0.2 mL plasma on Oasis mu Elution HLB 96-well solid-phase-extraction (SPE) plate. The tandem mass spectrometric detection was conducted in the positive-ion mode with a turbo-ion-spray (TIS) interface using multiple-reaction- monitoring on a Sciex AP13000. Addition of ammonium trifluoroacetate to low-organic mobile phase improved detection sensitivity by more than 30-fold. The simultaneous quantification of the four stereoisomers in human plasma was validated over the ranges of 0.5-5000 nM for la and 0.5-500 nM for its three isomers (1b-d). Intraday validation, conducted with five lots of human control plasma, resulted in < 12.4% (% coefficient of variation, CV) precision and 96.3-105.4% accuracy for all four stereoisomers. Further evaluation indicated that the assay was specific, the samples were stable after three freeze/thaw cycles, the recovery was reasonable (above 65%) and no matrix effect was observed for all four isomers. Investigation on the chiral integrity of la indicated that the diastereomer 1c, inversion at azepinone-3 carbon, was the only isomer observed in the post-dose clinical samples and accounted for 2.4-5.2% of MK-0974 exposure in the circulatory system. The possibility of inversion during blood collection, plasma storage and sample preparation was ruled out, while inversion was observed in the clinical formulation accounting for similar to 0.12% of 1a in a 100-mg capsule, (C) 2008 Elsevier B.V. All rights reserved.


英文关键词Reversed-phase chiral assay CGRP receptor antagonist MK-0974 (1a) Diastereomer Enantiomer Solid-phase extraction (SPE) LC-MS/MS
类型Article
语种英语
国家USA
收录类别SCI-E
WOS记录号WOS:000260196000010
WOS关键词SCREENING APPROACH ; SEPARATION ; ENANTIOSEPARATION ; PHARMACEUTICALS
WOS类目Biochemical Research Methods ; Chemistry, Analytical
WOS研究方向Biochemistry & Molecular Biology ; Chemistry
资源类型期刊论文
条目标识符http://119.78.100.177/qdio/handle/2XILL650/158070
作者单位Merck Res Labs, Dept Drug Metab & Pharmacokinet, West Point, PA 19486 USA
推荐引用方式
GB/T 7714
Xu, Yang,Musson, Donald G.. Reversed-phase chiral liquid chromatography on polysaccharide-based stationary phase coupled with tandem mass spectrometry for simultaneous determination of four stereoisomers of MK-0974 in human plasma[J],2008,873(2):195-202.
APA Xu, Yang,&Musson, Donald G..(2008).Reversed-phase chiral liquid chromatography on polysaccharide-based stationary phase coupled with tandem mass spectrometry for simultaneous determination of four stereoisomers of MK-0974 in human plasma.JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES,873(2),195-202.
MLA Xu, Yang,et al."Reversed-phase chiral liquid chromatography on polysaccharide-based stationary phase coupled with tandem mass spectrometry for simultaneous determination of four stereoisomers of MK-0974 in human plasma".JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES 873.2(2008):195-202.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Xu, Yang]的文章
[Musson, Donald G.]的文章
百度学术
百度学术中相似的文章
[Xu, Yang]的文章
[Musson, Donald G.]的文章
必应学术
必应学术中相似的文章
[Xu, Yang]的文章
[Musson, Donald G.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。