Knowledge Resource Center for Ecological Environment in Arid Area
DOI | 10.1016/j.chroma.2007.11.091 |
Solving matrix-effects exploiting the second order advantage in the resolution and determination of eight tetracycline antibiotics in effluent wastewater by modelling liquid chromatography data with multivariate curve resolution-alternating least squares and unfolded-partial least squares followed by residual bilinearization algorithms I. Effect of signal pre-treatment | |
De Zan, M. M.1; Garcia, M. D. Gil2; Culzoni, M. J.1; Siano, R. G.1; Goicoechea, H. C.1; Galera, M. Martinez2 | |
通讯作者 | Goicoechea, H. C. |
来源期刊 | JOURNAL OF CHROMATOGRAPHY A
![]() |
ISSN | 0021-9673 |
EISSN | 1873-3778 |
出版年 | 2008 |
卷号 | 1179期号:2页码:106-114 |
英文摘要 | The effect of piecewise direct standardization (PDS) and baseline correction approaches was evaluated in the performance of multivariate curve resolution (MCR-ALS) algorithm for the resolution of three-way data sets from liquid chromatography with diode-array detection (LC-DAD). First, eight tetracyclines (tetracycline, oxytetracycline, chlorotetracycline, demeclocycline, methacycline, doxycycline, meclocycline and minocycline) were isolated from 250 mL effluent wastewater samples by solid-phase extraction (SPE) with Oasis MAX 500 mg/6 mL cartridges and then separated on an Aquasil C-18 150 mm x 4.6 mm (5 mu m particle size) column by LC and detected by DAD. Previous experiments, carried out with Milli-Q water samples, showed a considerable loss of the most polar analytes (minocycline, oxitetracycline and tetracycline) due to breakthrough. PDS was applied to overcome this important drawback. Conversion of chromatograms obtained from standards prepared in solvent was performed obtaining a high correlation with those corresponding to the real situation (r(2) = 0.98). Although the enrichment and clean-up steps were carefully optimized, the sample matrix caused a large baseline drift, and also additive interferences were present at the retention times of the analytes. These problems were solved with the baseline correction method proposed by Eilers. MCR-ALS was applied to the corrected and uncorrected three-way data sets to obtain spectral and chromatographic profiles of each tetracycline, as well as those corresponding to the co-eluting interferences. The complexity of the calibration model built from uncorrected data sets was higher, as expected, and the quality of the spectral and chromatographic profiles was worse. (C) 2007 Elsevier B.V. All rights reserved. |
英文关键词 | second order data HPLC-DAD wastewater |
类型 | Article |
语种 | 英语 |
国家 | Argentina ; Spain |
收录类别 | SCI-E |
WOS记录号 | WOS:000253006200005 |
WOS关键词 | DIODE-ARRAY DETECTION ; SEQUENTIAL INJECTION-ANALYSIS ; MASS-SPECTROMETRY ; DATA SETS ; MCR-ALS ; FLUORESCENCE ; PARAFAC ; PHOTODEGRADATION ; QUANTIFICATION ; AMOXICILLIN |
WOS类目 | Biochemical Research Methods ; Chemistry, Analytical |
WOS研究方向 | Biochemistry & Molecular Biology ; Chemistry |
资源类型 | 期刊论文 |
条目标识符 | http://119.78.100.177/qdio/handle/2XILL650/158046 |
作者单位 | 1.Univ Nacl Litoral, Fac Bioquim & Ciencias Biol, LADAQ, Catedra Quim Analit 1, Santa Fe, Argentina; 2.Univ Almeria, Fac Ciencias Expt, Dept Hidrogeol & Quim Analit, Almeria 04120, Spain |
推荐引用方式 GB/T 7714 | De Zan, M. M.,Garcia, M. D. Gil,Culzoni, M. J.,et al. Solving matrix-effects exploiting the second order advantage in the resolution and determination of eight tetracycline antibiotics in effluent wastewater by modelling liquid chromatography data with multivariate curve resolution-alternating least squares and unfolded-partial least squares followed by residual bilinearization algorithms I. Effect of signal pre-treatment[J],2008,1179(2):106-114. |
APA | De Zan, M. M.,Garcia, M. D. Gil,Culzoni, M. J.,Siano, R. G.,Goicoechea, H. C.,&Galera, M. Martinez.(2008).Solving matrix-effects exploiting the second order advantage in the resolution and determination of eight tetracycline antibiotics in effluent wastewater by modelling liquid chromatography data with multivariate curve resolution-alternating least squares and unfolded-partial least squares followed by residual bilinearization algorithms I. Effect of signal pre-treatment.JOURNAL OF CHROMATOGRAPHY A,1179(2),106-114. |
MLA | De Zan, M. M.,et al."Solving matrix-effects exploiting the second order advantage in the resolution and determination of eight tetracycline antibiotics in effluent wastewater by modelling liquid chromatography data with multivariate curve resolution-alternating least squares and unfolded-partial least squares followed by residual bilinearization algorithms I. Effect of signal pre-treatment".JOURNAL OF CHROMATOGRAPHY A 1179.2(2008):106-114. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。